Manuale d’uso / di manutenzione del prodotto Series S48SA del fabbricante Delta Electronics
Vai alla pagina of 13
DA T ASHEET DS_S48SA1R812_06 012006 Delta Electronics, Inc. Delphi Series S48SA, 33W Family DC/DC Power Modules: 48V in, 1.8V/12A out The Delphi Series S48SA, surface mountable, 48V input, single output, isolated DC/DC converter is the latest offeri ng from a world leader in power system and technology and manu facturing – Delta Electronics, Inc.
DS_S48SA1R812_06012 006 TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vou t unless otherwise noted.) PARAMETER NOTES and CONDITIONS S48SA1R812NRFA Min.
DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES 55 60 65 70 75 80 85 90 95 12 345 67 89 1 0 1 1 1 2 O U TPU T C U R R E N T (A ) E FFICIE NCY ( % ) 36Vin 48Vin 75Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 123456 789 1 0 1 1 1 2 O UT PUT CU RRE NT (A ) P O WE R DIS S IP A TIO N ( W) 36Vin 48Vin 75Vin Figure 1: Efficiency vs.
DS_S48SA1R812_06012 006 4 ELECTRICAL CHARACTERISTICS CURVES Figure5 : Turn-on transie nt at zero load current (1 ms/div). Top Trace: Vout (500mV/div); Bottom Trace: ON/OFF Control (5V/div). Figure 6: Output voltage response to step-change in load current (50%-75% of Io, max; di/dt = 0.
DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 9 : Input Reflected Ripple Current, i s , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 33 µ F electrolytic capacito r (2 mA/div).
DS_S48SA1R812_06012 006 This power module is not internally fused. To a chieve optimum safety and system protection, an input line fuse is highly recommended. T he safety agencies require a normal-blow fuse with 3A maximum rating to be installed in the ungrounded le ad.
DS_S48SA1R812_06012 006 Vo(+) Vi(+) Vo(-) Sense(-) Sense(+) Vi(-) ON/OFF Figure 13: Remote on/off implementation Remote Sense (Optional) Remote sense compensates for voltage drop s on the output by sensing the actual output voltage at the p oint of load.
DS_S48SA1R812_06012 006 [] ΚΩ − ∆ = − 104 % Vo up − ∆ + 1089 %) 100 ( 8 . 23 Vo Ex. When trim-up +10% (1.8V X 1.1 = 1.98V) Rtrim [] ΚΩ = − = − 9 .
DS_S48SA1R812_06012 006 9 THERMAL CONSIDERATIONS Thermal management is an im porta nt part of the system design. To ensure proper, reliable operation, sufficie nt cooling of the power module is neede d over the entire temperature range of the modul e.
DS_S48SA1R812_06012 006 10 PICK AND PLACE LOCATION SURFAC E-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD).
DS_S48SA1R812_06012 006 Temp . Time 150 ℃ 200 ℃ 100~140 sec. T ime Limited 9 0 sec. above 217 ℃ 217 ℃ Preheat time Ramp up max. 3 ℃ /sec. Ramp down max. 4 ℃ /s ec. Peak Tem p . 240 ~ 245 ℃ 25 ℃ Note: The temperature refers to the pin of S48SA, measured on the pin +Vout joint.
DS_S48SA1R812_06012 006 MECHANICAL DRAWING SMD Through-Hole Pin No. Name Function 1 +Vout Positive output voltage 2 -Vout Negative output voltage 6 Trim Output voltage trim 8 ON/OFF ON/OFF logic 11 -V.
DS_S48SA1R812_06012 006 14 PART NUMBERING SYSTEM S 48 S A 1R8 12 N R F A* Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Type Option Code S- Small Power 48V S- Single A- Advanced 1R2-1.2V 1R5-1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Series S48SA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Series S48SA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Series S48SA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Series S48SA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Series S48SA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Series S48SA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Series S48SA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Series S48SA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.