Delphi Series H48SV , 150W Half Brick Family DC/DC Power Modules: 48V in, 5V/20A out The Delphi Series H48SV Half Brick, 48V input, single output, isol ated DC/DC converters a re the latest of fering from a world leader in power systems technology and manufacturi ng — Delt a Electronics, Inc.
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V ou t unless otherw ise no ted.) PA R A M E T E R NOTES and CONDITIONS H48SV05020 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES 60 65 70 75 80 85 90 95 2.5 5 7.5 10 12.5 15 17.5 20 OUT PUT CURRE NT (A) EFFICIENCY (%) 36Vin 48Vi n 75Vin 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 2.5 5 7.5 10 12.5 15 17.5 20 OUTPUT CURRENT(A) POWER DISS IPATION (W) 36Vin 48Vin 75Vin Figure 1: Efficiency vs.
ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full rated l oad current (resistive load) (2 ms/div).Vin=48V . T op T race: V out; 2V/div; Bottom T race: ON/OFF input: 5V/div Figure 5: T urn-on transient at zero load current (2 ms/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-75%-50% of Imax; dI/dt = 0.1A/µs).Vin=48V . Load cap: 10µF , tantalum capacitor and 1µF ceramic capacitor . T op trace: V out (100 mV/div), Botto m trace: Iout (5A/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 1 1 : Input T erminal Ri pple Current, i c , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 33 µ F electrolytic capacitor (200 mA/div).
ELECTRICAL CHARACTERISTICS CUR VES 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 5 10 15 20 25 30 LO A D CURRENT (A) OUTPUT VOLTAGE (V) Vi n=48V Figure 14: Output volt age ripple at nominal input voltage (Vin=48V) and rated loa d current (Io=2 0A) (20 mV/di v).
THERMAL CURVES: NO HEA TSINK Figure 16: Case temperature measurement location. Pin locations are for referenc e only . Figure 17: Output current vs. ambient temperature and air velocity (V in <60V) Figure 18: Output current vs. ambient temperature and air velocity (V in =75V) Figure 19: Power dissipation vs.
9 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
11 Figure 23: Circuit configuration for trim-up (increase output voltage) If the external resistor is connected bet ween the TRIM and SENSE (+) the output voltage set point increase s (Fig.
THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer.
MECHANICAL DRA WING Pin No. Name Function 1 2 3 4 5 6 7 8 9 -Vin Case ON/OFF +Vin +V out +SENSE TRIM -SENSE -V out Negative input voltage Case Ground Remote ON/OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage Pin Specification: Pins 1-4, 6-8 1.
P ART NUMBERING SYSTEM H 48 S V 050 20 N R F A Form Factor Input V oltage Number of Output s Product Series Output Vo l t a g e Output Current ON/OFF Logic Pin Length Option Code H - Half Brick 48V S- Single V - V alue line 050- 5V 20- 20A N- Negative P- Positive R- 0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Delphi Series H48SV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Delphi Series H48SV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Delphi Series H48SV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Delphi Series H48SV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Delphi Series H48SV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Delphi Series H48SV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Delphi Series H48SV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Delphi Series H48SV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.