C-BO X 200 Installation Manual.
C-BOX 200 INSTA LLA TION M A NUA L.
01 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderar a Bologna - Italy dichia ra che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 200, activ e connectio.
iii CONTENTS GUIDE T O INST A LLA TIO N .............................................................. iv SA F ETY PRECA UT ION S ................................................................. vii Power Supply ......................................
iv GUIDE TO INSTA LLA TION The f ollowing c an be used as a check lis t to verify all of the steps nec essa ry for com plete installation of the C-BOX 200. 1) Read all infor m ation in the section "Saf ety Prec autions" at the beginning of this m anual.
v C-BOX 200 General View 1 2 3 Figure A 25-pin scanner connector Cover screw s (4) Compression co nnectors 1 2 3.
vi C-BOX 200 General View 4 10 1 2 6 7 8 9 12 5 3 11 Figure B P owe r swi tch (ON/ OFF) 1 2 Spring clam p ter m inal b locks 3 Mul tidrop address switches 5 4 Po wer on LED Wa rn i n g L ED 6 Tx LE D .
vii SA FETY PRECA UTIONS POWER SUPPLY ATT ENTION: READ THIS INFORMAT ION BEFORE INSTALLING THE PRODUCT - This product is intended to be installed by Qualified Pers onnel only . The C- BOX 200 is intended to be supplied by an NEC Class 2 power sour ce, rated 10-30 V, m inim um 0.
viii.
DA TA LOGIC C-BOX 200 General Features - 1 1 GENERA L FEA TURES 1.1 DESCRIPTION The C- BOX 200 is a connection box which can be used as an ac cess ory of the Datalogic sc anners to per form the f ollowing functions : • Facilitate the connection of the scanner signals using a s pring clam p connector .
C-BOX 200 DA TA LOGIC 2 - Insta llation 2 INSTA LLA TION 2.1 PA CKA GE CONTENTS Verify that the C-BO X 200 and all the parts supplied with the equipm ent are present and intac t when opening the packaging; the lis t of par ts includes: 1) C-BO X 200 2) Installation m anual 1 2 Figure 2.
DA TA LOGIC C-BOX 200 Installa tion - 3 2.2 OPENING THE D EVICE To install the C-BOX 200 or dur ing norm al m aintenance, it is necess ary to open it by unscr ewing the four cover scr ews: WA RNING The C- BOX 200 m us t be dis connected fr om the power supply during this operation.
C-BOX 200 DA TA LOGIC 4 - Insta llation 2.3 ME CHA NICA L INS TA LLA TION The diagram below gives the overall dim ensions of the C- BOX 200 and m ay be used f or its ins tallation.
DA TA LOGIC C-BOX 200 Installa tion - 5 C-BOX 200 can be installed to oper ate in diff erent positions . The two sc rew holes inside the hous ing of the C-BO X 200 are f or m ec hanical f ixture (F igure 2.4). To m ount the C- BOX 200: 1) Open the C-BO X 200 by unsc rewing the 4 c over screws.
C-BOX 200 DA TA LOGIC 6 - Insta llation 2.4 E LECTRICA L CONNECTIONS A ND SETUP The f ollowing f igure shows the ty pical lay out. T he dotted line in the f igure ref ers to an optional hardware c onfiguration. PC SCANN ER System Cables Scanner Auxiliary Interface Figure 2.
DA TA LOGIC C-BOX 200 Installa tion - 7 2.4.1 Pow er Supply Power is supplied to the C-BOX 200 thr ough the pins provided on the sp ring clam p connec tor. The power switch (s ee Figure 2.6) s witches the power supply ON or OFF f or both the C-BOX 200 and the connected s canner.
C-BOX 200 DA TA LOGIC 8 - Insta llation 2.4.2 Sy stem Wiring The c onnection and wiring procedur e for C- BOX 200 is descr ibed as f ollows: 1) Open the C-BO X 200 as des cribed in paragr aph 2.2. 2) Verify that the C-BOX 200 power switch is of f ( see Figure 2.
DA TA LOGIC C-BOX 200 Installa tion - 9 The C- BOX 200 s pring clam p connec tor pinouts ar e indic ated in the f ollowing table. Refer to the s canner Insta llation M anual for de tails.
C-BOX 200 DA TA LOGIC 10 - Insta llation 2.4.3 Chassis Grounding Jumper Settings The s canner c hassis grounding m ethod can be s elected by positioning a jum per (see Figure 2.
DA TA LOGIC C-BOX 200 Installa tion - 11 2.4.4 Mult idrop A ddress Selection For RS485 half -duplex inter fac e connections , the scanner m ultidr op addres s should be set us ing the rotary switches placed inside the C-BO X 200. The valid addr ess r ange is f rom 00 to 31.
C-BOX 200 DA TA LOGIC 12 - Insta llation 2.4.5 RS485 Bu s Termination ON S2 OFF Figure 2.11 - Termin ation resistance sw itch The switch S2 enables or disables the insertion of the bus ter m ination resis tor fo r RS485 Half Duplex Multidrop applications .
DA TA LOGIC C-BOX 200 Installa tion - 13 2.4.6 Connection t o a Multiplexer The f ollowing figure s hows a m ultidrop lay out with C-BOX 200 devic es connected to a Multiplex er: MULT IPLE XE R C-BO X.
C-BOX 200 DA TA LOGIC 14 - Insta llation 2.4.7 OM4000 Jumper Set tings J1 J2 Figure 2.13 - OM 4000 jumpers The jum per s allow c onnection to the EXT T RIG signals on s eparate spr ing clam p term inals for applications which us e the OM4000 Os cillating Mirr or in Tr igger Mode.
DA TA LOGIC C-BOX 200 Installa tion - 15 2.5 9-PIN SCA NN ER A UXILIA RY SERIA L INTER FA CE The s canner aux iliary serial interfac e available on the internal 9- pin connector can be used either for c onfiguration thr ough W inHost or f or data m onitoring.
C-BOX 200 DA TA LOGIC 16 - Insta llation 2.6 S CA NNER RE QUIREMENTS 1) T he C-BOX 200 can be connec ted to the following scanner s through the 25-pin connec tor illustr ated in Figure A.
DA TA LOGIC C-BOX 200 Installa tion - 17 2.7.1 GET/SEND Bu ttons The C- BOX 200 has two internal f unction buttons ( GET , SEND). The procedur e to enable the GET /SEND function is the following: 1. Press both the buttons GET and SEND at the same tim e f or at least one second; the warning LED is turned ON.
C-BOX 200 DA TA LOGIC 18 - Insta llation 2.7.2 LED Indicators Power on Wa r n i n g Tx Figure 2.15 - LED Indicators The three internal LEDs of the C- BOX 200 ( see Figure 2.15) indic ate the following: POWER ON (red) indicates the C-BO X 200 is c onnected to the power supply and the power switch is ON.
DA TA LOGIC C-BOX 200 Technic al Features - 19 3 TECHNICA L FEA TURES ELECT RICA L F EA T URES Power Supply volt age 10 to 30 Vdc Power consum ption m ax. 1.4 W + scanner USER INTERFACE LED indicat ors Pow er O N, Warn ing , Tx (RS485 Multidrop act ivity) P H Y S I C AL F E AT U R E S Mechanical dimens ions 167 x 115 x 40 m m (6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic C-BOX 200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic C-BOX 200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic C-BOX 200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic C-BOX 200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic C-BOX 200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic C-BOX 200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic C-BOX 200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic C-BOX 200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.