INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS: BF33ST/DX BF39ST/DX BF45ST/DX 7206350200REV06.
CONTENTS PAGE 1 Listings and Code Approvals PAGE 1 Model Specifications PAGE 1 Step-by-Step Installation Section A P A G E 2 F r a m i n g Section B PAGE 2 Recommended Power Supply Wire Specifications.
LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in acco rdance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated ele ctric ro om heaters.
WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING Dimensions This firepl ace is a zer o clear ance des ign. No comb ustibl es can be placed on the top surface of the fireplace.
VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION D: MAIN POWER WALL SWITCH WIRING OPTI ONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires to tal) from the power supply panel to the main switch wall box.
240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 8 FIREPLACE JUNCTION BO X 240 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH RED – L2 GROUN.
MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires tota l) from the power supply panel to the main switch wall box.
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM 10 FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G.
MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWIT.
SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D.
HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 14 FIREPLACE JUNCTION BOX RED – 2 WALL SWITCH RED – 1 GROUND - G.
WALL MOUNTED THERMOSTAT WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermo stat wall box to the junction box on the unit.
WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 16 FIREPLACE JUNCTION BOX WALL THERMOSTAT RED – 1 GROUND - G RED – 2 CONNECT GROUND T.
FLAME OVERRIDE SWITCH WIRI NG FOR 120/240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater indepen dent of the flame . NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D.
FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLATION FIREPLACE JUNCTION BOX BLUE – 4 WALL SWITCH .
WIRING DIAGRAM LOWER SECTION 19 BLACK WHITE BROWN CITOR BYPASS HARNESS LOWER HARNESS WHITE ORANGE FROM TOP BROWN FROM TOP RED FROM TOP BLUE (3) MOTOR FLICKER TWIST-TIE RED RED 2 1 RED (L2) HEATER SWIT.
WIRING DIAGRAM UPPER SECTION 20 CUT-OUT M ELEMENT #2 ELEMENT #1 2 6 4 1 5 3 BLOW ER WH EEL BLW. MOTOR BROWN ORANGE RED (CUT-OUT LONG WIRE) BLK YLW BLK BLK YLW BLK BLK BLK YLW RED (CUT-OUT SHORT WIRE).
WIRING SCHEMATIC 21.
1367 Industrial Road Cambridge, Ontario Canada, N1R 7G8 1-888-DIMPLEX 1-888-346-7539 Approved for use in the United States an d Can ada.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dimplex BF39ST/DX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dimplex BF39ST/DX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dimplex BF39ST/DX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dimplex BF39ST/DX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dimplex BF39ST/DX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dimplex BF39ST/DX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dimplex BF39ST/DX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dimplex BF39ST/DX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.