FEA TURES High efficiency: 90% @5V/7A Industry standard 1x2 pin out Size: 33.0x24.4x8.55mm (1.30”x0.96”x0.34”) SMD and Through-hole versions Fixed frequency operation 2:1.
DS_S48SP05007_05222008 2 TECHNICAL SPECIFICA TIONS ( T A =25°C, airflow rate=300 LFM, V in =48Vdc, n ominal V out unle ss otherwise noted.) PA R A M E T E R NOTES and CONDITIONS S48SP05007 (St andard) Min.
DS_S48SP05007_05222008 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Ef ficiency vs. load current for minimum, nomi nal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs. load current for min imum, nominal, and max imum input voltage at 25°C.
DS_S48SP05007_05222008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full rated load current (5 ms/div). Vin=48V . T op T race: V out, 2V/div; Bottom T race: ON/OFF input, 2V/div Figure 5: T urn-on transient at zero load current (5 ms/ div).
DS_S48SP05007_05222008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF tantalum cap acitor and 1 µF ceramic capa citor. T op T race: V out (100mV/div , 50us/div), Bottom T race: Iout (2A/div).
DS_S48SP05007_05222008 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 1 1: Input T erminal Ripple Current, i c , at full rated out put current and nominal i nput voltage with 12µH source impedance and 3.
DS_S48SP05007_05222008 7 DESIGN CONSIDERA TIONS Input Source Impedance The impedance of the input sou rce connecting to the DC/DC powe r modules will interact wit h the modules and affect the stability. A low ac-impedance input sou rce is recommended.
DS_S48SP05007_05222008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload.
DS_S48SP05007_05222008 9 FEA TURES DESCRIPTIONS (CON.) Output V olt age Adjustment To increase or decrea se the output voltage set point, the modules may be connected wit h an external resistor between the TRIM pin and either the Vo (+) or Vo(-). The TRIM pin should be left open if this feature is not used.
DS_S48SP05007_05222008 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, sufficient cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_S48SP05007_05222008 11 P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD).
DS_S48SP05007_05222008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
DS_S48SP05007_05222008 13 MECHANICAL DRA WING Surface-mount module Through-Hole module Pin No. Name Function 1 2 3 4 5 6 +Vin -Vin ON/OFF (Optional) -V out TRIM (Optional) +V out Positive input voltag.
DS_S48SP05007_05222008 14 P ART NUMBERING SYSTEM S 48 S P 050 07 N R F B Product Ty p e Input V oltage Number of Output s Product Series Output V oltage Output Current ON/OFF Logic Pin Length/T ype Op.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics S48SP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics S48SP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics S48SP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics S48SP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics S48SP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics S48SP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics S48SP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics S48SP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.