Manuale d’uso / di manutenzione del prodotto 32-380ECS del fabbricante Crown Boiler
Vai alla pagina of 16
D e s i g n e D t o L e a D T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
.
I Pr oduct Description This supplement covers information not included in the standard Series 32 installation manual that is unique to the following models: 32-380WNLECS, 32-475WNLECS 32-380WNTECS, 32-475WNTECS 32-380SNLECS, 32-475SNLECS Follow the Series 32 installation instructions except where noted in this supplement.
VII V enting Refer to installation manual. V ent sizing for the 32-380ECS should always be done in accordance with the National Fuel Gas Code. A vent damper can be installed on any 32-380ECS or 32-475ECS equipped with a 24 volt control system except for those with tankless heaters.
W ARNING All wiring and grounding must be done in accordance with the authority having jurisdiction or , in the absence of such CAUTION Make sure that damper and BVS harnesses are secured so that they do not come in contact with draft hood or steam piping.
“BURNER” “BURNER” TH TR + ROBERTSHAW 7000DERHC GAS V AL VE VENT DAMPE R (NOTE 2) NOTE 2 LESS VENT DAMPER 2. ON BOILERS LESS VENT DAMPER, DAMPER HARNESS NOT USED. RED AND BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE. RD RD RD ALARM ALARM 2 (NOTE 2) 2.
Sequence of Operation - Steam Boiler 1) When the boiler is ener gized, 24 volts is immediately applied to terminals “1” (blue) and “4” (yellow) on the vent damp - er . Assuming that there is no call for heat, and that the damper switch is in the “automatic” position, the damper will close.
2 HIGH LIMIT LOW LIMIT HONEYWELL L8124E TH TR + ROBERTSHAW 7000DERHC GAS VAL VE PILOT VAL VE MAIN VAL VE RD RD RD/YE RD RD/YE ALARM ALARM Figure C: W ater Boiler Wiring (W ith T ankless Heater) Figure.
equipped with a reset button which must be pressed to restore normal burner operation. An open blocked vent switch is indicative of a problem with the vent system. If the blocked vent switch opens, the cause of the venting problem must be found and corrected by a qualied gas service technician before the blocked vent switch is reset.
Figure F: W ater Boiler Contr ol Installation (Less T ankless Heater V ersion Shown) Figure E: Blocked V ent Switch Installation 8.
6) Once the ignition module detects the presence of a pilot ame, voltage is applied across the main valve (terminals “MV” and “MV/PV”), opening the valve and establishing main ame.
380 475 380 475 I A PART # (STANDARD) 310000 310001 310002 3110053 3110063 310405 310406 311026 311020 311010 310400 311027 311028 311031 1 EA. 1 EA. BOILER MODEL 32-380ECS 1 1 3 1 1 1 1 1 1 1 1 31103.
BASE SIDE CAR TON - See Installation Manual JACKET SIDE P ANEL CAR TON- See Installation Manual W A TER AND STEAM BOILER CAR TONS - As shown in Installation Manual except that Rating Plate is factory applied to RH Side Jacket Panel.
12 STEAM PROBE CONTROL SUB ASSY 3513210 1 LWCO, CG400 WITH "P" PROBE 400824 1 BLOCKED VENT SWITCH ASSY 960128 1 GLASS SET (20-104-10, 8" CTR TO CTR) 950080 1 L404F PRESSURE LIMIT 350380.
.
PN 980895 05/10 T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Crown Boiler 32-380ECS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Crown Boiler 32-380ECS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Crown Boiler 32-380ECS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Crown Boiler 32-380ECS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Crown Boiler 32-380ECS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Crown Boiler 32-380ECS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Crown Boiler 32-380ECS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Crown Boiler 32-380ECS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.