Manuale d’uso / di manutenzione del prodotto 4E769B del fabbricante Dayton
Vai alla pagina of 16
Operating Instructions & Parts Manual Dayton Pr opane Construction Heater Description Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater uses propane gas for combustion and electricity to run the motor. It is primarily intended for temporary heating of buildings under construction, alteration, or repair.
Dayton Operating Instructions and Parts Manual 2 Dayton Pr opane Construction Heater ® 4E769B General Safety Information Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 3 Model 4E769B Version B - For Reduction G016.J ® Specifications ELECTRICAL SPECIFICA TIONS Electrical Input Amperage 120 V olt/60Hertz 2 General Safety.
Dayton Operating Instructions and Parts Manual 4 Dayton Pr opane Construction Heater ® 4E769B Product Identification Figure 2 – Model 4E769B Shell Handle Motor Power Cord Hot Air Outlet (Front) Fan.
Dayton Operating Instructions and Parts Manual 5 Model 4E769B Version B - For Reduction G016.J ® A verage T emperature Number of T anks ( o F) at T ank Location (100 pound) 40 ° 1 32 ° 1 20 ° 1 10 ° 1 0 ° 1 -10 ° 2 -20 ° 2 Pr opane Supply Propane gas and propane tank(s) must to provided by the customer .
Dayton Operating Instructions and Parts Manual 6 Dayton Pr opane Construction Heater ® 4E769B Installation Review and understand the warnings in the General Safety Infor - mation Section. They are needed to safely operate this heater . Follow all local codes when using this heater .
Dayton Operating Instructions and Parts Manual 7 Model 4E769B Version B - For Reduction G016.J ® Operation (Continued) NOTE : If not opened slowly , excess-flow check valve on propane tank will stop gas flow . If this happens, close propane supply valve and open again slowly .
Dayton Operating Instructions and Parts Manual 8 Dayton Pr opane Construction Heater ® 4E769B Figure 11 - Removing Motor and Fan Guard from Heater Maintenance (Continued) SERVICE PROCEDURES Never attempt to service heater while it is connected to propane supply , operating, or hot.
Dayton Operating Instructions and Parts Manual 9 Model 4E769B Version B - For Reduction G016.J ® Ignitor Ignitor Mounting Screw Rear Head Figure 15 - Removing Ignitor Mounting Screw and Ignitor 7. Set gap between ignitor electrode and target plate to .
Dayton Operating Instructions and Parts Manual 10 Dayton Pr opane Construction Heater ® 4E769B 4E769B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide follow.
Dayton Operating Instructions and Parts Manual 11 Model 4E769B Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 4E769B Replacement Parts List Reference Number Description Part No.
Dayton Operating Instructions and Parts Manual 12 Dayton Pr opane Construction Heater ® 4E769B Never attempt to service heater while it is connected to propane supply , operating, or hot. Severe burns and electrical shock can occur . T roubleshooting Chart Symptom Possible Cause(s) Corrective Action 1.
Dayton Operating Instructions and Parts Manual 13 Model 4E769B Version B - For Reduction G016.J ® 4E769B Description Part No. 10' Rubber Hose with Brass Fitting LP A1020 U.L. listed. 15' Rubber Hose with Brass Fitting LP A1030 U.L. listed. Propane Gas Regulator LP A2110 U.
Dayton Operating Instructions and Parts Manual 14 Dayton Pr opane Construction Heater ® 4E769B Notes __________________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 15 Model 4E769B Version B - For Reduction G016.J ® 4E769B Notes ________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 16 Dayton Pr opane Construction Heater ® 4E769B 101427-01 Rev . B 01/00 Version B - For Reduction G016.J ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Natural gas construction heater, Models covered in this manual are warranted by Dayton Electric Mfg.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dayton 4E769B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dayton 4E769B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dayton 4E769B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dayton 4E769B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dayton 4E769B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dayton 4E769B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dayton 4E769B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dayton 4E769B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.