Manuale d’uso / di manutenzione del prodotto CGCFTN del fabbricante Desa
Vai alla pagina of 28
Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE NA TURAL GAS COMP ACT FIREPLACE Shown with Optional Cabinet Mantel/Hearth Base Accessory 14,000 to 26,0.
2 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN IMPORTANT: Read this owner ’ s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
3 107035 OWNER’S MANUAL 15. Operating fireplace above elevations of 4,500 feet could cause pilot outage. 16. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger). 17. Provide adequate clearances around air openings.
4 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN ASSEMBL Y WARNING: Always have branch support and screen in place before operating fireplace.
5 107035 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 107035 OWNER’S MANUAL Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor.
8 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN INST ALLA TION WARNING: A qualified ser- vice person must install fireplace. Follow all local codes. You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels.
9 107035 OWNER’S MANUAL Continued Figure 11 - Attaching Fireplace to Wall Studs 36 5 / 8 " 25 7 / 8 " 51 3 / 4 " 26 7 / 8 " Figure 10 - Rough Opening for Installing in Corner 1 . Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening.
10 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN 13" 16" 19" 21" 2 1 / 2 " 6" 8" 10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
11 107035 OWNER’S MANUAL 1 2 ASSEMBLING BRASS TRIM (Brass trim shipped with mantel) 1. Remove packaging from three remain- ing pieces of brass trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 15.
12 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN 3 2 1 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of the heater cabinet, locate the four mounting holes on the outer cas- ing. Align these four holes with those on the blower bracket assembly .
13 107035 OWNER’S MANUAL 3 2 1 Figure 21 - Installing Blower Bracket Assembly Blower Bracket Assembly Screw Wire Harness Power Cord Valve Cover Shield Box Cover Wire Harness Switch Plate Switch Clam.
14 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN ATTACHING WOOD BASE TO SOLID FLOOR For attaching base to solid floors (concrete or masonry) Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.
15 107035 OWNER’S MANUAL INST ALLA TION Continued Continued Figure 24 - Removing Log Base Assembly From Fireplace Branch Support Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECT.
16 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system.
17 107035 OWNER’S MANUAL OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1.
18 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN TO TURN OFF GAS TO APPLIANCE Shutting Off Fireplace 1. T urn control knob clockwise to the OFF position. 2. T urn off all electric po wer to the ap- pliance if service is to be perf ormed. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise to the PILOT position.
19 107035 OWNER’S MANUAL TROUBLESHOOTING POSSIBLE CAUSE 1. Ignitor cable pinched or wet 2. Ignitor electrode not connected to igni- tor cable 3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong 1 .
20 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame du.
21 107035 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
22 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN SPECIFICA TIONS Btu (Variable) 14,000/26,000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 3" W.
23 107035 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
24 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 27 39 39 16 15 18 24 28 5 41 34 26 25 20 4 35 12 24 12-1 25 14.
25 107035 OWNER’S MANUAL P AR TS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual.
26 107035 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE CGCFTN ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central (see page 23) . If they cannot supply these accessories call DESA International’s Sales Department at 1- 866-672-6040 for referral information.
27 107035 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 107035-01 Rev. B 02/02 TM LIMITED WARRANTY VENT-FREE NATURAL GAS COMPACT FIREPLACE DESA International warrants this p.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa CGCFTN è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa CGCFTN - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa CGCFTN imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa CGCFTN ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa CGCFTN, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa CGCFTN.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa CGCFTN. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa CGCFTN insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.