Manuale d’uso / di manutenzione del prodotto PCVDR24 RGA del fabbricante Desa
Vai alla pagina of 20
NA TURAL GAS LOG WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 901747 VENTED NA TURAL GAS LOGS 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP , using the GA9050 or GA9150 pilot kit.
3 901747 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification OPTIONAL PRODUCT FEA TURES ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSION An optional valve/safety pilot kit with a piezo ignitor is available for this appliance.
4 901747 VENTED NA TURAL GAS LOGS PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation . All spaces in homes fall into one of the three following ventilation classifications: 1.
5 901747 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 901747 VENTED NA TURAL GAS LOGS AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building Outlet Air Ventilated Attic Out.
7 901747 OWNER’S MANUAL INST ALLA TION WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated.
8 901747 VENTED NA TURAL GAS LOGS INST ALLA TION Continued WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
9 901747 OWNER’S MANUAL INST ALLA TION Continued Figure 7 - Checking Gas Joints HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly Note: Be sure all pipe threaded connections are tight, and have thread compound to pre- vent leaks. 1. Determine which side the gas line will be coming into the fir eplace.
10 901747 VENTED NA TURAL GAS LOGS 2. Attach the pilot gas line to the pilot out- let of the gas control v alve and tighten. Connect the thermocouple to the rear of the gas control valv e. See Figure 12. Do not overtighten. If using propane/LP g as, see Changing Pilot Orif ice, page 11.
11 901747 OWNER’S MANUAL TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections. WARNING: Never check for gas leaks with open flame. 2. Light the b urner with the shut-off v alve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 12).
12 901747 VENTED NA TURAL GAS LOGS LIGHTING INSTRUCTIONS OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
13 901747 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
14 901747 VENTED NA TURAL GAS LOGS OBSERVED PROBLEM When ignitor button is pressed, there is no spark at pilot (GA9050 Only) When ignitor button is pressed, there is spark at pilot but no ignition (GA.
15 901747 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
16 901747 VENTED NA TURAL GAS LOGS ILLUSTRA TED PA R T S BREAKDOWN MODEL PCVDR24 3 13 1 8 6 4 2 10 7 20 5 9 9 14 15 19 16 21 17 18 11 12.
17 901747 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual. MODEL PCVDR24 KEY PART NO. NUMBER DESCRIPTION QTY.
18 901747 VENTED NA TURAL GAS LOGS ACCESSORIES Purchase these logset accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for infor- mation. You can also write to the address listed on the back page of this manual.
19 901747 OWNER’S MANUAL Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department FBD 1349 Adams St.
LIMITED WARRANTY COMFORT FLAME ® VENTED GAS LOGS DESA International warrants this product to be free from defects on burner system for three (3 ) years and logs for a lifetime f rom the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa PCVDR24 RGA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa PCVDR24 RGA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa PCVDR24 RGA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa PCVDR24 RGA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa PCVDR24 RGA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa PCVDR24 RGA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa PCVDR24 RGA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa PCVDR24 RGA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.