INSTALLATION MANUAL R410A Split Series Models 2MXS40G2V1B 2MKS40G2V1B 2MXS40H2V1B 2MKS40H2V1B 2MXS40H3V1B 2MKS50G2V1B 2MXS50G2V1B 2MKS50H2V1B 2MXS50H2V1B 2MXS50H3V1B 2AMX40F2V1B 2AMX40G2V1B 2AMX40G3V1.
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan 3SB64417-5A 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B 2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B D AIKIN INDUSTRIES, L TD.
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan D AIKIN INDUSTRIES, L TD. EN60335-2-40, DAIKIN.TCF .015 P6/07-2012 DEKRA Certification B.
3SB65451-4.fm Page 2 Thursd ay, October 27, 2011 4:49 PM.
1 ■ English Safety Precautions • The precautions descri bed herein are classified as W ARN ING and CAUTION. They both contain important informa - tion regarding safety . Be sure to observe all precau tions without fail. • Meaning of W ARNING and CAUTION no tices W ARN ING .
■ English 2 Accessories Accessories supplied wit h the outdoor unit: Precautions for Selecting the Location 1) Choose a place soli d enough to bear th e weight and vibratio n of the uni t, where the operation noi se will not be ampli fied.
3 ■ English Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the insta llation manual which was provided with the units.
■ English 4 Installation • Install the unit horizontally . • The unit may be installed directly on a concrete verandah or a solid place if drai nage is good. • If the vibration may possibly be transmitted to the bu ilding, use a vibration-pr oof rubbe r (field supply).
5 ■ English Outdoor Unit Installation Guideline • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow , follow the instal lation guidelines be low . • For any of the below installation pattern s, the wall height on the exhaust side should be 120 0mm or less.
■ English 6 Refrigerant Piping W ork 1. Installing outdoor unit 1) When installing the outdoor unit, refer to “Precautions for Se lecting the Location” on page 2 and the “Indoor/Outdoor Unit Installation Drawings” on p age 3. 2) If drain work is ne cessary , follow the procedures below .
7 ■ English Refrigerant Piping W ork 4. Purging air and ch ecking gas leakage WARNING • Do not mix any substance other tha n the specifie d refrigerant (R410A) into the refrigera tion cycle. • When refrigerant gas leaks occur , ventilate the room as soon and as much as possible.
■ English 8 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410 A Fill from th e gas pipe i n liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, p reventing normal operatio n.
9 ■ English Refrigerant Piping W ork Precautions for Laying Refrigerant Piping • Cautions on pipe handling 1) Protect the open end of the pipe against du st and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending.
■ English 10 Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap s on the liquid an d the gas stop valves at the pipes for rooms A and B. 2) Run the unit on forced cooling.
11 ■ English Wir ing WARNING • Do not use tapped wire s, stranded wires ( CAUTION 1)), extension co rds, or starburst co nnections, as they may cau se over- heating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the produc t.
■ English 12 Maximum Power Input Limitation Setting WARNING Always shut off the power supply breaker before starting. • The Maximum Power Input Limitation needs to be set when the unit is installed. • This function limi ts the power input of the unit to 1700W .
13 ■ English ECONO Mode Prohibition Setting WARNING Always shut off the power supply breaker before starting. • This setting disables the inp ut control signal from the remote controller . • Use this setting when you wish to block receptio n of input controls (cooling/heating) from indoor unit remote co ntrollers.
■ English 14 T rial Operation and T esting • Before starting the test run, measure the voltag e at the primary side of the safety breaker . • Check that all liquid and gas stop valves are fully open. • Check that pipi ng and wiring all match. 1.
(1210) HT 3P210724-1F M07B062F Two-dimensio nal bar code is a code for manufact uring. 00_CV_3P210724-1F.fm Page 2 Tu esday, October 30, 2012 10: 36 AM.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Daikin 2AMX50G3V1B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Daikin 2AMX50G3V1B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Daikin 2AMX50G3V1B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Daikin 2AMX50G3V1B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Daikin 2AMX50G3V1B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Daikin 2AMX50G3V1B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Daikin 2AMX50G3V1B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Daikin 2AMX50G3V1B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.