DATASHEET DS_DNS04SIP06_07 172008D FEATURES High efficiency: 94% @ 5.0V in, 3.3V/6A out Small size and low profile: (SIP) 25.4 x 12.7 x 6.7mm (1.
DS_DNS04SIP06A_07172008 2 TECHNICAL SPECIFICA TIONS (T A = 25°C, airfl ow rate = 300 LFM, V in = 2.8Vdc and 5.5Vdc, nominal V out u nless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS DNS04S0A0R06PFD Min. T yp. Max. Units ABSOLUTE MAXIMUM RA TINGS Input V oltage (Continuous) 0 5.
DS_DNS04SIP06A_07172008 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Converter efficiency vs. output current (3.3V out) Figure 2: Converter efficiency vs. output current (2.5V out) Figure 3: Converter efficiency vs. output current (1.8V out) Figure 4 : Converter efficiency vs.
DS_DNS04SIP06A_07172008 4 ELECTRICAL CHARACTERISTICS CUR VES (CON.) Figure 7: Output ripple & noise at 3.3Vin, 2.5V/6A out Figure 8: Output ripple & noise at 3.3V in, 1.8V/6A out Figure 9: Output ripple & noise at 5Vin, 3.3V/6A out Figure 10: Output ripple & noise at 5Vin, 1.
DS_DNS04SIP06A_07172008 5 ELECTRICAL CHARACTERISTICS CUR VES (CON.) Figure 13: T urn on delay ti me at 5Vin, 3.3V/6A out Figure 14: T urn on delay time at 5Vin, 1.8V/6A out Figure 15: T urn on delay time at remote turn on 5Vin, 3.3V/16A out Figure 16: T urn on delay time at remote tur n on 3.
DS_DNS04SIP06A_07172008 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 19: T ypical transient respons e to step load change at 2.5A/ μ S from 100% to 50% of Io, max at 5Vin, 3.3V out (Cout = 1uF ceramic, 10 μ F tantalum) Figure 20: T ypical transient respons e to step load change at 2.
DS_DNS04SIP06A_07172008 7 ELECTRICAL CHARACTERISTICS CUR VES (CON.) Figure 23: T ypical transient respons e to step load change at 2.5A/ μ S from 100% to 50% of Io, max at 3.3Vin, 2.5V o ut (Cout =1uF ceramic, 10 μ F t antalum) Figure 24: T ypical transient response to step load change at 2.
DS_DNS04SIP06A_07172008 8 TEST CONFIGURA TIONS V I (+) V I (-) BATTERY 2 100uF Tantalum L TO OSCILLOSCOPE Note: Input reflected-ripple current is measured with a simulated sour ce inductance.
DS_DNS04SIP06A_07172008 9 DESIGN CONSIDERA TIONS (CON.) The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can af fect the stab ility of the module.
DS_DNS04SIP06A_07172008 10 FEA TURES DESCRIPTIONS (CON.) Over-T emperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the ove r-temperature thre shold the module will shut down.
DS_DNS04SIP06A_07172008 11 The output voltage tracking f eature (Figure 40 to Figure 42) is achieved according to the different extern al connections. If the tracking feature is not used, the TRACK pin of the module can be le ft unconnecte d or tied to Vin.
DS_DNS04SIP06A_07172008 12 FEA TURE DESCRIPTIONS (CON.) Sequential St art-up Sequential start-u p (Figure 40) is implemented by placing an On/Off control circuit b etween V o PS1 and the On/Off pin of PS2.
DS_DNS04SIP06A_07172008 13 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_DNS04SIP06A_07172008 14 DNS04S0A0R06(Standard) Output Current vs. Ambient Temperat ure and Air Velocity @ Vin = 5.0V, Vo = 0.75V (Ei ther Orientation) 0 1 2 3 4 5 6 7 60 65 70 75 80 85 Ambient Temperature ( ℃ ) Output Current(A) Natural Convection Figure 47: DNS04S0A0R06 (St andar d) Output current vs.
DS_DNS04SIP06A_07172008 15 MECHANICAL DRA WING SMD P ACKAGE (OPTIONAL) SIP P ACKAGE.
DS_DNS04SIP06A_07172008 16 P ART NUMBERING SYSTEM DNS 04 S 0A0 R 06 P F D Product Series Input V oltage Numbers o f Output s Output V olt age Package Ty p e Output Current On/Off logic Option Code DNS - 6A DNM - 10A DNL - 16A 04 - 2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Delphi Series DNS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Delphi Series DNS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Delphi Series DNS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Delphi Series DNS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Delphi Series DNS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Delphi Series DNS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Delphi Series DNS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Delphi Series DNS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.