www .automation.dat alogic.com C-BO X 150 Inst allation Manual.
Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy C-BOX 150 Ed.: 07/2007 ALL RIGHTS RESERVED Datalogic reserves the right to make modifi cati ons and improvements without prior notification.
CONTENTS 1 INTRODUCTION .......................................................................................... 1 1.1 Product Description ....................................................................................... 1 1.2 C-BOX 150 Compatible Dev ices .
SAFETY PRECAUTIONS POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING T HE PRODUCT - This product is intended to be installed by Qualified Perso nnel only. The C-BOX 150 is intended to be supplied either by a UL Listed NEC Class 2 po w e r source, or a UL Listed IT E Limited Power Source (LPS), rated 10-30 V dc, minimum 0.
ITALIANO Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che rip orta il simbolo del bidone barrat o deve essere smaltita, alla fine della sua vita utile, separatamente dai rif iuti urbani.
GENERAL VIEW C-BOX 150 2 3 1 Figure A 25-pin scanne r connector Cover screws (4) Compression conn ectors 1 2 3 vi.
C-BOX 150 9 2 11 12 7 8 15 1 17 18 4 5 10 13 6 3 16 14 Figure B - Bottom Inside Power on switch 1 2 Chassis gr ounding jumper 3 Power polarity er ror LED (red) 5 4 RS485 Bus term in.
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the C-BOX 150. 1) Read all information in the section "S afety Precautions" at the beginning of this manual.
INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The C-BOX 150 is a connection box w hic h can be used as an accessory to several Datalogic family scanners. Its main feature is to make the substituti on of a Datalogic scanner in an installation plain and easy.
C-BOX 150 1 1.2 C-BOX 150 COMPATIBLE DEVICES The C-BOX 150 can be co nnected to the following scanners through the 25-pi n connector illustrated in Figure A.
INSTALLATION 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the C-BOX 150 an d all the parts supplied with the equipment are present and intact when opening the packagin g; the list of parts includ.
C-BOX 150 2 2.2 OPENING THE DEVICE To install th e C-BOX 150 or during normal ma intenance, it is necessary to open it by unscrewing the four cover screws: CA UTION The C-BOX 150 must be disconnected from the power supply during this operation.
INSTALLATION 2 2.3 MECHANICAL INSTALLATION The diagram belo w gives the overall dimensions of the C-B OX 150 and may be use d for its installation. mm inch Ø3.5 [Ø0.14] 12 [0.47] 66 [2.60] 12 [0.47] 5 [0.20] 150 [5.91] 5 [0.20] 40 [1.57] 161 [6.34] 90 [3.
C-BOX 150 2 C-BOX 150 can be installed to operate in different positions. The t w o screw holes inside the housing of the C-B OX 150 ar e for mechanical fixture (Figure 4). To mount the C-BOX 150: 1) Open the C-BOX 150 b y uns crewing the 4 cover screws.
INSTALLATION 2 2.4 ELECTRICAL CONNE CTIONS AND HARDWARE SETUP The following figure shows the typical layout. SCANNER A UXILIARY INTERFACE C-BOX 150 SCANNER SCANNER CONFIGURATION PC SYSTEM CABLES Figur.
C-BOX 150 2 After system functioning has been verified , close the C-BOX 150 using the 4 cover screws making sure the rubber seal is fi tted correctly between the parts of the housing. NOTE It is recommended to use the dedicated grounding cable (included i n the package) to improve the C-BOX 150 noi se immunity.
INSTALLATION 2 C-BOX 1 2 VS GND USER INTERFACE GND V+ (10 - 30 Vdc) Figure 7 - Power Suppl y Conne ctions The power supp ly must b e bet w een 10 and 30 Vdc only. NOTE Pin 1 is also electrical ly connected to pins 3 and 5, just as pin 2 is electrically connected to pins 4 and 6.
C-BOX 150 2 • Using a device such as a screwdriver, push down on the lever d irectly next to the clamp (see Figure 8). • Insert the wire into the clamp and release the lever. The wire will now be held in the spring clam p. Figure 8 - System Cab le Connections The wiring used can be solid or strande d but must meet the following specifications.
INSTALLATION 2 The C-BOX 150 spring clamp connector pinout s are indicated in the follo w ing tabl e. Refer to the scanner Reference Manual for details.
C-BOX 150 2 2.4.3 Scanner Chassis Grounding Jumper Settings The scanner chassis grounding method can be sel ected by positioning a jumper (see Figure 9). In this w ay the sca nner chassis can be connected to earth gr ound (only if pins 7 or 8 are connecte d to a good earth ground) or to the po w er suppl y ground signal.
INSTALLATION 2 2.4.5 RS485 Bus Termination ON OFF Figure 11 - Termina tion Resistance Switch This swi tch enables or disa bles the insertion o f the bus terminatio n resistor for RS485 Half Duplex Multidrop appl ications.
C-BOX 150 2 2.4.7 OM4000 Jumper Settings J6 J5 Figure 13 - OM4000 Jumpers The jumpers allo w connection to the EXT TRIG signals on separate spring clamp terminals for applications w hich use the OM4000 Oscillati ng Mirror in Trigger Mode.
INSTALLATION 2 9-pin C-Box 150 con nector pinout in Normal mode Pin Name Function 1 NC 2 RXA Auxiliary RS232 3 TXA Auxiliary RS232 4 NC 5 GND Ground 6 NC 7 RESERVED Device Dependent Signal 8 RESERVED Device Dependent Signal 9 NC POSITION MODE CFG : When the switch is i n this position, the C-BOX 150 can b e configured.
C-BOX 150 2 2.5 OPERATING MODES With the C-BOX 150, the follow ing oper ating modes are possible: Normal Operation: At power on, the C-BOX 150 trie s to connect to the scanner. Once the connection procedur e is completed the C-BOX 150 verifies if an Automatic SEND command must be executed.
INSTALLATION 2 2. Release the buttons. 3. Press the left button correspondin g to the GET function, the center button corresponding to the T EST function or the right button co rresponding to the SEND function. NOTE Once the buttons are released in ste p 1, a ten-second timeout starts.
C-BOX 150 2 2.5.2 LED Indicators Warning (red) Pow n) er on (gree Power polarity error (red) TX (green) Status (yellow) Figure 16 - LED Indicators The internal LEDs of the C-BOX 150 (see F igure above) indicate the following: POWER ON ( PWR ) (green) indicates the C-BOX 150 is connected to the power supply and the power switch is ON.
INSTALLATION 2 1 blinking/sec: a requested operation has been terminated abnormally. 2 blinking/sec: a w r ong operation has been requ ested (for example the configuration in memory is not compatible with the connected scanner). STATUS ( SL ) (yellow) indicates the status of the non-v olatile memory support.
C-BOX 150 2 2.6 TYPICAL LAYOUTS 2.6.1 1000, 2000A/N, 4000 Family Scanners For 1000, 2000A/N and 400 0 scanner families which operate in a point-to-point single scanner configuration, a typical layo ut is shown below and the C-B OX 150 is connected as follows.
INSTALLATION 2 2.6.2 2000N Family Scanners For 2000N scanner families which operate in an ID-NET™ network configuration, a typical layout is sho wn below and the C- BOX 150/100s are connected as follo w s.
C-BOX 150 2 2.6.3 6000, 8000 Family Scanners For the 6000 and 8000 scanner families, th e C-BOX 150 can operate in both point-to- point single scanner configur ation layouts, and in a netwo rk cluster of scanners in Master/Slave layouts.
INSTALLATION 2 In order to perform Backup/Restore of Master only, the C-BOX 150 Cluster GET/SEND parameter must be co nfigured to "Master only", see the WinHost Help On-Line . 2.7 SCANNER REPLACEMENT If you have to replace the scanner with another on e: 1.
C-BOX 150 3 3 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply voltage 10 to 30 Vdc Power consumption max. 2.5 W + scanner USER INTERFACE LED ind icat ors Power ON, Warning, Status Tx, Po larity invers ion PHYSICAL FEATURES Mechanical dimensions 161 x 114.
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät decl.
www .automation.dat alogic.com C-BO X 150 Inst allation Manual.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic Scanning C-BOX 150 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic Scanning C-BOX 150 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic Scanning C-BOX 150 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic Scanning C-BOX 150 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic Scanning C-BOX 150, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic Scanning C-BOX 150.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic Scanning C-BOX 150. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic Scanning C-BOX 150 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.