User’s Manual for: UP625 UPS UP825 UPS ADDITIONAL INST ALLA TION TIPS CAN BE F OUND A T : www .cyberpowersystems.com/F AQs.htm.
T ABLE OF CONTENTS IMPORT ANT SAFETY WA RNIN GS …………….…………………… …………………………1 INST ALLING YOUR UPS SYSTEM …………………….………………………………………2 - UNP ACKING…… …………………………… ………………… ……… ……….
UP625/ UP825 Guaranteed Uninterruptible Power System IMPORT ANT SA FETY W ARNINGS (SA VE THESE INSTRUCTIONS) This manual contains import ant instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit.
INST ALLING YOUR UPS SYSTEM UNP ACKING Inspect the UPS upon receipt. The box should contain the following: (1) UPS Unit; (1) PowerPanel Plus Software Disk; (1) Serial Interface Cable (DB-9); (1) T elephone Ca ble; (1) User ’s M anual; (1) W arranty Registration Card HARDW ARE INST ALLA TION GUIDE 1.
UP625/ UP825 Guaranteed Uninterruptible Power System ◆ Power Button Press the power button to turn the UPS ON or OFF ◆ Power On Indicator This LED is illuminated when the utility condition is normal and the U PS outlets are providing “clean power”, free of surges and spikes.
BA TTERY REPLACEMENT AND STORAGE Contact your dealer or call the number in this manual for information on batte ry replacement. The order numbers for the bat tery are as follows: BA -UP 625 for UP625 BA -UP 825 for UP825 CA UTIO N! Read and follow the IMPORT ANT SAFETY INSTRUCT IONS before servicing the battery .
UP625/ UP825 Guaranteed Uninterruptible Power System 5. Remove the battery from the compartment. 6. Disconnect the battery wires from the battery . 7. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting the black wire to the negative (-) terminal of the batter y .
TROUBLESHOOTING Problem Possible Cause Solution Batteries are not fully charged. Recharge the batte ry by leaving the UPS plugged in. The UPS does not perform expected runtime. Battery’ s capacity diminishes over tim e and use. Contact CyberPower Sy stems at tech@cyberpow ersystems.
UP625/ UP825 Guaranteed Uninterruptible Power System TECHNICAL SPECIFICA TIONS Model UP625 UP825 Capacity (V A) 625V A 825V A Capacity ( Watt s) 340W 450W Input Input V oltage Range 100V ac – 140V a.
DEFINITIONS FOR ILLUMINA TED LED INDICA TORS Power On Wiring Fault Using Battery Circuit Breaker Ala r m Condition On Of f Off Set Off Normal Off On/Of f On Set Tw o Beeps Utility Failure- The UPS is providing batter y po wer to the Battery-Power Supplied outlets.
UP625/ UP825 Guaranteed Uninterruptible Power System below . Additionally , S tate or Provincial law ma y adjust the terms of the Limited W arranty or the Power Control Guarantee or the S t ate or Province may impose addi tional obligations, or additional "implied warranties.
9 CyberPower will inspect and examine the Product within ten (10) days of receipt. If the Product is not as warranted, CyberPower will re pair or replace the Product and retu rn it to you at CyberPowe.
UP625/ UP825 Guaranteed Uninterruptible Power System end-user consumer purchaser of the product. 2. Call CyberPower at (952) 403-9500, write to C yberPower at 5555 12th Ave East, Suite 1 10, Shakopee, MN 55379, or e-m ail CyberPower at tech@cyberpowersystems.
11 Any Implied W arranty of Merchantability or for Fitn ess for a Particular Purpose, if appl icable to the Product, is limited in duration to the pe riod of o wnership by the Initial Custome r .
UP625/ UP825 Guaranteed Uninterruptible Power System 12 Exclusion of Consequential an d Other Damages . The sole and exclusive remedies of the Initia l Cus tomer are those provided by the Limited W arranty and Power Control Guarantee. C yberPower excludes any liability for personal injury under the Limited W arranty and Power Control Guarantee.
13.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il CyberPower Systems UP625 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del CyberPower Systems UP625 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso CyberPower Systems UP625 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul CyberPower Systems UP625 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il CyberPower Systems UP625, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del CyberPower Systems UP625.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il CyberPower Systems UP625. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo CyberPower Systems UP625 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.