Save this manual for future reference. BLUE FLAME VENT -FREE PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL 10,000 Btu/Hr Thermostatically- Controlled Models VP1000BT A WARNING.
2 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly.
3 104266 OWNER’S MANUAL PRODUCT IDENTIFICA TION PRODUCT FEA TURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
4 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
5 104266 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.
6 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 WARNING: Rework work- sheet, adding the space of the adjoining unconfined space.
7 104266 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" Clearance From Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INSTALLING HEATER TO WALL Marking Screw Locations 1.
8 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1.
9 104266 OWNER’S MANUAL Figure 13 - Gas Connection * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design- certified equipment shutoff valve from your dealer.
10 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system.
11 104266 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Remove fr ont panel (see Figure 10, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights.
12 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® GRH/OV 008 BAD PILOT/LP INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern.
13 104266 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service per- son should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
14 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® TROUBLESHOOTING Continued REMEDY 1. Clean burner orifice (see Cleaning and Maintenance , page 12) or replace burner orifice 2. Replace burner orifice 3. Contact local propane/LP gas company 1.
15 104266 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
16 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® 12-2 12-1 ODS/PILOT ILLUSTRA TED PA R T S BREAKDOWN 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19 VP1000BT A.
17 104266 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
18 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® SPECIFICA TIONS VP1000BTA Btu(Variable) 5,000/10,000 Type Gas Propane/LP Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water) 14" Max. / 11" Min.
19 104266 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa VP1000BTA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa VP1000BTA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa VP1000BTA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa VP1000BTA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa VP1000BTA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa VP1000BTA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa VP1000BTA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa VP1000BTA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.