Dayton Pr opane Construction Heater Description Dayton Model 3VG80 heater is a variable 65,000, 85,000, and 100,000 Btu/Hr construc- tion heater . This heater uses propane gas for combustion. It is primarily intended for temporary heating of well-ventilated buildings under construction, alteration, or r epair .
Dayton Operating Instructions and Parts Manual 3VG80 2 Dayton Pr opane Construction Heater ® General Safety Information Make certain you read and understand a ll warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3 Model 3VG80 • Locate heater on stable and level surface if heater is hot or operating. • Never block air inlet (rear) or air outlet (front) of heater . • Keep heater away from str ong drafts, wind, water spray , rain, or dripping water .
Dayton Operating Instructions and Parts Manual 3VG80 4 Dayton Pr opane Construction Heater ® Figure 2 - Pr oduct Identification Handle Power Cord Hose /Regulator Assembly Hot Air Outlet (Front) Inlet.
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 5 Model 3VG80 Air For Combustion And Heating Fuel Combustion Chamber Figure 3 - Cross Section Operational V iew Clean.
Dayton Operating Instructions and Parts Manual 3VG80 6 Dayton Pr opane Construction Heater ® Installation Review and understand the warnings in the General Safety Infor - mation section, pages 2 and 3. They ar e needed to safely operate this heater .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 7 Model 3VG80 5. Plug extension cord into a 120 V olt/60 Hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater . 6. Open propane supply valve on pr opane tank(s) slowly .
Dayton Operating Instructions and Parts Manual 3VG80 8 Dayton Pr opane Construction Heater ® Maintenance (Continued) Ground Screw T er minal Board Motor Green Lead T ransfor mer Green Lead Power Cord.
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 9 Model 3VG80 5. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds). 6. Place motor , motor mount, and fan guard into r ear of heater shell (See Motor , page 8, steps 14 through 18).
Dayton Operating Instructions and Parts Manual 3VG80 10 Dayton Pr opane Construction Heater ® Wiring Diagram 100,000 BUT/HR MODEL Black Green White Motor Ignitor Orange Blue Blue Auto Control V alve .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 11 Model 3VG80 T roubleshooting Chart Never attempt to service heater while it is plugged in, connected to pr opane supply , operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 3VG80 12 Dayton Pr opane Construction Heater ® For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Figure 15 - Repair Parts Illustrat.
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 13 Model 3VG80 Repair Parts List ( ) Not shown. (*) Standard har dware item, available locally . 1 Base T ray 102362-01 1 2 *Hex TPG Screw , 10-16 X 38 M11084-26 15 3 Base 103917-01AA 1 4 Nozzle 099138-02 1 5 Shell Kit 098511-216 1 6 *Hex TPG Screw ,10-16 X .
Dayton Operating Instructions and Parts Manual 3VG80 103029-01 Rev . E 10/02 Version B - For Reduction G016.J ® Dayton Pr opane Construction Heater LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton propane construction heater, Models covered in this manual, are warranted by Dayton Electric Mfg.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dayton 3VG80 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dayton 3VG80 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dayton 3VG80 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dayton 3VG80 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dayton 3VG80, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dayton 3VG80.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dayton 3VG80. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dayton 3VG80 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.