Manuale d’uso / di manutenzione del prodotto R 15 E UK del fabbricante Desa
Vai alla pagina of 14
IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
2 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels.
3 104975 OWNER’S MANUAL PRODUCT IDENTIFICA TION Lower Shell Side Cover Fuel Tank Upper Shell Hot Air Outlet Handle Fan Guard Air Filter End Cover Fuel Cap Figure 1 - Model R 15 E UK Power Cord Flame-Out Control Reset Button ON/OFF Switch UNP ACKING 1.
4 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
5 104975 OWNER’S MANUAL OPERA TION Figure 3 - Flame-Out Control Reset Button WARNING: Review and un- derstand the warnings in the Safety Information section. They are needed to safely operate this heater. Follow all local codes when using this heater.
6 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. POSSIBLE CAUSE 1. W rong pump pressure 2. Dirty air output, air intake, and lint filters 3.
7 104975 OWNER’S MANUAL SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws and lock washers along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell of f. 3. Remove fan guard.
8 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® SER VICE PROCEDURES Continued Figure 8 - Pressure Gauge Plug Removal Figure 9 - Adjusting Pump Pressure Pump Pressure Model (PSI/Bar) 50,000 Btu/Hr 4.9/0.338 PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover .
9 104975 OWNER’S MANUAL NOZZLE 1. Remove upper shell (see page 7). 2. Remove fan (see page 7). 3. Remove fuel and air line hoses from burner head. 4 . Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench.
10 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® 1 2 4 3 5 6 7 8 10 11 12 12 14 15 17 20 18 19 21 21 24 28 29 30 31 32 34 38 37 11 13 9 33 35 36 42 43 39 40 23 44 11 41 45 26 25 16 22 27 ILLUSTRA .
11 104975 OWNER’S MANUAL P ARTS LIST R 15 E UK This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
12 104975 POR T ABLE FORCED AIR HEA TER R 15 E UK ® WIRING DIAGRAM R B C D A B 1 1a 230 V~/50 Hz Green-Yellow Green-Yellow Ignitor Photocell Spark Plug Flame-Out Control Reset Button White White Whit.
13 104975 OWNER’S MANUAL EC CONFORMITY DECLARA TION DESA Europe B.V . Innsbruc kweg 144, 3047 AH P ostb us 11158 3004 ED Rotterdam Holland Manufacturer: DESA International, Inc.
W ARRANTY AND REP AIR SERVICE DESA International warrants new Products sold by it to be free from defects in material or workmanship for a period of one year after date of delivery to the first user .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa R 15 E UK è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa R 15 E UK - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa R 15 E UK imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa R 15 E UK ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa R 15 E UK, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa R 15 E UK.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa R 15 E UK. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa R 15 E UK insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.