Manuale d’uso / di manutenzione del prodotto 620525.331 del fabbricante Dometic
Vai alla pagina of 16
620515, 620525, 620526, 630515 & 630516 Installation Instructions 1 Important: These Instructions must stay with unit. Owner read carefully. REVISION: Form No. 3309083.032 9/07 (Replaces 3309083.024) (French 3309084.030) ©2007 Dometic Corporation LaGrange, IN 46761 C U S INST ALLA TION INSTRUCTIONS Models 620515.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 3 620515.331 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.5 KW/5.0 KW 620515.336 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 4 A . Precautions Improper installation may damage equipment, could endanger life, cause serious injury and/ or property damage. 1. Read Installation and Operating Instructions care- fully before attempting to start your air conditioner installation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 5 It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 6 It is the responsibility of the installer to insure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof structural or ceiling damage due to improperly insulated, sealed or collapsed ductwork.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 7 These items must be determined in conjunction with the Air Distribution System and Sizing and Design Require- ments listed in the chart on page 6. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/ 8").
620515, 620525, 620526, 630515 & 630516 Installation Instructions 8 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 9 Important: RJ-11-6C4P connectors must be installed as shown in FIG. 8A, 8B & 8C. 3. Comfort Control Center TM Installation a. Carefully remove the base plate from the Com- fort Control Center TM .
620515, 620525, 620526, 630515 & 630516 Installation Instructions 10 CAUTION If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 11 Improper installation and sealing of divider plate will cause the compressor to quick cycle on the cold control. This may result in fuse or circuit breaker opening and/or lack of cool- ing.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 12 e. Use Aluminum foil tape (not supplied) to seal the ends of the foam divider to the sides of the opening. Make sure the area behind the flange on the ceiling template is sealed.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 13 If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 14 Installing unit with 3308120 Genesis Air Filtra- tion System Return Air Kit. For 3105007 or 3105935 Return Air Kit, see page 14. 1. Install the slider in the return air cover and raise it to the ceiling template.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 15 J . System Configuration, Reset & Check Out Now that the system is installed, it is necessary to check all operations and then configure the electronics. Refer to the Operating manual for a description of the air conditioner operation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 16 REAR REM O TE SENS O R ( R e qui re d wi t hS e c on d Ai r C on di t i oner) REAR REM O TE SENS O R ( R e qui re d wi t h S e .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dometic 620525.331 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dometic 620525.331 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dometic 620525.331 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dometic 620525.331 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dometic 620525.331, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dometic 620525.331.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dometic 620525.331. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dometic 620525.331 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.