Manuale d’uso / di manutenzione del prodotto Sulfur-Cleer del fabbricante Culligan
Vai alla pagina of 27
Culligan ® Sulfur-Cleer ™ Automatic Water Filter Owners Guide.
Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations.
Table of Contents iii S p e c i fi c a t i o n s ................................................1 I n t r o d u c t i o n ..................................................2 O p e r a t i n g C o n d i t i o n s .....................................
This page intentionally left blank. iv.
Specifications Culligan ® 10” Sulfur-Cleer ™ Filter with Fiberglass Tank Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1” 5-cycle reinforced thermoplastic T i m e r .....................................
Introduction Operation Step 1. Service Cycle In the service cycle, raw water enters the inlet port of the media tank. The oxidation process begins. This air/water contact oxidizes the iron and hydrogen sulfide in the water. Oxidized iron particles are trapped by the filter bed as the water passes through.
Step 3. Filter Tank Operation - Backwash Cycle Reversing the flow of water through the filter bed and backwashing dirty water to the drain cleans the filter bed.
The concentration limits listed below reflect the minimum or maximum individual limit that each contaminant was tested for separately without any interference of other contaminants in the influent water.
Fam ilia riz atio n Power Loss The Circuit b oard is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost.
Modes of Operation Manual Regeneration Pressing and holding the regen button for 5 seconds will initiate an immediate regeneration. The beeper is to give one beep at the start of manual regeneration (when the motor starts to turn).
7 The circuit board controls all of the filter functions. These settings are programmed at the time of installation. The following is a list of all the microprocessor functions, in the event that any of the settings need to be adjusted. Display Icons The display is to be backlit and have the icons as shown.
8 • Time of Regeneration - This setting is used to program the time at which a regeneration is to occur in the delay mode. The display will first show “tor” for two seconds. After “tor” is shown the display will then show the default of 2:00 AM (or the current programmed time of regeneration if already set).
9 If any of the days were set to “yes”, the display will show “SETDAY” followed by “SUN”. This selects the current day of the week. The “+” or “-“ key toggles through the days of the week and pressing the “STATUS” key saves the setting and advances to the next programming step.
Programming (cont.) • Filter Media Life - This setting is available only with flow meter attached. It enables or disables an alert code ( CHANGE MEDIA ) that indicates the end of life for the filter media.
Programming (cont.) • Auxiliary Output #1 “ON” Time - This setting is used to control the “ON” time of the aux1 output which turns on the compressor and vent solenoid. The aux 1 output should act independently, however, it should never be activated during a regeneration.
12 The statistical functions are reached by pressing the “Information” key. Repetitive presses of the “Statistics” key will cycle through the standard statistics mode until cycled back to time of day display.
When and How to Bypass Your Water Conditioner 13 Normally, all water except outside lines passes through the water conditioner. There are times when the water conditioner should be bypassed, using the push-button Cul-Flo-Valv ® Bypass, or a 3-way bypass valve.
Regeneration with Bleach When bleach is used to regenerate the Sulfur-Cleer ™ , Culligan strongly recommends the dealer set-up a service contract with the customer to initiate the regeneration when required.
15 Things to Check Before You Call for Service If you unexpectedly experience problem water, make these simple checks before calling your Culligan dealer.
16 Preventative Maintenance The Culligan Sulfur-Cleer ™ water filter has been designed to provide a good, consistent service life. Because of the nature of problem water, we recommend that the local Culligan dealer provide regular maintenance/service contracts for the proper operation of your systems.
17 Troubleshooting Guide Complaint Problem Cause Solution Iron bleed- through or staining. A. Inadequate backwash of filter 1. Plugged drain line flow control 1. Call your Culligan dealer for service. 2. Insufficient water supply from well. 2. Check for minimum specified flow and pressure requirements of filter system.
Troubleshooting Guide (cont.) 18 Complaint Problem Cause Solution Water leaking from relief valve. A. Dirt lodged under seat of valve. 1. Pressure has exceeded rating on relief valve and caused valve to open 1. Call your Culligan dealer for service. B.
19 Troubleshooting Guide (cont.) Complaint Problem Cause Solution Water is running to drain continuously. A. Control valve is stuck in regeneration cycle. 1. Electrical service to control(s) has been interrupted. 1. Assure continuous electrical service is available.
20 Performance Data Sheet Culligan ® Sulfur-Cleer ™ Water Filter Important Notice — Read this data sheet and compare the capabilities of the unit to your actual water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing a water treatment unit.
21 Records and Data Important Data on Your Water Filter It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer.
Culligan Limited Warranty 22 Culligan ® Sulfur-Cleer ™ Automatic Water Filters You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan In.
23 You Get Your Water Expert, The Culligan Man ® We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over seventy years, delivering dependable service all along.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Culligan Sulfur-Cleer è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Culligan Sulfur-Cleer - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Culligan Sulfur-Cleer imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Culligan Sulfur-Cleer ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Culligan Sulfur-Cleer, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Culligan Sulfur-Cleer.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Culligan Sulfur-Cleer. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Culligan Sulfur-Cleer insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.