Manuale d’uso / di manutenzione del prodotto MSB900L del fabbricante DIGITAL-LOGIC
Vai alla pagina of 66
Detailed Technical US ER M ANUAL FOR: 3.5”-SBC MSB900/L Nordstrasse 11/F CH- 4542 Luterbach Tel.: ++41 (0)32 681 58 00 Fax: ++41 (0)32 681 58 01 Email: support@digitallogic.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 2 For internal use only: File: MSB900_Detailed_V1.0 Path: R:HANDBUCHMS BMSB900MS B900_Detailed_V1.0 .doc COPYRIGHT 2008 BY DIGITA L-LOGIC A G This publication is protected by c opyright and all r ights are reserved.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 3 Table of Contents 1. Preface ....................................................................................................................... 5 1.1. Tr adema rks .....................
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 4 5.6.3. W atchdog ................................... ................................ ................................ ................................ 28 5.6.4. ROM-BIOS Sockets ...........
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 5 1. P REF A C E The inf ormation contain ed in this m anual has been carefull y ch ecked and is believed to be accurate; it is subject to c hange without notice. Product adva nces m ean that s ome specifications may have changed.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 6 1.5. Recycling Informati on All com ponents within this product f ulfill the requirem ents of the RoHS (Restrictio n of Hazardous Substanc es Directive). The pro duct is soldered with a lead f ree process .
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 7 1.8. Explanation of Symbols CE Conformity This symbol indica tes that the pro duct described in this manual is in compliance wi th all ap- plied CE standards.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 8 1.9. Applicable Docume nts and Sta ndards The f ollowing p ublications are used in c onjunction with this manual. W hen any of the referenced specifica- tions are supersede d b y an approved r evision, that re vision s hall app ly.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 9 Smart Battery Dat a Specification Revision 1.1, Dec ember 11, 1998. www.sbs-f orum.org System Managem ent Bus ( SMBus) Specif ication Vers ion 2.0, Augus t 3, 2000 C opyright © 1 994, 1995, 1998, 2000 Duracell, Inc.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 10 RoHS is often refer red to as the "le ad-free" directive but it restricts the use of the following substanc es: Lead Mercury Cadmium Chromium VI PBB and PBDE The max imum allowable concentrat ion of an y of the above m entioned substanc es is 0.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 11 1.12. Swiss Quality 100% Made in Switzerland DIGITAL-LOGIC is a m ember of "Swiss-Label" This product was not m anuf.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 12 2. O VERVIEW 2.1. Standard Features of the MSB9 00/L The MICROS PACE 3.5”-S BC is a miniaturized m odular device incorporating the major elem ents of a PC/ AT compatible com puter.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 13 2.3. MSB900 Block Diagram.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 14 2.4. MSB900/MSB90 0L specification s CPU Specification CPU GEODE LX900 CPU Core Suppl y 1.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 15 Mass Storage Specification FD Floppy disk interface not supported HD E-IDE interfac e, AT-type, for m ax. 2 hard disk s, 44pin connector, for 1.3, 1.8 and 2. 5" hard disk with 44 pins IDE Standard AT Interfa ces: Specification Name FIFO IRQs Addr.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 16 Operating Environmen t Specification Relative hum idity 5-90%, non-condens ing Vibration 5-2000Hz, 0.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 17 2.7. Dimensions & Dia grams 2.7.1. MSB900/L Board / Version Unit: Tolerance: Dat e / Author MSB900/L mm (m illimeter) + / - 0.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 18.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 19.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 20.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 21 2.7.2. MSB800CON Part Nr 802205 Board / Version Unit: Tolerance: Dat e / Author MSB800CON mm (m illimeter) + / - 0.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 22 2.8. MSB900/L Incompa tibilities to a stan dard PC/ AT None. 2.9. Related A p plica tion Notes Application No tes are av ailable at http://www.digit allogic.com support, or on an y DIGIT AL-LOGIC Application CD.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 23 2.11. Battery-Lifetime Battery specs: Low est temp. -40° C Nominal temp. +20° C Highest temp. +85° C Manufacturer: pba T y pe: ER10280 Capacity versus T emp: 10uA 420mAh 400mAh 350m Ah Voltage versus T emp.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 24 4. BIOS H IST OR Y This BIOS histor y is for the MSB90 0/L. This BIOS histor y is not fo r the followin g products: MSEP900, MSM9 00, SM900 Version: Date: Status: Modifications: 1.23 02.2007 Initial Relea se - - - - - - - Note… This pr oduct has a unique BIOS ver sion.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 25 5. D ET A I LED S YSTEM D ES CRIPTION This s y stem configuration is based on the ISA architecture. Chec k the I/O and m em ory map in this chapter. 5.1. Power Require ments The power is connec ted through the wide-range power connector.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 26 5.3. CPU, Boards an d R A M s 5.3.1. CPUs of this MIC ROSPA CE Product Processor: T ype: Clock: GEODE LX900 National 600 MHz 5.3.2. Numeric Coproces sor It is integrated in th e LX900 CPU. 5.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 27 5.4.3. Serial Ports CO M1-COM2 The serial c hannels are fully com patible with 16C 550 U ARTS. COM1 is the primar y s erial por t, and is su p- ported b y th e boar d's ROM-BIOS as the PC-DOS 'CO M1' de vice.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 28 5.6. Timers and Cou nters 5.6.1. Programmable Timers An 8 253 compatible timer /counter device is a lso included in th e board's ASIC device. This device is utilized in prec isel y the same manner as in a standard AT implementation.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 29 5.6.4.1. Standard BIOS RO M Device: F W H Map: E0000 - FFFFFh Core BIOS 128k C0000 - C7FFFh VGA BIOS 32k CC000 - CFFFFh FREE 5.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 30 CMOS Map Location De scription 00h Time of day (seconds) specified in BCD 01h Alarm (seconds) specified in BCD 02h Time of day (minutes) s.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 31 CMOS Map continued... Location Description 0Eh CMOS Location for Bad CMOS and Checksum Flags Bit 7 = Flag for CMOS Lost Power 0 = Power OK.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 32 CMOS Map continued... Location Description 15h Base Memory Size (in kB) - Low Byte 16h Base Memory Size (in kB) - High Byte 17h Extended M.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 33 CMOS Map continued... Location Description 22h Byte 3 Bits 7-6 = Res erved Bits 5-0 = Uppe r 6 bits of W rite Precompensation 23h Byte 4 B.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 34 CMOS Map continued... Location Description 33h Base Memory Installed Bit 7 = Flag for Memory Size 0 = 640kB 1 = 512kB Bits 6-0 = Res erved 34h M i nor CPU Revision Differentiates CPUs within a CPU type (i.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 35 5.8.1. EEPROM Memory for Setup The EEPROM is used for setup an d configuration data, stored as an alternative to the CMOS-RTC. Option- ally, the E EPROM setup driver ma y update the CMO S RT C, if the battery is runn ing down a nd the check sum error would appe ar and stop the s ystem.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 36 5.9.2. System I/O map The following tabl e de tails the legac y I/O r ange for 0 00h t hrough 4FFh. Eac h I/O location has a read/ write (R/W) capability. Note the follow ing abbreviatio ns: --- Unknown or can not be determ ined.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 37 I/O Map Continued… I/O Addr. Function Size R/W Comment If KEL Memory Offset 100h[0] = 1(Emulation- Enabled bit). 060h Keyboard/Mouse - Data Port 8bit Yes If MSR 5140001Fh[0] = 1 (SNOOP bit) and KEL Memory Offset 100h[0] = 0 (Emulation- Enabled bit).
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 38 I/O Map Continued… I/O Addr. Function Size R/W Comment 0CCh Master DMA Address - Channel 7 8bit Yes 16 bit values in two transfers. 0CDh No Specific Usage 8bit --- 0CEh Master DMA Counter - Channel 7 8bit Yes 16bi t values in two transfers.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 39 I/O Map Continued… I/O Addr. Function Size R/W Comment 3F1h Flopp y Status R B 8bit RO First Floppy. 3F2h Flopp y Digital Out 8bit Shw@ First Floppy. 3F3h No Specific Us age 8bit --- 3F4h Flopp y Cntrl Status 8bit RO First Floppy.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 40 6. VGA 6.1. VGA/LCD Contr oller of the Ge ode LX900 • Highly integrated flat panel and C RT GUI Acc elerator & Multim edia Engine, P.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 41 7. V IDEO I NPUT The MSB900 conta ins a low-cost video inp ut port. It c onsist of LX900’s video input port (VIP) and t he ext er- nal f ram e grabber chip SAA7111A. T his port is c apable of digitizing a CVB S video signal with 15 f ram es per second at a r esolution of 352x288bits.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 42 Top view of the MSB900/L.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 43 Bottom v iew of the MSB900/L.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 44 X1 Power Supply Pin Signal 1 (Shield) Po wer supply 8-30 V 2 NC 3 Power su pply GND X14 V ideo IN Pin Signal Pin Signal 1 CVB S 2 GND.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 45 X15 Operator Panel / Flat Panel (b ottom side) X15 is intended to be used internal ly to at tach a n ope rator panel. Some signa ls m ay not be present or are shared with other connecto rs.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 46 X15 Reverse Pin Configuratio n MSB900 LVD S X15 (on comp onent side) Attention! W hen X15 is soldered on the c omponent side, a different pin num bering schem a must be applied . Odd and even pin number s are swapped.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 47 X31 Keyboard P S/2 and M ouse Utility Connector Connector and Adapter Mini- DIN PS/2 (6 PC) Remarks Shield Sh ield KEYBOARD DATA 1 GND 3 V.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 48 X39 Serial Port COM 2 Header onboard D-SUB conne ctor Signal Pin 1 Pin 1 DCD Pin 2 Pin 6 DSR Pin 3 Pin 2 RxD Pin 4 Pin 7 RTS Pin 5 Pin 3 T.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 49 X52 USB UDOC ( not assembl ed ) Pin Signal Pin Si gnal 1 VCC 6 NC 2 NC 7 GND 3 USB- P2- 8 NC 4 NC 9 NC 5 USB- P2+ 10 NC Attention! X52 for USB-DOC-Flash drives are onl y for OEM use. T he connector is not assem bled.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 50 X61 Serial Port COM 1, Parallel Port L PT1 Header onboard D-SUB conne ctor Signal Pin 1 Pin 1 DCD Pin 2 Pin 6 DSR Pin 3 Pin 2 RxD Pin 4 Pi.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 51 X101 PCI-104 BUS Int erface Pin A B C D 1 GND/5.0V KEY2 Reserve d +5 AD00 2 VI/O AD02 AD01 +5V 3 AD05 GND AD04 AD03 4 C/BE0* AD07 GND AD06 5 GND AD09 AD08 GND 6 AD11 VI/O AD10 M66EN 7 AD14 AD13 GND AD12 8 +3.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 52 X230 JT A G -Port Pin Signal Pin Signal 1 T CK 2 T MS 3 T DI 4 T DO X301 VG A Monitor (CRT-Signals) 15pins High-Densit y DSub Pin S ignal .
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 53 9. J UMPER L OC A TIONS ON THE B O ARD The f ollowing figure shows the location of a ll jum per bloc ks on th e MSB9 00/L boa rd. The num bers shown in this f igure are silk screened on the board so that the pins can easily be located.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 54.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 55 10. C A BLE I NTERF A CES 10.1. The Hard Disk Cable 44 pin IDT Term inal for Dual Row ( 2.00mm grid) and 1.00mm f lat cable; 44pins = 40 pins signal and 4pi ns power. 1 1 2 43 43 44 44 39 39 40 40 2 Max.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 56 10.2. The COM1/LPT Serial Interface Cable Term inal for dual row 2mm grid and 1mm flat cable.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 57 10.3. The COM2 Serial Interface Cable DT term inal for dual row 0.1" (2.54m m grid) and 1.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 58 11. T HE RMAL S PECIFIC A TIONS 11.1. Thermal Analysis for Case In tegration The MSB900/L has a unique therm al design.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 59 12. A SSEMBL Y V IEWS 12.1. MSB900/L.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 60.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 61 12.2. Mechanical Dimensions MSB900 Version Unit: mm (millimeter) Tolerance: +/- 0.1mm Date: 28.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 62 13. PXE-B OOT AND PXE-S ETUP IN THE BIOS PXE Protocol PXE is defined on a foun dation of industr y-standard Internet protoco ls and services that are widel y d eplo yed in the industry, namely T CP/IP, DHC P, and TFT P.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 63 BIOS-Setup Scre en with the LAN- BOOT (PX E) DISABLE / ENABLE m enu: After ENABLING th e LAN-Boot, th e Password m ust be entered. The Password m ust be requested with the PX E-licence order form on the follo wing page.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 64 14. PXE-L ICENSE O RDER The PXE-Function must be licensed before it can be enable d. To order, f ill out and sign this form ; r eturn to the fax num ber below. This f orm may be printed out separately f rom the digital cop y of this manual on t he Product CD.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 65 15. I NDEX 1 10/100 BASE-T Interface 47 A Addressing PCI D evices 23 Application Notes 16, 22 B Battery-Lifetim e 23 BIOS CMOS 29 BIOS His.
DIGITAL-LOGIC AG M SB900/L Detailed T echnical Manual V1.0 66 RoHS Comm itment 9 ROM-BIOS 28 RTC 28 S Safety Precautions 9 Schematics 59 Serial Interface Ca ble 56, 57 Serial Port COM1 50 Serial Port .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il DIGITAL-LOGIC MSB900L è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del DIGITAL-LOGIC MSB900L - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso DIGITAL-LOGIC MSB900L imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul DIGITAL-LOGIC MSB900L ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il DIGITAL-LOGIC MSB900L, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del DIGITAL-LOGIC MSB900L.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il DIGITAL-LOGIC MSB900L. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo DIGITAL-LOGIC MSB900L insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.