Dell PowerEdge R420xr Owner's Manual Regulatory Model: E27S Series Regulatory Type: E27S001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents 1 About Your System ................................................................................................... 8 Front-Panel Features And Indicators ....................................................................................
Entering The iDRAC Settings Utility .............................................................................................. 30 Changing The Thermal Settings .......................................................................................
Installing The iDRAC Enterprise Card ........................................................................................... 61 SD vFlash Card ........................................................................................................
Troubleshooting External Connections ............................................................................................. 89 Troubleshooting The Video Subsystem .................................................................................
Contacting Dell ................................................................................................................................. 128 Locating Your System Service Tag ....................................................................
1 About Your System Front-Panel Features And Indicators Figure 1. Front-Panel Features and Indicators Item Indicator, Button, or Connector Icon Description 1 Power-on indicator, power button The power-on indicator lights when the system power is on. The power button controls the power supply output to the system.
Item Indicator, Button, or Connector Icon Description 4 LCD menu buttons Allow you to navigate the control panel LCD menu. 5 LCD panel Displays system ID, status information, and system error messages. The LCD lights blue during normal system operation.
Figure 2. LCD Panel Features Item Button Description 1 Left Moves the cursor back in one- step increments. 2 Select Selects the menu item highlighted by the cursor.
Drive-Status Indicator Pattern (RAID Only) Condition Blinks green two times per second Identifying drive or preparing for removal Off Drive ready for insertion or removal NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on.
Item Indicator, Button, or Connector Icon Description 6 Video connector Allows you to connect a VGA display to the system. 7 Ethernet connectors (2) Integrated 10/100/1000 Mbps NIC connector. 8 USB connectors (2) Allow you to connect USB devices to the system.
Indicator Indicator Code Link indicator is amber The NIC is connected to a valid network at less than its maximum port speed. Activity indicator is blinking green Network data is being sent or received.
Power Indicator Pattern Condition status, and supported voltage). Replace the power supply that has the flashing indicator with a power supply that matches the capacity of the other installed power supply. Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system.
2 Using The System Setup and Boot Manager System Setup enables you to manage your system hardware and specify BIOS-level options. The following keystrokes provide access to system features during startup: Keystroke Description <F2> Opens the System Setup page.
Choosing The System Boot Mode System Setup enables you to specify the boot mode for installing your operating system: • BIOS boot mode (the default) is the standard BIOS-level boot interface. • UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BIOS.
NOTE: For the standard graphics browser only. <Esc> Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen displays a message that prompts you to save any unsaved changes and restarts the system. <F1> Displays the System Setup help file.
Menu Item Description System Security Displays options to configure the system security settings like, system password, setup password, TPM security, and so on. It also enables or disables the power and NMI buttons on the system. Miscellaneous Settings Displays options to change the system date, time, and so on.
Menu Item Description NOTE: The Memory Operating Mode can have different defaults and available options based on the memory configuration. NOTE: The Dell Fault Resilient Mode establishes an area of memory that is fault resilient.
Menu Item Description Logical Processor Idling Allows you to enable or disable the OS capability to put logical processors in the idling state in order to reduce power consumption. By default, the option is set to Disabled . Number of Cores per Processor Allows you to control the number of enabled cores in each processor.
NOTE: Ports A, B, C, and D are used for the backplane drives, and port E for the optical drive (CD/ DVD). Boot Settings Screen Menu Item Description Boot Mode Allows you to set the boot mode of the system. CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in the same boot mode.
Menu Item Description Internal SD Card Redundancy If set to Mirror mode, data is written on both SD cards. If any one of the SD card fails, data is written to the active SD card. Data from this card is copied to the replacement SD card at the next boot.
Menu Item Description NOTE: Only Serial Device 2 can be used for SOL. To use console redirection by SOL, configure the same port address for console redirection and the serial device. Failsafe Baud Rate Displays the failsafe baud rate for console redirection.
Menu Item Description Memory Patrol Scrub Allows you to set the memory patrol scrub frequency. By default, the Memory Patrol Scrub option is set to Standard . Memory Refresh Rate Allows you to set the memory refresh rate. By default, the Memory Refresh Rate option is set to 1x .
Menu Item Description this option to Disabled . By default, the BIOS Update Control option is set to Unlocked . NOTE: BIOS updates using the Dell Update Package are not affected by this option. Power Button Allows you to enable or disable the power button on the front of the system.
System password This is the password that you must enter before you can boot your system. Setup password This is the password that you must enter to access and make changes to the BIOS or UEFI settings of your system. CAUTION: The password features provide a basic level of security for the data on your system.
Deleting Or Changing An Existing Setup Password Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or change the existing System and/or Setup password. You cannot delete or change an existing System password if the Password Status is Locked .
If you do not enter the correct password in three attempts, the system displays the message Invalid Password! Number of unsuccessful password attempts: <x> System Halted! Must power down. Even after you shut down and restart the system, the error message is displayed until the correct password is entered.
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system. Boot Manager Screen Menu Item Description Continue Normal Boot The system attempts to boot to devices starting with the first item in the boot order.
iDRAC Settings Utility The iDRAC Settings utility is an interface to set up and configure the iDRAC parameters using UEFI. You can enable or disable various iDRAC parameters using the iDRAC Settings Utility. NOTE: Accessing some of the features on the iDRAC Settings Utility requires the iDRAC7 Enterprise License upgrade.
3 Installing System Components Recommended Tools You may need the following items to perform the procedures in this section: • #2 Phillips screwdriver • T10 and T15 Torx screwdrivers • Wrist gro.
Installing The Front Bezel 1. Align the thumb screws on the bezel with the rack ears on the front of the system. 2. Tighten the thumb screws to secure the bezel to the system chassis. Figure 7. Installing and Removing the Front Bezel 1. front bezel 2.
3. Remove the filter. Figure 8. Removing and Installing the Bezel Filter 1. bezel 2. screw 3. filter 4. filter frame NOTE: It is recommended that you clean or replace the filter once every three months. To purchase additional replacement filters, contact Dell Technical Support.
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. CAUTION: Many repairs may only be done by a certified service technician.
5. Grasp the cover on both sides and lift the cover away from the system. Figure 9. Opening and Closing the System 1. system cover 2. Mylar adhesive sheaths (5) 3.
Inside The System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
13. cable routing latch 14. power distribution board 15. power distribution board shroud Cooling Shroud Removing The Cooling Shroud CAUTION: Many repairs may only be done by a certified service technician.
3. Lift the shroud away from the fan bracket. Figure 11. Removing and Installing the Cooling Shroud 1. cooling shroud 2. cooling shroud tabs (4) 3. cooling-fan bracket Installing The Cooling Shroud CAUTION: Many repairs may only be done by a certified service technician.
System Memory Your system supports DDR3 unbuffered ECC DIMMs (UDIMM ECC) and registered DIMMs (RDIMMs). It supports DDR3 and DDR3L voltage specifications.
Figure 12. Memory Socket Locations Memory channels are organized as follows: Processor 1 channel 1: memory sockets A1 and A4 channel 2: memory sockets A2 and A5 channel 3: memory sockets A3 and A6 Pro.
General Memory Module Installation Guidelines This system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for best performance: • UDIMMs and RDIMMs must not be mixed.
NOTE: Advanced ECC with mirroring is not supported. Memory Optimized (Independent Channel) Mode This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot population requirements. Memory Sparing NOTE: To use memory sparing, this feature must be enabled in the System Setup.
Table 1. Memory Configurations — Single Processor System Capacity (in GB) DIMM Size (in GB) Number of DIMMs Organization and Speed DIMM Slot Population 2 2 1 1R x8, 1333 MT/s 1R x8, 1600 MT/s A1 4 2.
System Capacity (in GB) DIMM Size (in GB) Number of DIMMs Organization and Speed DIMM Slot Population 1R x8, 1600 MT/s 12 2 6 1R x8, 1333 MT/s 1R x8, 1600 MT/s A1, A2, A3, B1, B2, B3 24 4 6 2R x8, 133.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets. 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and peripherals.
6. If a memory module or a memory-module blank is installed in the socket, remove it. NOTE: Retain removed memory-module blank(s) for future use. Figure 14. Removing The Memory Module 1. memory module/memory-module blank 7. Install the cooling shroud.
5. If a memory module or a memory-module blank is installed in the socket, remove it. NOTE: Retain removed memory-module blank(s) for future use. 6. Align the memory-module's edge connector with the alignment key of the memory-module socket, and insert the memory module in the socket.
Hard Drives Depending on the configuration, your system supports up to four 2.5 inch, hot-swappable SAS or SATA SSDs. NOTE: SSD/SAS/SATA hard drives cannot be mixed in a system. The hot-swappable hard drives connect to the system board through the hard-drive backplane.
Figure 16. Removing and Installing a Hot-Swap Hard Drive 1. hard drive carrier 2. thumb screws (2) 3. screw holes (2) Installing A Hot-Swap Hard Drive CAUTION: Many repairs may only be done by a certified service technician.
3. Tighten the thumb screws to lock the hard drive in place. Removing A Hard Drive From A Hard-Drive Carrier 1. Remove the screws from the slide rails on the hard-drive carrier. 2. Slide the hard drive out of the hard-drive carrier. Figure 17. Removing and Installing a Hot-Swap Hard Drive Into a Hard-Drive Carrier 1.
1. Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the back. 2. Align the screw holes on the hard drive with the back set of holes on the hard-drive carrier. When aligned correctly, the back of the hard drive will be flush with the back of the hard-drive carrier.
Removing A Cooling Fan WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise utmost care while removing or installing cooling fans. CAUTION: Many repairs may only be done by a certified service technician.
Installing A Cooling Fan CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
8. Enter the System Setup and verify that the USB key is detected by the system. Figure 20. Replacing the Internal USB Key 1. USB memory key 2. USB memory key connector Expansion Cards And Expansion-Card Risers NOTE: A missing or an unsupported expansion-card riser logs an SEL event.
Table 4. Expansion-Card Installation Priority Card Priority Card Type Height Slot Priority Max Allowed Per Slot 1 RAID Full Height Low Profile 2 1 2 Converged Network Adapters (CNAs) Full Height Low P.
7. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch. NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the system.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Figure 21. Removing and Installing the Expansion Card from Expansion-Card Riser 1 1. expansion card 2. expansion-card latch 3. riser touch points (2) 4.
3. expansion-card latch 4. expansion card 5. expansion-card holder 6. tab Installing An Expansion Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
4. Holding the touch points, lift the expansion-card riser from the riser connector on the system board. Figure 23. Removing and Installing the Expansion-Card Riser 1 1. expansion-card riser 1 2. expansion-card riser touch points (2) 3. riser guides (2) 4.
5. riser guides (2) 5. Replace the expansion-card riser. 6. Close the system. 7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Installing Expansion-Card Risers 1 And 2 CAUTION: Many repairs may only be done by a certified service technician.
7. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch. NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the system.
7. Align the iDRAC Enterprise card bracket with the hooks on the chassis. 8. Insert the card-edge connector firmly into the iDRAC Enterprise card connector until the card is fully seated. 9. Slide the expansion-card latch into position. 10. If applicable, connect cables to the iDRAC Enterprise card.
Removing The Internal Dual SD Module CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Figure 27. Removing and Installing the Internal Dual SD Module 1.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Internal SD Card Removing An Internal SD Card CAUTION: Many repairs may only be done by a certified service technician.
Removing The Integrated Storage Controller Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Figure 28. Removing and Installing the Integrated Storage Controller Card 1. touch-points (2) 2. storage controller card 3. storage-controller card holder 4.
3. Align one end of the card with the storage-controller card holder on the system board. 4. Lower the other end of the card into the storage-controller card connector on the system board. 5. Press the touch-points on the card and push the card down until it is fully seated.
8. Lift the heat sink up from the processor and set the heat sink aside upside-down (thermal grease side facing up). Figure 29. Removing and Installing the Processor Heat Sink 1. retention sockets (4) 2. heat sink 3. retention screws (4) CAUTION: The processor is held in its socket under strong pressure.
11. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor. Figure 30. Removing and Installing a Processor 1. processor 2. processor shield 3. notches in processor (2) NOTE: After removing the processor, place it in an antistatic container for reuse, return, or temporary storage.
NOTE: If you install a second processor, you must remove the dummy fan from the FAN 6 slot, install a cooling fan in the FAN 6 slot, and upgrade both the riser cards (riser1 and riser 2). For more information, see Expansion Card Installation Guidelines.
Power Supplies Your system supports 550 W power supply. When two identical power supplies are installed, the power supply configuration is redundant (1 + 1). In redundant mode, power is supplied to the system equally from both power supplies to maximize efficiency.
3. Press the release latch and pull the power supply straight out to release it from the power distribution board and clear the chassis. Figure 31. Removing and Installing a Power Supply 1.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty.
Removing The Hard-Drive Backplane CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. Press the release tabs and slide the backplane upward. Figure 33. Front View of the Hard-Drive Backplane 1. hard-drive connectors (4) Figure 34. Rear View of the Hard-Drive Backplane 1.
Figure 35. Removing and Installing the Hard-Drive Backplane 1. release tabs (2) 2. hard-drive backplane 3. guide pins (2) 4. chassis hooks (4) 77.
Figure 36. Cabling Diagram 1. system board 2. hard-drive backplane 3. SAS cable connector 4. cable routing guide 5. signal cable connector 6. power cable connector 7. cable routing latch 8. power distribution board 9. cable retention latch Installing The Hard-Drive Backplane CAUTION: Many repairs may only be done by a certified service technician.
Control Panel Assembly Removing The Control Panel CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Installing The Control Panel CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. Remove all the cables connecting the control-panel module to the chassis. CAUTION: Do not use excessive force when removing the control panel as it can damage the connectors. Figure 38. Removing and Installing the Control-Panel Module 1. control-panel module 2.
5. Install the control panel. 6. Reconnect the system and peripherals to their power sources, and turn them on. 7. If applicable, install the front bezel. Power Distribution Board Shroud Removing The Power Distribution Board Shroud CAUTION: Many repairs may only be done by a certified service technician.
3. Lift the power distribution board (PDB) shroud away from the system. Figure 39. Removing and Installing the PDB Shroud 1. PDB shroud tabs (2) 2. PDB shroud 3. arrow marked on the PDB shroud Installing The Power Distribution Board Shroud CAUTION: Many repairs may only be done by a certified service technician.
Power Distribution Board Removing The Power Distribution Board CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
8. Remove the two screws securing the power distribution board to the chassis and lift the board out of the chassis. Figure 40. Removing and Installing the Power Distribution Board 1. screws (2) 2. power supply cables to the system board (3) 3. power supply cable to the hard-drive backplane 4.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. System Board Removing The System Board CAUTION: Many repairs may only be done by a certified service technician.
7. Hold the system board by its edges and lift the system board out of the chassis. Figure 41. Removing and Installing the System Board 1. screws (9) 2. system board Installing The System Board CAUTION: Many repairs may only be done by a certified service technician.
6. Replace the following: a. expansion card holder b. expansion-card risers c. expansion cards d. integrated storage controller card e. internal dual SD module f. PDB shroud g. cooling shroud 7. Reconnect all cables to the system board. NOTE: Ensure that the cables inside the system are routed secured using the cable securing latches.
4 Troubleshooting Your System Safety First—For You And Your System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to the system. 7. Power down all attached USB devices and disconnect them from the system. 8. Reboot the system and, if your keyboard is functioning, enter the System Setup.
Troubleshooting A Wet System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
3. Ensure that the following components are properly installed: • Cooling shroud • Expansion cards • Power supply(s) • Cooling fans • Processor(s) and heat sink(s) • Memory modules • Hard-drive carriers • Hard-drive backplane 4. Ensure that all cables are properly connected.
If the problem persists, see Getting Help . Troubleshooting Cooling Problems CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
4. Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if needed. If the memory settings match the installed memory but a problem is still indicated, go to step 12. 5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Troubleshooting An SD Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you proceed, back up all files on the hard drive. 1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics . Depending on the results of the diagnostics test, proceed as needed through the following steps.
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. b. Open the system. c. Reinstall one of the expansion cards. d. Close the system. e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics .
Troubleshooting Processors CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
5 Using System Diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss.
Menu Description System Health Provides the current overview of the system performance. Event Log Displays a time-stamped log of the results of all tests run on the system.
6 Jumpers And Connectors System Board Jumper Settings For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password. Table 5. System Board Jumper Settings Jumper Setting Description PWRD_EN (default) The password feature is enabled (pins 2–4).
System Board Connectors Figure 42. System Board Jumpers and Connectors Item Connector Description 1 INT_STORAGE Storage controller card connector 2 ID_BTN System identification button 3 CMA_JACK Syste.
Item Connector Description 15 B1, B4, B2, B5, B3, B6 Memory module sockets 16 FAN4 Cooling fan connector 17 FAN3 Cooling fan connector 18 PWR_CONN_1 8-pin power connector 19 FAN2 Cooling fan connector.
6. Open the system. 7. Install the jumper plug on the password jumper. 8. Close the system. 9. Assign a new system and/or setup password. 104.
7 Technical Specifications Processor Processor type One or two Intel Xeon processors E5-2400 v2 product family Expansion Bus Bus type PCI Express Generation 2 and 3 Expansion slots using riser card: R.
Drives NOTE: Four-hard-drive systems support software RAID. For more information on software RAID, see the Dell PowerEdge RAID Controller (PERC) documentation at dell.com/storagecontrollermanuals . Connectors Back NIC Two 10/100/1000 Mbps Serial 9-pin, DTE, 16550-compatible USB Two 4-pin, USB 2.
Power Heat dissipation NOTE: Heat dissipation is calculated using the power supply wattage rating. 2132 BTU/hr maximum (redundant, 550 W power supply) Voltage NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
Expanded Operating Temperature • Maximum altitude for the operating temperature must be 3050 m (10,000 ft). Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets .
Environmental 4572 m (15,000 ft) per MIL-STD-810G, Method 500.5, Procedure II Storage 12,192 m (40,000 ft). Operating Altitude De-rating Up to 35 °C (95 °F) Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft).
8 System Messages LCD Messages NOTE: Applicable only if your system has an LCD display. The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.
NOTE: In some messages, a particular system component is identified by name (“<name>”) component number (“<number>”), or location (“bay”). Error Code Message Information AMP0302 Message The system board < name > current is greater than the upper warning threshold.
Error Code Message Information Details The operating system or an application failed to communicate within the time-out period. The system was shut down. Action Check the operating system, application, hardware, and system event log for exception events.
Error Code Message Information Action Review the logs for fan failures. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heat sink. If the problem persists, see Getting Help . CPU0005 Message CPU < number > configuration is unsupported.
Error Code Message Information Action 1. Turn off the system and remove input power for one minute. 2. Ensure the processor is seated correctly. 3. Reapply input power and turn on the system. 4. If the issue persists, see Getting Help . CPU0701 Message CPU < number > protocol error detected.
Error Code Message Information Action 1. Check system and operating system logs for exceptions. If no exceptions are found, continue. 2. Turn off the system and remove input power for one minute. 3. Ensure the processor is seated correctly. 4. Reapply input power and turn on the system.
Error Code Message Information HWC1001 Message The < name > is absent. LCD Message The < name > is absent. Check hardware. Details The absent device may be necessary for proper operation. System functionality may be degraded. Action Reinstall or reconnect the hardware.
Error Code Message Information MEM0007 Message Unsupported memory configuration; check memory device at location < location >. LCD Message Unsupported memory configuration. Check memory < location >. Details The memory may not be seated correctly, misconfigured, or has failed.
Error Code Message Information MEM8000 Message Correctable memory error logging disabled for a memory device at location < location >. LCD Message SBE log disabled on < location >. Re-seat memory. Details Errors are being corrected but no longer logged.
Error Code Message Information PCI1342 Message A bus time-out was detected on a component at slot < number >. Details System performance may be degraded, or system may fail to operate. Action Cycle input power, update component drivers, if device is removable, reinstall the device.
Error Code Message Information PST0128 Message No memory is detected. LCD Message No memory is detected. Inspect memory devices. Details System BIOS was unable to detect memory in the system. Action Re-seat the memory modules. If the issue persists, see Getting Help .
Error Code Message Information LCD Message Power supply < number > is incorrectly configured. Check PSU. Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review proper configuration in this manual.
Error Code Message Information Action Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. PSU0034 Message An under voltage fault detected on power supply < number >.
Error Code Message Information LCD Message PSU wattage mismatch; PSU < number > = < value >watts Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review this manual for proper configuration.
Error Code Message Information LCD Message System power demand exceeds capacity. System halted. Details The system halted because system power exceeds capacity. Action Review system configuration, upgrade power supplies or reduce system power consumption.
Error Code Message Information LCD Message Internal Dual SD Module < name > failed. Check SD Card. Details The SD card module is installed but improperly configured or failed to initialize. Action Reinstall the SD module and remove and reinstall SD cards.
Error Code Message Information Details If the system event log fails to initialize, platform status and failure events are not captured. Some management software do not report platform exceptions. Action Reboot the management controller or iDRAC. Cycle system input power.
Error Code Message Information LCD Message System inlet < name > temperature is outside of range. Check Fans. Details Ambient air temperature is too warm or one or more fans may have failed. Action Check the system operating environment and review event log for fan failures.
9 Getting Help Contacting Dell NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dell R420xr è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dell R420xr - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dell R420xr imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dell R420xr ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dell R420xr, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dell R420xr.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dell R420xr. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dell R420xr insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.