INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .
2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment.
4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times .
8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.
INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air .
10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current.
11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps.
12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence.
13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion.
15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench.
16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator .
17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e.
18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur .
19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit.
20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta OIL-FREE AIR COMPRESSOR CP503 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta OIL-FREE AIR COMPRESSOR CP503 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta OIL-FREE AIR COMPRESSOR CP503 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta OIL-FREE AIR COMPRESSOR CP503 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta OIL-FREE AIR COMPRESSOR CP503, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta OIL-FREE AIR COMPRESSOR CP503.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta OIL-FREE AIR COMPRESSOR CP503. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta OIL-FREE AIR COMPRESSOR CP503 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.