350 SIDE PV 026 Heater Sizes: 350,000 and 600,000 Btu/Hr Models: SB350D and SB600D ARL LOGO G 004 ® OWNER’S MANUAL HIGH PRESSURE POR T ABLE FORCED AIR HEA TERS 600 SIDE PV 027 IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater.
2 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly.
3 106029 OWNER’S MANUAL PRODUCT IDENTIFICA TION Upper Shell Power Cord Thermostat Fuel Cap Fuel Tank Hot Air Outlet Lower Shell Power Cord Fuel Tank Hot Air Outlet Upper Shell Motor and Pump Assembl.
4 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in: • clogged fuel .
5 106029 OWNER’S MANUAL OPERA TION To Start Heater 1. Follo w all ventilation and safety infor - mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Set thermostat dial to desired tempera- ture. Note: Thermostat setting must be higher than surrounding air temperature.
6 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR PREVENT A TIVE MAINTENANCE SCHEDULE Item Fuel tank Filler neck screen Fuel filter assembly (Fuel tank) Fuel filter lin.
7 106029 OWNER’S MANUAL OBSERVED PROBLEM WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
8 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR OBSERVED PROBLEM Heater will not ignite, but motor runs for a short period of time. 1. A) Add fuel to tank B) Check fuel tank for bubbles of water in bottom. If found, remove fuel (see Storing, T ransporting, or Shipping , page 5).
9 106029 OWNER’S MANUAL OBSERVED PROBLEM Heater ignites, but flame-out control shuts off heater after a short period of time Heater burns, but puffs of smoke can be seen Heater does not burn steady Heater burns with odor Heater smokes continuously 1.
10 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Figure 7 - Spark Plug Removal Spark Plug Wire Spark Plug Burner Head Spark Plug 1. Remove upper shell (see column 1). 2. Remove spark plug wire from spark plug (see Figure 7).
11 106029 OWNER’S MANUAL Pump (Procedure if Pump is Binding) 1. Remove upper shell (see page 10). 2. Loosen hex screw on flange clamp at rear of motor with 5/16" nut-driv er (see Figure 11). 3. T urn fan with hand (see Figure 12). 4. If fan turns freely , tighten screw on flange clamp.
12 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Fuel Filter Fuel Lines Fuel Filters A. T ank Fuel Filter 1. Disconnect fuel lines from pump and pump fuel filter assembly with 7/16" wrench (see Figure 15). 2. Carefully pry fuel filter loose from fuel tank with flat end of screwdr iver .
13 106029 OWNER’S MANUAL SPECIFICA TIONS 350,000 Btu/Hr 600,000 Btu/Hr Output Rating (Btu/Hr) 350,000 600,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gallons) 30 36 Fuel Consumption (Gallons Per Hr) 2.5 4 Electric Requirements 120V/60 Hz 120V/60 Hz Amperage (Normal Run) 7.
14 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN SB350D 350,000 BTU/HR 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25 .
15 106029 OWNER’S MANUAL REF. NO. PART NO. DESCRIPTION QTY. 1 099329-02 Upper shell model SB350D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 15 3 M50542-01 Combustion chamber & shield 1 4 M.
16 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN SB600D 600,000 BTU/HR 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 .
17 106029 OWNER’S MANUAL P ARTS LIST SB600D 600,000 BTU/HR REF. NO. PART NO. DESCRIPTION QTY. 1 099329-04 Upper shell model SB600D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 28 3 M50543-01 Com.
18 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR 4 9 8 7 6 5 3 1 2 REF NO. PART NO. DESCRIPTION QTY. 1 M10908-2 Screw, #6-32 x 3/8" (350,000 Btu/Hr Only) 2 2 09922.
19 106029 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include Model number and Serial number. W ARRANTY AND REP AIR SERVICE PARTS AND SERVICE UNDER WARRANTY Should your heater require service, return it to your nearest authorized service center.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa SB600D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa SB600D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa SB600D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa SB600D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa SB600D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa SB600D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa SB600D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa SB600D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.