DATASHEET DS _ S24S A 1R812 _ 05092006 Delta Electronics, Inc. Delphi Series S24SA, 2”x1” Family DC/DC Power Modules: 18~36Vin, 1.8V, 12A out The Delphi Series S24SA, surface mou ntable, 24V input.
DS_S24SA1R812_05092 006 TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=200 LFM, V in =24Vdc, nominal V out unless otherw ise noted.) PARAMETER NOTES and CONDITIONS S24SA1R812NRFA Min. Ty p. Max. Units Units ABSOLUTE MAXIMUM RA TINGS Input Voltage Continuous -0.
DS_S24SA1R812_05092 006 ELECTRICAL CHARACTERISTICS CURVES 50 55 60 65 70 75 80 85 90 95 0. 1 2 4 6 8 10 12 O UTP UT CURRE NT (A ) EFFICIENCY (%) 18Vi n 24V in 36V i n 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 0.1 2 4 6 8 10 12 O UT PUT CURRE NT (A ) POWER DISSIPATION (W) 18Vi n 24V i n 36V i n Figure 1: Efficiency vs.
DS_S24SA1R812_05092 006 4 ELECTRICAL CHARACT ERISTICS CURVES Figure5 : Turn-on transie nt at zero load current (2 ms/div). Top Trace: Vout (1mV/div); Bottom Trace: ON/OFF Control (5V/div). Figure 6: Output voltage response to step-change in l oad current (50%-75% of Io, max; di/dt = 0.
DS_S24SA1R812_05092 006 ELECTRICAL CHARACTERISTICS CURVES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 9 : Input Reflected Ripple Current, i s , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 100 µ F electrolytic capacitor (2 mA/div).
DS_S24SA1R812_05092 006 This power module is not internally fused. To a chieve optimum safety and system protection, an input line fuse is highly recommended. T he safety agencies require a normal-blow fuse with 5A maximum rating to be installed in the ungrounded le ad.
DS_S24SA1R812_05092 006 7 Vo(+) Vi(+) Vo(-) Sense(-) Sense(+) Vi(-) ON/OFF Figure 13: Remote on/off implementation Remote Sense (Optional) Remote sense compensates for voltage drop s on the output by sensing the actual output voltage at the p oint of load.
DS_S24SA1R812_05092 006 [] ΚΩ − ∆ = − 104 % Vo up Rtrim − ∆ + 1089 %) 100 ( 8 . 23 Vo Ex. When trim-up +10% (1.8V X 1.1 = 1.98V) [ ] ΚΩ = − = − 9 .
DS_S24SA1R812_05092 006 9 THERMAL CONSIDERATIONS Thermal management is an im porta nt part of the system design. To ensure proper, reliable operation, sufficie nt cooling of the power module is neede d over the entire temperature range of the modul e.
DS_S24SA1R812_05092 006 10 PICK AND PLACE LOCATION SURFAC E-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD).
DS_S24SA1R812_05092 006 Temp . Time 150 ℃ 200 ℃ 100~140 sec. Time Limited 9 0 sec. above 217 ℃ 217 ℃ Preheat time Ramp up max. 3 ℃ /sec. Ramp down max. 4 ℃ /s ec. Peak Tem p . 240 ~ 245 ℃ 25 ℃ Note: The temperature refers to the pin of S24SA, measured on the pin +Vout joint.
DS_S24SA1R812_05092 006 Pin No. Name Function 1 +Vout Positive output voltage 2 -Vout Negative output voltage 6 Trim Output voltage trim 8 ON/OFF ON/OFF logic 11 -Vin Negative input voltage 12 +Vin Po.
DS_S24SA1R812_05092 006 14 PART NUMBERING SYSTEM S 24 S A 1R8 12 N R F A Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Type Option Code S- Small Power 24V S- Single A- Advanced 1R2-1.2V 1R5-1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics S24SA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics S24SA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics S24SA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics S24SA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics S24SA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics S24SA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics S24SA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics S24SA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.