FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30”x0.90”x0.36”) Industry standard pin out 18~75V extremely wide 4:1 input r ange Fixed frequency ope.
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E36SR05015 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C. DS_E36SR05015_010 42008 3 Figure 2: Power dissipation vs. load current for min imum, nominal, and max i mum input voltage at 25°C.
ELECTRICAL CHARACTERISTICS CUR VES Figure 4: T urn-on trans ient at full rated load current (CC mode) (5ms/div). Vin=48V .T op T rac e: V out, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 5: T urn-on transient at zero load current (5ms/ div). Vin=48V .
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum cap acitor and 1 µF ceramic cap acitor. T op T race: Vout (100mV/div , 200us/div), Bottom T race: I out (5A/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at 48Vin and 15A output current (20 mA/ div , 2us/div). Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 13: Output voltage noise and ripple measur ement test setup.
The input source must be insulated f rom the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E36SR05015_010 42008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E36SR05015_010 42008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD) DS_E36SR05015_010 42008 11.
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input.
MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE DS_E36SR05015_010 42008 14.
DS_E36SR05015_010 42008 15 P ART NUMBERING SYSTEM E 36 S R 050 15 N R F A T ype of Product Input V o ltage Number of Output s Product Series Output V o ltage Output Current ON/OFF Logic Pin Length/T ype Option Code E- Eighth Brick 36-18~75V S- Single R- Regular 050- 5.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Series E36SR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Series E36SR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Series E36SR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Series E36SR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Series E36SR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Series E36SR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Series E36SR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Series E36SR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.