Manuale d’uso / di manutenzione del prodotto BRISK AIR 579 SERIES del fabbricante Dometic
Vai alla pagina of 12
1 INST ALLA TION INSTRUCTIONS REVISION: Form No. 3109395.066 8/07 (Replaces 3109395.058) (French 3109660.063) ©2007 Dometic Corporation LaGrange, IN 46761 INST ALLA TION INSTRUCTIONS Lire et comprendre ce manuel avant de procéder à l’installation, à des réglages, de l’entretien ou des réparati ons.
2 INST ALLA TION INSTRUCTIONS SAFETY INSTRUCTIONS This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
3 INST ALLA TION INSTRUCTIONS SPECIFICA TIONS 120V AC, 60 HZ., 1PH. 12 AWG Copper up to 24’ * For wire lengths over 24 ft. consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements.
4 INST ALLA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS 1. PRECAUTIONS Improper insta llation may damage equipment/could endanger life, cause serious injury and/or property damage. A. Read Installation and Operating Instructions carefully before attempting to start your air conditioner installa- tion.
5 INST ALLA TION INSTRUCTIONS C. AFTER LOCA TION HAS BEEN SELECTED: 1. Check for obstructions in the area where air condi- tioner will be installed. 2. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement.
6 INST ALLA TION INSTRUCTIONS It is the responsibility of the installer of this air condi- tioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. W ater standing around the air conditioner ma y lea k int o the inte ri or caus in g da mage to the pro du ct and the RV .
7 INST ALLA TION INSTRUCTIONS 3. A 3/8” diameter hole will be needed to route the cable through the wall. B. CONTROL CABLE INST ALLA TION A 4-conductor control cable must be routed from the roof opening to the Comfort Control Center ™.
8 INST ALLA TION INSTRUCTIONS 6. DISCHARGE DUCT & CEILING TEMPLA TE INST ALLA TION A. Remove the air box and mounting hardware from their carton. The upper duct is shipped inside the lower duct which is part of the ceiling template. B. Remove the upper duct from the ceiling template and locate it over the blower discharge.
9 INST ALLA TION INSTRUCTIONS TROL KIT A. If your installation included the optional electric heat kit, install it at this time. Follow the instructions with the heat package for its installation procedure. B. T erminate the 4-conductor control cable(s) protruding into the 14-1/4” x 14-1/4” (±1/8”) roof opening.
10 INST ALLA TION INSTRUCTIONS 8. SYSTEM CONFIGURA TION, RESET & CHECKOUT Nowthat thesystem isinstalled, itis necessaryto congurethe elec - tronics and check all operations. Refer to the Operating manual for a description of the air conditioner operation.
1 1 INST ALLA TION INSTRUCTIONS FIG. 16 T wo Zone Conguration FIG. 15 9. AIR BOX INST ALLA TION A. Remove return air grille from air box by pulling in on half- roundngercatches. B. Hold air box up to ceiling template and install three (3) #10 x 3/8” (C) screws at air box mounting point.
12 INST ALLA TION INSTRUCTIONS AIR CONDITIONING UNIT A. (4) 1/4” — #20 x 7” bolts B. (4) #8 x 5/8” long sharp point wood screws C. (7) #10 x 3/8” blunt point tapping screws D.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dometic BRISK AIR 579 SERIES è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dometic BRISK AIR 579 SERIES - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dometic BRISK AIR 579 SERIES imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dometic BRISK AIR 579 SERIES ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dometic BRISK AIR 579 SERIES, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dometic BRISK AIR 579 SERIES.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dometic BRISK AIR 579 SERIES. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dometic BRISK AIR 579 SERIES insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.