Manuale d’uso / di manutenzione del prodotto C-BOX 200 del fabbricante Datalogic Scanning
Vai alla pagina of 28
C-BO X 200 Installation Manual.
C-BOX 200 INSTA LLA TION MANUA L.
01 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 200, active con nection .
iii CONTENTS GUIDE TO INSTALLA TIO N .............................................................. iv SA F ETY PRECA U TIO NS ................................................................. vii Power Supply .........................................
iv GUIDE TO INSTA LLA TI ON The following can be used as a check list to verif y all of the steps neces sary for c om plete installation of the C- BOX 200. 1) Read all inf orm ation in the sec tion "Safety Precautions" at the beginning of this m anual.
v C-BOX 200 General View 1 2 3 Figure A 25-pin scan ner connector Cover screws (4) Compression connectors 1 2 3.
vi C-BOX 200 General View 4 10 1 2 6 7 8 9 12 5 3 11 Figure B Pow er swit ch (ON /OFF) 1 2 Spring clamp terminal b locks 3 Mul tidrop address switches 5 4 Po wer on LED Wa rn i ng LE D 6 Tx LE D 7 GET.
vii SA FETY PRECA UTIONS POWER SUPPLY ATT ENTION: READ THIS INFORMATION BEFORE INST AL LING THE PRODUCT - This product is intended to be ins talled by Qualified Personnel only. The C-BO X 200 is intended to be s upplied by an NEC Class 2 power source, rated 10-30 V, m inim um 0.
viii.
DA TA LOGIC C-BOX 200 General Features - 1 1 GENERA L FEA TURES 1.1 DESCRIPTION The C-BO X 200 is a c onnection box which c an be used as an acces sory of the Datalogic scanner s to perf orm the following func tions: • Facilitate the connection of the scanner s ignals using a spr ing clam p connector.
C-BOX 200 DA TALOGIC 2 - Installa tion 2 INSTA LLATION 2.1 PACKA GE CONTENTS Verify that the C-BOX 200 and all the parts supplied with the equipm ent are present and intact when opening the pack aging; the list of parts inc ludes: 1) C-BOX 200 2) Installation m anual 1 2 Figure 2.
DA TA LOGIC C-BOX 200 Installatio n - 3 2.2 OPENING THE DEVIC E To install the C-BOX 200 or during nor mal m aintenanc e, it is neces sary to open it by unscrewing the f our cover s crews: WA RNING The C-BO X 200 m ust be disconnec ted f rom the power supply during this operation.
C-BOX 200 DA TALOGIC 4 - Installa tion 2.3 MECHANICA L INSTA LLATION The diagram below gives the overall dim ensions of the C-BOX 200 and m ay be used for its installation.
DA TA LOGIC C-BOX 200 Installatio n - 5 C-BOX 200 c an be installed to operate in dif fer ent positions. T he two s crew holes inside the housing of the C-BOX 200 are f or m echanical f ixture ( Figure 2.4). To m ount the C-BO X 200: 1) Open the C-BOX 200 by unscrewing the 4 cover sc rews.
C-BOX 200 DA TALOGIC 6 - Installa tion 2.4 ELE CTRICA L CONNECTIONS AND SETUP The following figure shows the ty pical layout. The dotted line in the figure refer s to an optional hardware conf iguration. PC SCANNER System C ables Scanner Auxiliary Interface Figure 2.
DA TA LOGIC C-BOX 200 Installatio n - 7 2.4.1 Powe r Supply Power is supplied to the C-BOX 200 through the pins provided on the spring clam p connector. The power switch (see F igure 2.6) switches the power supply ON or OFF for both the C-BOX 200 and the c onnected sc anner.
C-BOX 200 DA TALOGIC 8 - Installa tion 2.4.2 Sy stem Wiring The c onnection and wiring procedure f or C-BO X 200 is des cribed as f ollows: 1) Open the C-BOX 200 as desc ribed in paragraph 2.2. 2) Verify that the C-BOX 200 power switch is off (see F igure 2.
DA TA LOGIC C-BOX 200 Installatio n - 9 The C-BO X 200 spr ing clam p connector pinouts are indicated in the f ollowing table. Refer to the sc anner Installation Manual for deta ils.
C-BOX 200 DA TALOGIC 10 - Installa tion 2.4.3 Chassis Grounding Jumper Settings The s canner chas sis grounding m ethod c an be selected by positioning a jum per (see Figure 2.9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connec ted to a good earth ground) or to the power supply gr ound signal.
DA TA LOGIC C-BOX 200 Installatio n - 11 2.4.4 Multidrop A ddress Selection For RS485 half -duplex interf ace connec tions, the sc anner m ultidrop addr ess should be set using the r otary switches placed inside the C-BOX 200. The valid addr ess range is fr om 00 to 31.
C-BOX 200 DA TALOGIC 12 - Installa tion 2.4.5 RS485 Bus Terminat ion ON S2 OFF Figure 2.11 - Terminati on resistance swi tch The switch S2 enables or disables the insertion of the bus term ination resistor for RS485 Half Duplex Multidr op applications.
DA TA LOGIC C-BOX 200 Installatio n - 13 2.4.6 Connection to a Multiplexer The f ollowing figure shows a m ultidrop layout with C-BOX 200 devices connected to a Multiplexer : MULTIP LEX ER C-BOX 20 0 .
C-BOX 200 DA TALOGIC 14 - Installa tion 2.4.7 OM4000 Jumper Sett ings J1 J2 Figure 2.13 - OM 4000 jumpers The jum pers allow c onnection to the EXT TRIG signals on separ ate spring clam p terminals for applic ations which use the O M4000 Osc illating Mirror in Trigger Mode.
DA TA LOGIC C-BOX 200 Installatio n - 15 2.5 9-PIN SCA NNER A UXILIA RY SERIA L INTERFA CE The s canner auxiliar y serial interface available on the internal 9-pin connector c an be used either f or conf iguration through W inHost or for data monitor ing.
C-BOX 200 DA TALOGIC 16 - Installa tion 2.6 SCANNER REQUIREMENTS 1) T he C-BOX 200 c an be connected to the f ollowing scanners thr ough the 25-pin connector illustrated in F igure A.
DA TA LOGIC C-BOX 200 Installatio n - 17 2.7.1 GET/SEND Butt ons The C-BO X 200 has two internal function buttons (GET , SEND) . T he procedure to enable the G ET/SEND f unction is the f ollowing: 1. Press both the buttons GET and SEND at the same tim e for at least one second; the warning LED is tur ned ON.
C-BOX 200 DA TALOGIC 18 - Installa tion 2.7.2 LED Indicators Power on Wa rn i ng Tx Figure 2.15 - LED Indicators The three internal LEDs of the C-BO X 200 (see F igure 2.15) indicate the following: POWER ON (red) indic ates the C-BOX 200 is connec ted to the power supply and the pow er switch is O N.
DA TA LOGIC C-BOX 200 Technical Features - 19 3 TECHNICA L FEA TURES ELECTRICAL FEA T URES Power Supply volt age 10 to 30 Vdc Power consum ption m ax. 1.4 W + s canner USER INTERFACE LED indi cators Pow er ON , W arni ng, Tx (RS485 Multidrop activi ty) P H Y SI C AL F EAT U R E S Mechanical di mens ions 167 x 115 x 40 mm (6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic Scanning C-BOX 200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic Scanning C-BOX 200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic Scanning C-BOX 200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic Scanning C-BOX 200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic Scanning C-BOX 200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic Scanning C-BOX 200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic Scanning C-BOX 200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic Scanning C-BOX 200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.