Manuale d’uso / di manutenzione del prodotto E08J Series del fabbricante Dell
Vai alla pagina of 55
Dell PowerVault MD3860f Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents 1 About your system................................................................................................ 6 Introduction ...............................................................................................................
Removing A Physical Disk From A Physical-Disk Drawer ............................................................ 30 Installing A Physical Disk In A Physical-Disk Drawer .................................................................... 31 SAS Chain Cables .
ECC Errors ..................................................................................................................................... 50 PCI Errors ............................................................................................
1 About your system Introduction CAUTION: See the Safety, Environmental, and Regulatory Information document for important safety information before following any procedures listed in this document. The Dell PowerVault MD3860f RAID storage array (16 Gbps Fibre Channel) is a 4U rack-mounted system, capable of accommodating up to sixty 3.
• Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about configuring and managing the system using the MDSM GUI. • Dell PowerVault MD Series Storage Arrays CLI Guide — Provides information about configuring and managing the system using the MDSM CLI.
Front-Panel Indicators Figure 2. Front-Bezel Indicators Figure 3. Front-Panel Indicators 8.
Item Indicator Icon Description 1 Power-on indicator The power-on indicator lights green when at least one power supply module is supplying power to the storage enclosure. 2 Standby power indicator The standby power indicator lights green when the system is in standby mode and the main power is off.
Item Indicator Icon Description 8 Drive activity indicator NOTE: The associated physical disk is indicated by a number (0 to 11) that is displayed above the drive activity indicator. For example, for physical disk 2 on the physical disk drawer, the drive activity indicator has 2 displayed above the drive activity indicator.
Cooling Fan Module LED Indicator Codes Figure 5. Cooling Fan Module Indicators Item Indicator Icon Description 1 Power indicator The power indicator lights green when power to the cooling fan module is available. 2 Service action required indicator The Service action required indicator lights amber when there is a fault in the cooling fan module.
Power Supply Module Features And Indicators NOTE: Your storage array is shipped with two IEC C19 to C20 jumper cords. Connect the C19 plug to the array's power supplies and the C20 plug to the power distribution unit (PDU) in the rack cabinet. Figure 6.
Item Indicator or Connector Icon Description Off Indicates that you cannot remove the power supply module from the system. 6 Service action required indicator The service action required indicator lights amber when there is a fault in the power supply module.
Item Indicator Icon Description 1 Service action allowed indicator CAUTION: Remove the physical disk from the system only if the service action allowed indicator lights blue. Removing the physical disk from the system when the service action allowed indicator is off may damage the system.
2 Controller Modules RAID Controller Modules RAID controller modules provide high-performance, advanced virtual disk configuration, and fault- tolerant disk subsystem management. Each RAID controller module contains 4 GB of mirrored cache for high availability and is protected by a battery powered cache offload mechanism.
Item Indicator, Button, or Connector Icon Description 3 12 Gbps SAS IN port (2) Provides host-to-controller SAS connection. 4 USB port Reserved port. 5 Mini USB port Dell support only.
SFP+ Transceivers Fibre Optic And SAS Cables NOTE: Your small form-factor pluggable (SFP+) transceivers and cables may look different from the ones shown below. The differences do not affect the performance of the SFP+ transceivers. FC host connections may operate at 4 Gbps, 8 Gbps, or 16 Gbps.
Figure 10. SAS Cable 1. mini SAS connector 2. SAS cable 3. mini SAS HD connector Expansion Controller Modules Use the expansion controller modules to expand the storage capacity up to a maximum of 120 disks (180 disks with premium feature), by daisy-chaining your storage enclosure with up to two MD3060e expansion enclosures.
Item Indicator, Button, or Connector Icon Description 5 SAS OUT port Provides SAS connection for cabling to a downchain expansion enclosure. 6 Diagnostic LED The numeric display consists of two seven-segment LEDs that provide information about enclosure identification and diagnostics.
Table 2. Shutdown Threshold Type Threshold Temperature Exceeding Event Description Nominal failure threshold A critical event is set Maximum failure threshold Shutdown of the system power supplies occ.
3 Installing and removing system components Recommended Tools You may need the following items to perform the procedures in this section: • #2 Phillips screwdriver • T8 and T15 Torx screwdrivers .
Figure 12. Removing and Installing the Front Bezel 1. release latches (2) 2. front bezel 3. guide pins (4) Removing The Front Bezel You must remove the front bezel to access the disk drawers, which enables you to remove and install physical disks in the system.
Figure 13. Inside the Physical-Disk Drawer 1. release latch (2) 2. physical-disk bay (12) 3. physical-disk connector (12) 4. SAS cable connection (2) 5. physical-disk drawer release tab (2) Opening The Physical-Disk Drawer CAUTION: Many repairs may only be done by a certified service technician.
Figure 14. Opening and Closing the Physical-Disk Drawer 1. physical-disk drawer 2. release latch Closing The Physical-Disk Drawer CAUTION: Many repairs may only be done by a certified service technician.
For more information, see the Dell PowerVault MD Series Storage Arrays Administrator's Guide at dell.com/powervaultmanuals . 2. Remove the front bezel. 3. Remove both the SAS cable chains from the back of the chassis. 4. Open the physical-disk drawer.
Figure 15. Removing and Installing the Physical-Disk Drawer 1. physical-disk drawer 2. release tab Installing The Physical-Disk Drawer CAUTION: Many repairs may only be done by a certified service technician.
6. Install the front bezel. 7. Using the MD Storage Manager, verify that the new physical-disk drawer is identified and operating correctly. Physical Disks Your system supports up to sixty 2.5 inch or 3.5 inch SAS and nearline SAS physical disks and 2.
Figure 17. Removing and Installing the 2.5 Inch Physical Disk in a 2.5 Inch Physical-Disk Carrier 1. 2.5 inch physical drive cage 2. guide pin (4) 3. release handle 4.
Figure 18. Removing and Installing the 3.5 Inch Physical Disk in a 3.5 Inch Physical-Disk Carrier 1. 3.5 inch physical disk 2. release handle 3. holes on physical disk (4) 4.
Removing A Physical Disk From A Physical-Disk Drawer CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
7. release tab (12) Installing A Physical Disk In A Physical-Disk Drawer CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
3. SAS chain cable (two per physical-disk drawer) Removing The SAS Chain Cable(s) CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 21. Removing and Installing the SAS Chain Cable(s) 1. left cooling fan module bay 2. right cooling fan module bay 3. SAS cable connector on the midplane (two per physical disk drawer) 4. SAS cable connector to the midplane (oriented vertically) 5.
CAUTION: If you are hot swapping the SAS cable chains, ensure that you complete the procedure on one side within ten minutes to avoid over heating of the storage enclosure. 2. Locate and identify the SAS chain cables for the new physical-disk drawer. 3.
Figure 22. Removing and Installing a RAID Controller Module or Expansion Module 1. RAID controller module or expansion module 2. release lever 3. release tab Installing A RAID Controller Module Or Expansion Module CAUTION: Many repairs may only be done by a certified service technician.
Opening The RAID Controller Module CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Replacing The SFP+ Transceiver CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
RAID Controller Module Backup Battery Unit The battery backup unit provides backup power to the RAID controllers in case of power failure. It ensures power backup for at least 30 minutes to facilitate moving of memory stored in the controller cache to persistent storage.
Installing The RAID Controller Module Backup Battery Unit You must replace the RAID controller battery backup unit immediately to ensure the security of the data in the controller cache memory. CAUTION: Many repairs may only be done by a certified service technician.
NOTE: The Service action required indicator lights amber when there is a fault in the power supply module. 2. Disconnect the power cable from the power source and the power supply module you intend to remove and remove the cables from the cable securing strap.
CAUTION: When connecting the power cable, secure the cable with the cable securing bracket. NOTE: When installing or hot-swapping a new power supply module, allow several seconds for the system to recognize the power supply module and determine its status.
Figure 27. Removing and Installing the Cooling Fan Module 1. cooling fan module release latch 2. cooling fan module handle 3. cooling fan module Installing A Cooling Fan Module CAUTION: Many repairs may only be done by a certified service technician.
4 Troubleshooting your system Safety first—for you and your system CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
NOTE: Equip yourself with antistatic protection and a replacement small form-factor pluggable (SFP +) transceiver before replacing an SFP+ transceiver in the RAID controller module. Also, see the initial setup information for the enclosure to verify LED definitions.
8. Reconnect the fiber optic cable. 9. View the FC IN speed LEDs and the Physical Disk Channel speed LEDs. Based on the LED status, perform one of these actions: • If at least one of the FC IN LEDs for each port is on, go to step 11. • Both the FC IN LEDs on an MD storage array RAID controller module enclosure for a particular port are off.
NOTE: After installing a power supply module, allow several seconds for the array to recognize the power supply module and to determine if it is working properly. If the problem is not resolved, see Getting Help . Troubleshooting Array Cooling Problems CAUTION: Many repairs may only be done by a certified service technician.
If The Link Status LEDs Are Not Green 1. Turn off the host server. 2. Reseat the cables on the expansion array and the server. 3. Turn on the expansion arrays and then the storage array and wait until the system is fully booted. 4. Turn on the host server.
4. Reinstall the physical disk. 5. If the problem is not resolved, replace the failed physical disk. If the problem persists, see Getting Help . Troubleshooting Array And Expansion Enclosure Connections 1. Verify the following: • the SAS OUT status LED is green 2.
Troubleshooting A Damaged Array CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
• One RAID controller module in a redundant configuration has failed • A battery has failed or has been removed • A physical disk in a redundant virtual disk has failed Invalid Storage Array The RAID controller module is supported only in a Dell-supported storage array.
5 Technical Specifications Physical Disks Physical disks Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDs RAID Controller Modules RAID controller modules Two ho.
Back-Panel Connectors (Per RAID Controller Module) NOTE: SAS and FC connections to the same host is not supported. Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time.
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets . Temperature Operating Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH), with 26 °C maximum dew point.
54.
6 Getting help Locating your system service tag Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of a physical DR Series system by pulling out the information tag.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dell E08J Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dell E08J Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dell E08J Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dell E08J Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dell E08J Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dell E08J Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dell E08J Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dell E08J Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.