(2.30” x 0.90” x 0.39”) SMD and Through-hole versions Industry standard pin out 2:1 input range Fixed frequency operation Input UVLO, Output OTP , OCP , OVP Basic insulat.
DS_E24SR05012_010 32008 2 TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in = 24 Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E24SR05012 (St andard) Min.
DS_E24SR05012_010 32008 3 ELECTRICAL CHARACTERISTICS CUR VES 80 82 84 86 88 90 92 24 68 1 0 1 2 Output C ur r ent ( A ) E ff i ci en cy (%) 1. 0 2. 0 3. 0 4. 0 5. 0 6. 0 7. 0 2468 1 0 O utput C ur r ent ( A ) L o ss (W ) 18Vin 1 2 Figure 1: Ef ficiency vs.
DS_E24SR05012_010 32008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transi ent at full rated load current (resi stive load) (2 ms/div). Vin=24V . T op T race: V out, 2.0V/div; Bottom T race: ON/OFF input, 10V/div Figure 5: T urn-on trans ient at zero load current (2 ms/ div).
DS_E24SR05012_010 32008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF t antalum capacitor and 1µF ceramic capacitor . 0 T op T race: Vout (100mV/div , 200us/div ) , Bottom T r ace: Iout (5 A /div).
DS_E24SR05012_010 32008 6 ELECTRICAL CHARACTERISTICS CUR VES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at nominal input voltage and rated loa d current (20 mA/div , 2us/div) Figure 13: Output voltage noise and ripple measur ement test setup 0.
DS_E24SR05012_010 32008 7 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E24SR05012_010 32008 8 Vi(-) ON/OFF Vi(+) Vo(-) Trim Vo(+) Sense(-) Sense(-) Vi(-) ON/OFF Vi(+) Vo(-) Trim Vo(+) Sense(-) Sense(-) Figure 16: Remote on/off implementation Remote Sense Remote sense compen sates for voltage dro ps on the output by sensing the actual output volt age at the point of load.
DS_E24SR05012_010 32008 9 FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, connect an external re sistor between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E24SR05012_010 32008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_E24SR05012_010 32008 11 P I C K A N D P L A C E L O C A T I O N S U R F A C E - MOUNT T APE & REEL RECOMMENDED P AD LA YOUT (SMD).
DS_E24SR05012_010 32008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
DS_E24SR05012_010 32008 13 MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 -Vin Negative input voltage Remote ON/OFF Positive input voltage Positive output voltage.
DS_E24SR05012_010 32008 14 P ART NUMBERING SYSTEM E 24 S R 050 12 N R F A T ype of Product Input V oltage Number of Output s Product Series Output V oltage Output Current ON/OFF Logic Pin Length/T ype Option Code E - Eighth Brick 24V S - Single R - Regular 050 - 5.
DS_E24SR05012_010 32008 15 at any time, without notice ..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Series E24SR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Series E24SR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Series E24SR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Series E24SR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Series E24SR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Series E24SR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Series E24SR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Series E24SR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.