Manuale d’uso / di manutenzione del prodotto and FVF30N del fabbricante Desa
Vai alla pagina of 24
UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER ALSO DESIGN- CERTIFIED AS A VENTED DECORA TIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL ® Patent Pending Save this manual for future reference.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 2 105191 1. This appliance is only for use with the type of gas indicated on the rating plate.
OWNER’S MANUAL 3 105191 PRODUCT IDENTIFICA TION PRODUCT FEA TURES OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 4 105191 PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
OWNER’S MANUAL 5 105191 DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 6 105191 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from.
OWNER’S MANUAL 7 105191 WARNING: Never install the heater • in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 10) • in a recreational vehicle • where curtains, furn.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 8 105191 Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using a Mantel. If not using a mantel, follow the information below.
OWNER’S MANUAL 9 105191 INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non- Combustible Material 8" Min.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 10 105191 Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor.
OWNER’S MANUAL 11 105191 INST ALLA TION Continued Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Figure 12 - Attaching Base Assembly to Fireplace Floor Masonry Screw Bracket with Sc.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 12 105191 Tee Joint Pipe Nipple Cap 3" Minimum Sediment Trap Gas Regulator From Gas Meter (5" W.
OWNER’S MANUAL 13 105191 Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff v alve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter . 3 .
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 14 105191 It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in Figure 16.
OWNER’S MANUAL 15 105191 LIGHTING INSTRUCTIONS OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 16 105191 TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and turn contr ol knob clock- wise Clockwise to the HIGH position. 2 . T urn the control knob clockwise Clockwise to the PILOT position.
OWNER’S MANUAL 17 105191 TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 18 105191 OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combus.
OWNER’S MANUAL 19 105191 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 20 105191 CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean.
OWNER’S MANUAL 21 105191 Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED 22 105191 ILLUSTRA TED PA R T S BREAKDOWN HEAT MAJIC™ FVF18N FVF24N FVF30N ODS Pilot 4 12 21 10 11 21 7 21 5 6 8 9 15 14 16 1.
OWNER’S MANUAL 23 105191 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. KEY PART NUMBER FOR NO. FVF18N FVF24N FVF30N DESCRIPTION QTY.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa and FVF30N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa and FVF30N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa and FVF30N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa and FVF30N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa and FVF30N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa and FVF30N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa and FVF30N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa and FVF30N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.