MO-453 ECN 4809-MA MADE IN USA ECM OPERATION MANUAL Model: CSHB60-90XE c WARNING: • Do NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
All installations and services must be performed by qualifie d service personnel. i INDEX SECTION B E G I N N I N G P A G E I. BLOWER CONTROLLER INFORMATION 1 A. TERMINAL DEFINITIONS & FIELD WIRING 1 B. WIRING & SW ITCHES 2 C . I N P U T S 3 D .
All installations and services must be performed by qualifie d service personnel. 1 I. BLOWER CONTROLLER INFORMATION A. TERMINAL DEFINITIONS & FIELD WIRING Burner Harness Connector P1 Pin 1 – Limi t switch connection. Pin 2 – 120 VAC Line connection.
All installations and services must be performed by qualifie d service personnel. 2 B. WIRING & SWITCHES : TURN OFF THE ELECTRICAL POWER to the furna ce before attempting to disconnect blower wiring.
All installations and services must be performed by qualifie d service personnel. 3 C. Inputs Power supplies Line voltage is appli ed between the "S1" and "N1" quick connect term inals. 24 VAC Class II Transform er secondary voltage suppli ed to X and C Limit Switch The 120VAC lim it switch is connect ed to pins P2-1 & 9.
All installations and services must be performed by qualifie d service personnel. 4 EAC (electronic air cleaner) The control provides a 120VAC output for an el ectronic ai r Cleaner. This output is en ergized whenever the fan motor is energized (either low, heat or cool speed).
All installations and services must be performed by qualifie d service personnel. 5 Heat Mode When a call for heat ("W") is received from the thermostat , if the “Cool” mode is not already active, the “T-T” terminal is energized and the blower on delay is started.
All installations and services must be performed by qualifie d service personnel. 6 F. CFM TABLES The following tables contai n blower speed settings and thei r respective air flowrates for the EC M blower motor.
All installations and services must be performed by qualifie d service personnel. 7 II. ECM TROUBLE SHOOTING A. DIAGNOSTC FEATURES The control board is equipped wit h 4 green Input Status LEDs and 1 red Board Status LED. These are i ntended to provide a quick view into furnace pe rformance without requiring a voltm eter.
All installations and services must be performed by qualifie d service personnel. 8 • Verify fan is not in delay mode – wait un til delay complete • “R” missing/not connected at m otor • S.
All installations and services must be performed by qualifie d service personnel. 9 • Check and plug leaks in return ducts, cabinet Comfort Check • Check proper airflow settings • Low static pre.
All installations and services must be performed by qualifie d service personnel. 10 CONFI RM IF EI THER BLOWER W HEEL IS RU BBING AG AINST HOUSING OR M OTOR SHAFT IS SPINNI NG FR EELY, REPAIR OR REPLACE AS N ECESSARY.
All installations and services must be performed by qualifie d service personnel. 11 BLOWER Off- Delay Active? Se q uence of O p eration BURNER On 1. A/C Off 2. COOL mode Off 3.BLOWER Off-Delay Started 4. Status LED Off BLOWER = LOW BLOWER = COOL COOL Mode On? Y Active? On-Delay Ended? Yes Ye s Yes Yes No No No No DEHUM Active? BLOWER = LOW 1.
All installations and services must be performed by qualifie d service personnel. 12 Sequence of Operation Glossary Inputs: LIMIT - 120vac power from the High Li mit Swi tch used to power the burner. W- Switched 24vac indicating a Heat call from the thermostat.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Crown CSHB60-90XE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Crown CSHB60-90XE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Crown CSHB60-90XE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Crown CSHB60-90XE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Crown CSHB60-90XE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Crown CSHB60-90XE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Crown CSHB60-90XE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Crown CSHB60-90XE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.