DATASHEET DS_DNM04SIP10_ 07162008D FEATURES High efficiency: 96% @ 5.0Vin, 3.3V/10A out Small size and low profile: (SIP) 50.8x 13.4x 8.5 mm (2.
DS_DNM04SIP10_071620 08D 2 TECHNICAL SPECIFICA TIONS (T A = 25°C, airfl ow rate = 300 LFM, V in = 2.8Vdc and 5.5V dc, nominal V out u nless otherwise noted.) P ARAMETE R NOTES and CONDITIONS DNM04S0A0R10 Min. T yp. Max. Units ABSOLUTE MAXIMUM RA TINGS Input V oltage (Continuous) 0 5.
DS_DNM04SIP10_071620 08D 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Converter efficiency vs. output current (3.3V out) Figure 2: Converter efficiency vs. output current (2.5V out) Figure 3: Converter efficiency vs. output current (1.8V out) Figure 4 : Converter efficiency vs.
DS_DNM04SIP10_071620 08D 4 ELECTRICAL CHARACTERISTICS CUR VES Figure 7: Output ripple & noise at 3.3V in, 2.5V/10A out Figure 8: Outp ut ripple & noise at 3.3Vin, 1.8V/10A out Figure 9: Output ripple & noise at 5Vin, 3.3V/10A out Figure 10: Output ripple & noise at 5Vin, 1.
DS_DNM04SIP10_071620 08D 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 13: T urn on delay time at 5Vin, 3.3V/10A out Figure 14: T urn on delay ti me at 5Vin, 1.8V/10A out Figure 15: T urn on delay time at remote turn on 5Vin, 3.3V/16A out Figure 16: T urn on delay time at remote turn on 3.
DS_DNM04SIP10_071620 08D 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 19: T ypical transient response to step load change at 2.5A/ μ S from 100% to 50% of Io, max at 5Vin, 3.3V out (Cout = 1uF ceramic, 10 μ F tantalum) Figure 20: T ypical transient response to step load change at 2.
DS_DNM04SIP10_071620 08D 7 ELECTRICAL CHARACTERISTICS CUR VES Figure 23: T ypical transient response to step load change at 2.5A/ μ S from 100% to 50% of Io, max at 3.3Vin, 2.5V o ut (Cout =1uF ceramic, 10 μ F t antalum) Figure 24: T ypical transient response to step load change at 2.
DS_DNM04SIP10_071620 08D 8 TEST CONFIGURA TIONS V I (+) V I (-) BATTERY 2 100uF Tantalum L TO OSCILLOSCOPE Note: Input reflected-ripple current is measured with a simulated sour ce inductance.
DS_DNM04SIP10_071620 08D 9 DESIGN CONSIDERA TIONS (CON.) The power module sh ould be conne cted to a low ac-impedance input source. Hig hly inductive source impedances can af fect the st ability of the module.
DS_DNM04SIP10_071620 08D 10 FEA TURES DESCRIPTIONS (CON.) Over-T emperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the ove r-temperature thre shold the module will shut down.
DS_DNM04SIP10_071620 08D 11 The output voltage tracking f eature (Figure 40 to Figure 42) is achieved according to the different extern al connections. If the tracking feature is not used, the TRACK pin of the module can be le ft unconnecte d or tied to Vin.
DS_DNM04SIP10_071620 08D 12 FEA TURE DESCRIPTIONS (CON.) Sequential St art-up Sequential start-u p (Figure 40) is implemented by placing an On/Off control circuit b etween V o PS1 and the On/Of f pin of PS2.
DS_DNM04SIP10_071620 08D 13 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_DNM04SIP10_071620 08D 14 THERMAL CURVES Figure 44: T emperature mea surement location * The allowed max imum hot spot temperature is defined at 125 ℃ DNM04S0A0R10( Standard) Output Current vs. Ambient Tem perature and Air Velocity @ Vin = 5V, Vo = 3.
DS_DNM04SIP10_071620 08D 15 MECHANICAL DRA WING SMD P ACKAGE (OPTIONAL) SIP P ACKAGE.
DS_DNM04SIP10_071620 08D 16 P ART NUMBERING SYSTEM DNM 04 S 0A0 R 10 P F D Product Series Input V olt ag e Numbers of Output s Output V olt age Package Ty p e Output Current On/Off logic Option Code DNL - 16A DNM - 10A DNS - 6A 04 - 2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Series DNM04 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Series DNM04 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Series DNM04 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Series DNM04 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Series DNM04, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Series DNM04.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Series DNM04. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Series DNM04 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.