DS6500 INSTA LLA TION QUICK REFERENCE.
CONTENTS DS6500-100-010 M ASTER/SLAVE MODEL ........................................................................................................... 1 DS6500-100-011 PROFIBUS MODEL ...................................................................
DS6500 MASTER/SLAVE MODEL DS6500-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Main/Aux.
DS6500 MASTER/SLAVE MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage T.
DS6500 MASTER/SLAVE MODEL The details of the connector pins ar e indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable.
DS6500 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS6500 CAB-600X C-BOX 100 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < *P.S. *P.S. Gryphon DS4600A DS4600A DS6500 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 A U X MAIN *P.
DS6500 MASTER/SLAVE MODEL Multiplexer Layout E N T < < E N T < < *P.S. *P.S. DS4600A DS4600A DS6500 PWR-120 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 MX4000 #0 1 #31 #1 Local Host 1 RS485 HD M ain Interface * P.S. (Presence Sensor) connect ed to External Trigger/PS input.
DS6500 MASTER/SLAVE MODEL Local Lonworks Netw ork CAB-60XX CAB-610X BTK-6000 C-BOX 100** Master Encoder*** BTK-6000 Slave 1 *P.S. Local Host CAB-63XX PWR-120 Small Synchronized Network w ith 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input.
DS6500 MASTER/SLAVE MODEL Large Synchronized Ne tw ork ** * * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to IN2/ENC input.
DS6500 PROFIBUS MODEL DS6500-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Prof ibus 9- pin Female Connector (whit e) 1 Lonworks 9-pin Female Con nector 2 Ma in/Aux.
DS6500 PROFIBUS MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Tempe.
DS6500 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (refe.
DS6500 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 PROFIBUS MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 ETHERNET MODEL DS6500-100-012 ETHERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Ethe rnet Inter fac e 1 Lonworks 9-pi n Female Con nector 2 Ma in/Aux.
DS6500 ETHERNET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Tempe.
DS6500 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (refe.
DS6500 ETHERNET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 ETHERNET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 DEVICENET MODEL DS6500-100-015 DEVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Main/Aux.
DS6500 DEVICENET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temp.
DS6500 DEVICENET MODEL The details of the connector pins ar e indicated in the following table: 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable sh.
DS6500 DEVICENET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 DEVICENET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 OSCILLATING MIRROR MODEL DS6500-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 1 Oscillating mirror models are used when coverage of a lar ge reading area is required, mainly in picket fence applications. The DS6500 scanner mounts a dedicated optic head with int egrated oscillating mirror driven by a linear motor.
DS6500 OSCILLATING MIRROR MODEL In the above case, the zone where the scan line is perpendicular to the reflec ting surface corresponds to a neutral zone at the center of the reading field. The mirror can be deflected up to 40°. Oscillation with res pect to the output window medi an axis is asymmetrical (see figure below).
COMMON FEATURES COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connecto rs. Use this pinout when the DS6500 reader is connected in a netw.
COMMON FEATURES Mechanical Installation: The DS6500 reader can be positioned and in stalled in the best way possible as a result of the Step-A-Head TM feature.
COMMON FEATURES Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST -237 106° mounting bracket w hic h guarantees a built-in Skew angle ( S in the figure below) of 16° w ith respect to the frame plane (typically the Skew angle should be between 10° - 20°).
COMMON FEATURES Minimum Code Height for A CR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1. 5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 10 12 14 16 18 20 7 9 10 12 13 15 0.30 12 14 15 17 19 21 8 9 11 12 14 15 0.33 13 14 16 18 20 22 8 10 11 13 14 16 0.38 14 16 18 19 21 23 9 11 12 14 15 17 0.
COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is t he center of the laser beam output w indow . DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.
COMMON FEATURES Reading Diagrams: DS6500-200-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14 (in) 20 26 32 0 35 50 6 5 80 95 (cm ) 110 38 44 140 56 (in) (c m) 0 -15 -30 -45 -12 -18 -6 0 -60 -24 -75 -30 15 6 30 12 0.
COMMON FEATURES User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connec tor Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How T.
COMMON FEATURES Compliance: Laser Safety Figure A Laser Saf ety Label 1 Identif ication Label 2 Figure B W arning and Device Class Label 1 Figure C Laser Safety Label 1 1 2 1 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.
COMMON FEATURES The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulati ons.
DATALOGIC S.p.A., DATALOGIC S.p.A., 05 Via Candini, 2 Via Candini, 2 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologna - Italy Bologna - Italy dichiara che dichi ara che declares that the .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic Scanning DS6500-100-015 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic Scanning DS6500-100-015 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic Scanning DS6500-100-015 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic Scanning DS6500-100-015 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic Scanning DS6500-100-015, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic Scanning DS6500-100-015.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic Scanning DS6500-100-015. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic Scanning DS6500-100-015 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.