Owners Manual TM Owners Manual Delu x e S y stem D-1000 Premier S y stem D-2000 Elite S y stem D-3000 F or Owner's Informa tion Owner's Informa tion Dealer Installer Model Serial Number Equi.
Owner's Informa tion Owner's Informa tion Dealer Installer Model Serial Number Equipment Pack Color Date of Deliver y Company Address Phone E-Mail W e Appreciate your business and our sincere desir e is that you receive years of pleasure and ther apy from your Dynasty Spa.
Dyna s t y Sp a s Owners Manual Dyna s t y Sp a s Owners Manual T able Of Content s Owners Information............................ Safety Instructions.............................. Basic Introductory Information........... Set-Up & Deliv er y Guidelines.
Dear Dynasty S pa Owner: Congratulations on y our purchase of a new Dynasty Spa. Y ou now possess the ultimate passpor t to tranquility - a miniature v acation at home, ready and waiting for you in y our own backyar d! W e want you to enjoy y our Dynasty Spa.
When installing and using this electrical equipment, basic safety precautions should be followed, including the follo wing: 1) RE AD AN D FOLL OW ALL I N STRUCTIONS. 2) WA RN I NG: T o reduce the risk of injury , do not permit children to use this product unless they are closely supervised at all times.
9) The causes, symptoms and affects of hyperthermia may be described as follows: 10) F or Cord Connection Units 11) Never touch or come in contact with any electrical accessory when in your spa or when your body is wet. 12) Prior to performing any service to the Spa Pack, turn off ALL power to the system at the main power sour ce breaker .
Congratulations on the purchase of y our new spa. Our purpose is to provide you with a warm and relaxing spa which incorporates a soothing water massage.
Getting R eady For Deliv er y & Set-up Of Y our New Spa Surface And Pad R equirements Balconies And Deck R equirements Access & Clearance Electrical R equirements Wiring R equirements Y our new por table spa must be placed on a uniformly firm, flat, and level surface.
Getting R eady For Deliv er y & Set-up Of Y our New Spa Wiring R equirements (Cont.) It is the customers responsibility to acquir e necessar y permits, to arrange for installation and hook up of the electrical power . Extension Cords are not to be used in conjunction with operation of the spa.
F actory Recommended G.F .C.I Load Center Wiring Note: The white neutral wire from the back of the G.F .C.I MUST be connected to an incoming line neutral. The internal mechanism of the G.F .C.I. requir es this neutral connection. The G.F .C.I. will not work without it.
Priming Pump F or Electric Packs T urn off power at the breaker It is important to make sure that all of the air is out of the equipment pack before operating. T o do this follow procedures belo w: The Power pack system is located under the wood skirt.
12 When your spa is first power ed up, it will automatically heat and maintain 100 F until you change the setting temperatur e. The current temperatur e is constantly displayed on the LED.
Y our spa will automatically filter itself twice each day . The first filter cycle will begin 1 minute after the spa is ener gized. The second filter cycle will begin 12 hours after the start of the first filter cycle. Filter duration is programmable at the topside panel for 0, 1, 2, 3, 4 or 1 2 hours.
14 When your spa is first power ed up, it will automatically heat and maintain 100 F until you change the set temperatur e. Pressing the pad a second time will cause the set temperatur e to increase or decrease depending on what direction was last chosen.
1 minute after the spa is energized. The second filter cycle will begin 12 hours after the start of the first filter cycle. Filter duration is programm- able at the topside panel for 0, 1, 2, 3, 4 or 12 hours. T o program, press the SET pad, then the JETS pad.
16 When your spa is first power ed up, it will automatically heat and maintain 100 F until you change the set temperatur e. The current temperatur e is constantly displayed on the LCD. P ress either or pad once to display the set temperature. (The temper ature is designated by a triangle in the upper left corner .
begins 1 minute after the spa is energized. The second filter cycle will begin 12 hours after the start of the first filter cycle. Filter duration is programm- able at the topside panel for FILO, FIL1, FIL2, FIL3 FIL4 or filc - 24 hours. The default filter setting is 2 hours.
If the high limit sensor detects 40 F at the heater , then the pumps and blower (if installed) automatically activ ates to pro vide freeze protection. The equipment stays on until the sensor detects 45 F at the heater . Fr eeze protection is activ ated regardless of the spa's status.
19 This valv e will allow the water flow control of neck and shoulder jets located in the trilogy / ultrassage seats. A simple turn of the pointer toward the seat will increase to the maximum output allow ed. Another turn of the point - away from the seat will decrease / turn off the neck / shoulder jets.
Single Filter Dual Filter 20 Single Filter Location F il ter Loc a tion Note: The filter should be inspected and cleaned on a monthly basis. Dual Filter Location.
Filtration starts as soon as flow is steady through the filter . The filter car tridge remo ves the dir t from the spa water , the accumulated dir t causes flow r esistance. A dir ty car tridge will decrease flo w and may cause spa not to heat properly .
2) PRO TECT PL US - This prev ents a calcium build up. Use 2 oz. on a weekly basis. 3) CA L CI UM BOOSTE R ( If Needed ) - Calcium booster treats the water if low calcium hardness is a problem in y our area. It will help prevent equipment corrosion and foaming by r aising the spa's water hardness level to an acceptable r ange of 120 ppm.
W ater T esting Balance Spa water must have the corr ect chemical balance. Unbalanced water can irritate eyes, corrode the equipment, leav e mineral deposits, and decrease the effectiveness of the sanitizer . Balanced water means establishing proper balance among T otal Alkalinity , pH, Calcium Hardness and T otal dissolved solids.
An Overview Filter Cleaning Surface Cleaning Surface Protection W ater Balance Sanitizing Mineral Pr otection F oam Control Aromatic Control Monthly - F or Equipment Protection As Needed CA L CI UM BOOSTE R ( If Needed ) - Calcium booster treats the water if low calcium hardness is a pr oblem in your area.
An Overview Skin Conditioning Algae Contr ol As Needed (cont.) T o prev ent dry skin, pour S KI N SOF TN E R directly into the spa. It smoothes and moisturizes. Do not leave your water tr eatment products outside. If they are subject to extreme heat or cold, their effectiv eness can be impaired making them unusable.
T urn off power at the breaker . Hook up a garden hose to the hose bib located in spa equipment area or on the exterior side cabinet. When water begins to drain out of the hose, be sure to dr ain the water to a convenient place. Note: Be sure that hose is on a downwar d grade to properly drain spa.
In areas of the country where the temper atures drops below 32 degr ees F , it is impor tant to follow these dir ections 1) If the spa is not going to be used, drain completely and store in gar age or some type of storage facility . Be sure all water is remov ed.
PROTECT YOUR COVER Pr oper Maintenance For Y our Dynasty Spa Co ver 2) Splash cool tap water on the hardwar e to free them if they become frozen shut. WD-40 will keep the lock free, but apply carefully because it can damage the cabinet finish. 3) We recommend a good tr eatment with V inyl Conditioner before your first snow or ice.
No heat or heat too low S pa Lights won't come on Pump will not prime Jets won't come on Probable Cause #1 Action Dir ty Filter Clean Filter / Pull Filter and try running without filter Probable Cause #2 Action Probable Cause #3 Action Breaker at house off .
Lo w water flow S pa is leaking Motor does not run Motor runs hot Probable Cause #1 Action Dir ty Filter Remo ve filter cartridge and clean. Probable Cause #2 Action Probable Cause #3 Action Closed gate valv es or blocked lines. Open all gate valv es.
Air Blower The air blower supplies air to the jets cr eating a hydro massage action Air Loop A back up system for the check valv e, prevents water from entering air blo wer Air V enturi Mounted on the.
pH Stands for "Potential for H ydrogen" This is the term used to describe the acid (low pH) or alkalinity (high pH) condition of the water . The ideal pH for spa water is 7.5 Skimmer This is the circular outlet at the water level. The skimmer remo ves surface debris to the filter .
Sp a Models Det ail Reference Char t Baron Camelot Duchess Dynamo II Dynamo III Ecstasy Emperor Gallant Jester Knight Lancelot Luxor Monarch Princess Renaissance T uscan Ultima V enetian Windsor 9, 21.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dynasty Spas D-2000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dynasty Spas D-2000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dynasty Spas D-2000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dynasty Spas D-2000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dynasty Spas D-2000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dynasty Spas D-2000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dynasty Spas D-2000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dynasty Spas D-2000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.