87130A Attenuator/Switch Driver Operating and Service Guide Manual par t number: 87 130-90007 Printed in USA August 2001 Supersede s: May 2000.
ii Agilent 87130A Operating and Service Manual Notice The infor mation containe d in this document is subject t o change wit hout notice. Agilent T echnologi es makes no warranty o f any kind with regard t o this materia l, including, but not li mited to, the implied war ranties of merchanta bility and fitness for a part icular pur pose.
Agilent 87130A Operating and Service Manual iii Wa r r a n t y Certific atio n Agilent T echnolog ies, Inc., certifies that thi s pr oduct met its p ublished spec ific atio ns a t the time of sh ipme nt from the fac tory .
iv Agilent 87130A Operating and Service Manual W ARRANTIES OR MERCHANT ABILITY AND FITNESS FOR A P AR TICULAR PURPOSE. EXCLUSIVE REMEDIES. THE REMEDIES PROVIDED HEREIN ARE BUYER ’ S SOLE AND EXCLUSIVE REMEDIES.
Agilent 87130A Operating and Service Manual v Service and Support Any adjust ment, mainte nance, or repa ir of th is product must be perfo rmed by quali fied pers onnel. Cont act your c ustomer engi neer thr ough your loca l Agilent T echnologi es Servi ce Center .
vi Agilent 87130A Operating and Service Manual Safety and Regulatory Infor mation Review this prod uct and re lated docu mentation to famili arize you rself wit h safety markings and inst ructions bef ore you ope rate the instrument. Thi s product has been des igned and t ested in accordanc e with int ernational standar ds.
Agilent 87130A Operating and Service Manual vii Safety Earth Ground This is a Safety Class I prod uct (prov ided with a pr otective earthing terminal ). An uninter ruptibl e safety ea rth ground must be provided fro m the main power s ource to the product input wiri ng terminal s, power cord, o r supplie d power cord set.
viii Agilent 87130A Operating and Service Manual General Safety Consi derations W ARNING • This product has b een designed and te sted in accordance with IEC Publication 1010, Safety Requireme nts for Electronic Meas uring Apparatus, and has been supplied in a safe condition.
Agilent 87130A Operating and Service Manual ix.
x Agilent 87130A Operating and Service Manual T ypeface C onventions Itali cs • Used to emphasi ze importa nt infor mation: Use this software onl y with the 87130A. • Used for t he titl e of a publ ication : Refe r to t he Agilent 8713 0A Operating and Servic e Manual .
Contents Agilent 87130A Operating and Service Manual Contents-1 1. Introducing t he 87130A Atte nua tor /Sw itch Dr ive r Feature s of the Attenuat or/Switch Driver . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Figur e 1-1. 87130A Block Diagram .
Contents-2 Agilent 87130A Operating and Service Manual Figur e 2-7. Daisy Chain of Driver Ca r ds in Si ngle Enclo sur e . . . . 2-8 Figur e 2-8. Daisy Chain of Driver Ca r ds in Dif fer ent Enclosur es . 2-8 Connecting At tenuators . . . . . . . . . .
Agilent 87130A Operating and Service Manual Contents-3 *IDN (Identi fication Number) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 *OPC (Operation Compl ete) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- 17 *RST (Reset ) .
Contents-4 Agilent 87130A Operating and Service Manual Figur e 4-1. T iming Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-77 5. Replaceable Pa rts Accessory Boar ds and Cables . . . . . . . . . . . . . . . . . . . . . . . . .
Agilent 87130A Operating and Service Manual 1-1 1 Intr oducing the 87130A Attenuator/Switch Driver Overview I n this cha pter you wi ll find: • Function , feature s, and capabil ities of t he 87130A.
1-2 Agilent 87130A Operating and Service Manual Introducing the 87130A Attenuator/Switch Driver Features of th e Attenuator/Switch Driver Features of the Attenuator/Swit ch Drive r The Agilen t 87130A att enuator/swi tch drive r is a GPIB compat ible instru ment design ed to driv e electr omechanical switches and step attenua tors.
Agilent 87130A Operating and Service Manual 1-3 Introducing the 87130A Attenuator/Switch Driver Features of t he Attenuator/Switch Driver Drive Puls e and Sensing The atte nuator/s witch dri ver can d.
1-4 Agilent 87130A Operating and Service Manual Introducing the 87130A Attenuator/Switch Driver Features of th e Attenuator/Switch Driver Compa tible S witch es and Attenuators The atte nuator/ s witch dri ver is de signed to drive Agil ent switches and attenua tors shown in the ta bles belo w .
Agilent 87130A Operating and Service Manual 1-5 Introducing the 87130A Attenuator/Switch Driver Features of t he Attenuator/Switch Driver Front Panel Featur es The front panel LEDs i ndicate the status o f the 87130 A atten uator/switc h driver .
1-6 Agilent 87130A Operating and Service Manual Introducing the 87130A Attenuator/Switch Driver Unpacking Your Instru ment Unpacking Y our Instrument Unpack and i nspect t he shippi ng contain er and it s contents thoroughl y to ensure t hat nothing was damaged duri ng shipment.
Agilent 87130A Operating and Service Manual 1-7 Introducing the 87130A Attenuator/Switch Driver Unpacking Your Inst rument Figure 1-3 Packaging Mat erials for the 87130A Sw itch Driver Item Quantity Part Number Description 1 1 921 1- 6365 Outer carton 2 1 5181-5515 Foam In sert 3 Foam insert (Part of item 2.
1-8 Agilent 87130A Operating and Service Manual Introducing the 87130A Attenuator/Switch Driver Before Installing th e Attenuator/Switch Driver Befor e Installing the At tenuator/Switch Driver Electr ostatic dischar ge ( ESD) can d amage or d estroy e lectron ic componen ts.
Agilent 87130A Operating and Service Manual 1-9 Introducing the 87130A Attenuator/Switch Driver Before Installing t he Attenuator/Switch Driver Reducing ES D Damage T o help reduce the amount of ESD d.
1-10 Agilent 87130A Operating and Service Manual Introducing the 87130A Attenuator/Switch Driver Returning Your Instrum ent for Service Returning Y our Instrument for Service T o obtain serv icing inf.
Agilent 87130A Operating and Service Manual 2-1 Installing the 87130A Attenuator/Switch Driver 2 Installing the 87130A Attenuator/Switch Driver Overview I n this cha pter you wi ll lear n about: • H.
2-2 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Getting Start ed Gettin g Started Initi al Insp ecti on 1. Unpack and inspect the sh ipping cont ainer and it s content s thorough ly to ensure t hat nothing wa s damaged dur ing shipmen t.
Agilent 87130A Operating and Service Manual 2-3 Installing the 87130A Attenuator/Switch Driver Getting Started GPIB Addr essing 3. Use the f ive-bit binary add ress swit ches loca ted on the rear pane l of the instru ment to c hange the GPIB address. ❍ The 87130A has a factor y preset a ddress of 9.
2-4 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s Connecting Switc h Drivers to Swit ches and Attenuators Driver Boar ds The stand ard 87130A at tenuator /switch d river has a single interna l driver board capable of driv ing 31 switche s.
Agilent 87130A Operating and Service Manual 2-5 Installing the 87130A Attenuator/Switch Driver Connecting Switch Drivers to Switches and Attenuato rs Using External Drivers A standard switc h driver can contr ol up to se ven extern al 84940A drive r car ds.
2-6 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s CAUTION Do not c onnect or disconn ect rel ays from 84940A ext ernal driv er ca rds with prefix es prior to US4016 whil e the attenu ator/swi tch drive r line switc h is turned o n.
Agilent 87130A Operating and Service Manual 2-7 Installing the 87130A Attenuator/Switch Driver Connecting Switch Drivers to Switches and Attenuato rs W iring Channel Connector s When ins talling th e switch dr iver , it is impe rative t o know which wi res will cause an OPEN or CLOSE cond ition on e ach switch.
2-8 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s Connecting Multiple Driver Cards The cards are numb ered from 1 to 8 ; the rel ays on eac h card are numbered from 0 to 30.
Agilent 87130A Operating and Service Manual 2-9 Installing the 87130A Attenuator/Switch Driver Connecting Switch Drivers to Switches and Attenuato rs Connecting Attenuators Connect a ttenuat or cable s using a V iking connector and a t en pin c onnector .
2-10 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s Optimizing S witching Speed T o increase th e sp.
Agilent 87130A Operating and Service Manual 2-11 Installing the 87130A Attenuator/Switch Driver Connecting Switch Drivers to Switches and Attenuato rs Driver Car d Address Set the 4- bit DIP switc h on the 84940A dri ver assembly ca rd to each add ress as sho wn in the figur e be low .
2-12 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s 7061 1-6001 1, and 70612-6001 1 cables o f #28 A WG wire size , at a tot al cable le ngth of 32.8 fee t from the 87130 A would have a volta ge of 20.
Agilent 87130A Operating and Service Manual 2-13 Installing the 87130A Attenuator/Switch Driver Connecting Switch Drivers to Switches and Attenuato rs Pin Functions for 36-Pin I/O Data Cable • The stand ard switc h driver has a high densi ty male, 36-pi n SCSI II t ype connecto r .
2-14 Agilent 87130A Operating and Service Manual Installing the 87130A Attenuator/Switch Driver Connecting Switch Dr ivers to Switches and Attenuator s Pin Function s for 68-pin Driver Output Connector • The 87130A ha s a rear -panel 68-pin c onnector for drivi ng attac hed switches .
Agilent 87130A Operating and Service Manual 3-1 3 Specifica tions Overview Pe rformance specific ations a re the per formance s tandards o r limits aga inst which the 87130A can be tested.
3-2 Agilent 87130A Operating and Service Manual Specifications Performance Specif ications Performance Spe cifications T able 3-1 87130A Elec trical Sp ecificati ons 1. Refer to “ Compatible Switches and Attenua tors ” on page 1- 4 if you are usi ng switches or attenuators ma de by another c ompany .
Agilent 87130A Operating and Service Manual 3-3 Specifications Performance Specificatio ns T able 3-2 87130A Envir onmental Spec ifications Environmental Speci fications T empe rature Operating 0 to +.
3-4 Agilent 87130A Operating and Service Manual Specifications Performance Specif ications.
Agilent 87130A Operating and Service Manual 4-1 4 Remote Operation Overview I n this cha pter you wi ll lear n about pro gramming the 87130A using a control ler: • How to set up t he switch drive r .
4-2 Agilent 87130A Operating and Service Manual Remote Operation Progr ammi ng Pr ogramming Sta nda rd C omm a nds The instrumen t command lang uage is Standa rd Commands for Programmabl e Instru ments (SCPI) . The progr amming examples and infor mation in t his chapt er use the SCPI format.
Agilent 87130A Operating and Service Manual 4-3 Remote Operation Progra mming Syn tax Pr ogramming Syntax T alking to the Switch Driver In gener al, computer s acting as controll ers communic ate with.
4-4 Agilent 87130A Operating and Service Manual Remote Operation Programm ing Syntax Addr essing the Swit ch Driver Since GPIB c an address multiple dev ices thr ough the sa me interf ace card, the devi ce selec tor passe d with the prog ram messa ge must include not only the corr ect int erface c ode, but al so the correc t instr ument addre ss.
Agilent 87130A Operating and Service Manual 4-5 Remote Operation Progra mming Syn tax Commands A command is compose d of a head er , any a ssociated da ta, and a t erminator . The header is the mnemonic or mnemoni cs that repre sent the oper ation to be perfor med by the s witch driver .
4-6 Agilent 87130A Operating and Service Manual Remote Operation Programm ing Syntax Example *CLS is an example of a common command he ader . *CLS; ROUTE:DRIVE:ON (@100,102,104,106,....); Common commands use d by the swi tch driver a re explaine d in more det ail in the “ Common Command Referen ce ” later i n this ch apter .
Agilent 87130A Operating and Service Manual 4-7 Remote Operation Progra mming Syn tax Character Program Data Characte r program data is used to convey par ameter infor mation as alph a or alphanumer ic stri ngs. Example ROUTE:VERIFY:ON:ALL The :VERIFY func tion is s pecifie d to be ON fo r ALL cha nne ls.
4-8 Agilent 87130A Operating and Service Manual Remote Operation Programm ing Syntax Query commands are also used to get r esults of switch s tatus made by t he switc h d river, with the qu ery ac tua lly a ctiva ting the switc h.
Agilent 87130A Operating and Service Manual 4-9 Remote Operation Programming th e Switch Driver Pr ogramming the Swi tch Driver Initi alizat ion T o make sure the bus and all appropri ate inte rfaces a re in a kno wn state, begin e ver y pr ogr am with a n i nit ializa tio n s tate men t.
4-10 Agilent 87130A Operating and Service Manual Remote Operation Programming th e Switch Driver wher e GROU P1 represent s the name of th e desired gr oup.
Agilent 87130A Operating and Service Manual 4-11 Remote Operation Programming th e Switch Driver Stri ng V a riab les If you wan t to obser ve the header s for quer ies, you must bring the r eturned data in to a BASIC str ing variabl e.
4-12 Agilent 87130A Operating and Service Manual Remote Operation Common Com mands Reference Common Commands Refer en ce The common commands us ed in this i nstrument a re shown in the fo llowing table .
Agilent 87130A Operating and Service Manual 4-13 Remote Operation *CLS (Clear Status) *CLS (C lear Status) Synta x *CLS Description The *CLS (cl ear stat us) common command clears t he statu s data st ructures, includi ng the device defined e rror queu e.
4-14 Agilent 87130A Operating and Service Manual Remote Operation *ESE (Event Status Enable) *ESE (Event Status Enable) Synta x *ESE mask *ESE? Description The *ESE command sets the Standa rd Event St atus Enable Reg ister bi ts. This regist er contains a mask value for the b its to be ena bled in t he Standard Event Sta tus Register .
Agilent 87130A Operating and Service Manual 4-15 Remote Operation *ESR? (Event Status Regist er Query) *ESR? (Event S tatus Registe r Query) Synta x * ESR? Description The *ESR qu ery returns the conte nts of th e Standard Event Stat us Registe r . The tabl e shows each bit in th e Event Sta tus Regist er and th e bit weigh t.
4-16 Agilent 87130A Operating and Service Manual Remote Operation *IDN (Identificat ion Number) *IDN (Ide ntification Number) Synta x * IDN? Description The *IDN qu ery allo ws the inst rument to identify itself .
Agilent 87130A Operating and Service Manual 4-17 Remote Operation *OPC (Ope ration Comple te) *OPC (O perat ion Com plete) Synta x *OPC *OPC? Description The *OPC and *OPC? commands are used to synchro nize remot e interface softwar e to inte rnal module events.
4-18 Agilent 87130A Operating and Service Manual Remote Operation *RST (Reset) *RST (R eset) Synta x *RST Description *RST is equi valent t o a power up c ondition for the swit ch hardware . All rel ays for which DRI VE is ON are s et to the position s determin ed by ROUTe:PFAil.
Agilent 87130A Operating and Service Manual 4-19 Remote Operation *SRE (Request Enable) *SRE (R equest E nable) Synta x *SRE mask *SRE? Description The *SR E command sets the Service Request Enable Registe r bits. This wil l indicat e whether or not the device ha s at leas t one reas on for re questing servic e.
4-20 Agilent 87130A Operating and Service Manual Remote Operation *STB (Statu s Byte) *STB (Sta tus Byt e) Synta x *STB? Description The *STB qu ery retu rns the cu rrent val ue of the instrument ’ s status byt e. Refer to the tabl e below for the de finitions of the bit s in the status by te.
Agilent 87130A Operating and Service Manual 4-21 Remote Operation *TST? (Te st) *TST? (T est) Synta x *TST? Description *TST? causes al l relays to cycle through bot h of thei r positions (first all the CLOSE paths a re set; the n all the OPEN paths), a nd then get placed in th e approp riate p ower up posi tions.
4-22 Agilent 87130A Operating and Service Manual Remote Operation *WAI *W AI Synta x *WAI Description The *WAI comman d ca use s the i nst rume nt to wa it for a ll pe nd ing G PIB operati ons to fi nish befo re pro cessing an y further co mmands.
Agilent 87130A Operating and Service Manual 4-23 Remote Operation Hierarchy Hierar chy T able 4-6 Command T ree ROUTE :CLOSe :OPEN :PATH :DEFine :CATalog :LABel :VALue :DELete :ALL :GROUP :NAME :CATal.
4-24 Agilent 87130A Operating and Service Manual Remote Operation Hierarchy T able 6-6. Command T r ee (conti nued ) ROUTE :PFAil :CLOSe :OPEN :DELete :VERify :ON :OFF :ALL :DRIVe :ON :OFF :ALL :WIDth.
Agilent 87130A Operating and Service Manual 4-25 Remote Operation Hierarchy T able 6-6. Command T r ee (conti nued) NOTE A colon ( : ) must be u sed in front of the ROUTE , DIAGnostics , MEMory , etc. commands if that command is not the fi rst it em in a com mand string .
4-26 Agilent 87130A Operating and Service Manual Remote Operation SCPI C omm and Re fer ence SCPI Command Refer ence Channel List s The 87130A can co ntrol up to s even dif f erent e xternal driver ca rds, each o f which can drive up t o 31 dif ferent relays.
Agilent 87130A Operating and Service Manual 4-27 Remote Operation :ADD :ADD Synta x ROUTE:GROUP:ADD <group name>,<path name > Description This command adds an exist ing path to t he end of an existing gr oup. The group name a nd path name must have bee n previously defined us ing GROUP:NAME and PATH:DEF.
4-28 Agilent 87130A Operating and Service Manual Remote Operation :AUTOselect :AUTOselect Synta x ROUTe:GROUP:AUTOselect[?] < group name > Description This tur ns the cur rent Auto Select st ate for the group o n or of f. Example Command ROUTE:GROUP:AUTO:ON ATTEN; This turns the current Auto Select state for the group ATTEN on.
Agilent 87130A Operating and Service Manual 4-29 Remote Operation :CAT al og? :CA T alog? Synta x ROUTe :CATALOG? Description Returns a list of groups (u p to 16) or all defined paths in t he module. Example Query ROUTE:GROUP:CATALOG? This quer y returns a list of a ll of th e group names , in order from 1 to 16, separat ed by commas.
4-30 Agilent 87130A Operating and Service Manual Remote Operation :CLOSe :CLOSe Synta x ROUTe:CLOSe ROUTe:PFail:CLOSe[?] Description Each chann el has a CLOSE o r OPEN position. On Agilent r elays, the CLOSE path is the pa th between the input terminal labeled 2 on the rel ay and the input terminal labele d C.
Agilent 87130A Operating and Service Manual 4-31 Remote Operation :CLOSe Example Command ROUTE:CLOSE ATTEN_14; Sending t he above comman d causes the s et of swit ch OPENs and CLOSEs defined by the PATH (r efer to :P A TH on page 4-55 ) with name ATTEN_14 to be execut ed.
4-32 Agilent 87130A Operating and Service Manual Remote Operation :CLOSe Example Query ROUTE:PFAIL:CLOSE? (@1 01,205); The incl usion of a question ma rk causes a readback of the power up state of the requ ested cha nnels as a li st of 1 ’ s and 0 ’ s separated by co mmas.
Agilent 87130A Operating and Service Manual 4-33 Remote Operation :CYCLes? :CYCLes? Synta x DIAGnostics:EERom:CYCLes? Description This query ca uses the 87130A to rea d back the number of ti mes to which the EEROM has been wr itten. If t his number e xceeds 10,000 t he EEROM should be replaced .
4-34 Agilent 87130A Operating and Service Manual Remote Operation :DEFine :DEFine Synta x ROUTe:PATH:DEFine <path name>,<channel list> [,<channel list>] ROUTe:GROUP:DEFine? <group.
Agilent 87130A Operating and Service Manual 4-35 Remote Operation :DEFine Example Command ROUTE:PATH:DEF ATTEN_14,(@101,2(0:5)),( @102); This command defines a pat h whose name i s ATTEN_14 whose first channel list a ffe cts channe l 1 on card 1 a nd channels 0 through 5 on card 2, a nd whose seco nd chann el list affect s channel 2 on card 1 .
4-36 Agilent 87130A Operating and Service Manual Remote Operation :DELay :DELay Synta x ROUTe:DELay:<delay time>, Description This comman ds sets the d elay time in sec onds require d to val idate t he sense lines on a relay f or which sen sing will be used.
Agilent 87130A Operating and Service Manual 4-37 Remote Operation :DEL ay NOTE The query fo rm is not av ailable when usi ng a path name due to the potent ial for conf usion bet ween the first g roup and th e second in the pa th.
4-38 Agilent 87130A Operating and Service Manual Remote Operation :DELete :DELete Synta x ROUTE : DELete Description This command delet es: • All data associat ed with the specifie d path or group a nd frees up the path stor age r egis ter. • All ch an nels from the PFAIL list .
Agilent 87130A Operating and Service Manual 4-39 Remote Operation :DELete • MEMory:DELete; MEMory:DELete erase s all d ata fr om CM OS R AM, by f illin g it with ze roe s, and th en sets it to an ini ti al st ate. T hat sta te is as fo llo ws: ❍ The p ower fail cha nne l lis ts ar e em pt y ( ROUT:PFA:CLOS and ROUT:PFA:OPEN ).
4-40 Agilent 87130A Operating and Service Manual Remote Operation :DRIVe :DRIV e Synta x ROUTe:DRIVe : ALL ROUTe:DRIVe [?]<channel list> ROUTe:DRIVe : <pathname> Description There is a list of r elays con sidered un used or “ not t here ” by the f irmware.
Agilent 87130A Operating and Service Manual 4-41 Remote Operation :DRIVe Example Query • ROUTE:DRIVE:ON? (@101,103,105); This comman d returns a l ist of 1 ’ s and 0 ’ s, separated by commas, depending on whether drive is on or of f for the indic ated chan nels.
4-42 Agilent 87130A Operating and Service Manual Remote Operation :EERom :EERom Synta x DIAGnostics:EERom:CYCLes? Description This func tion allows EERom informati on to be read out.
Agilent 87130A Operating and Service Manual 4-43 Remote Operation :ERRor? :ERRor? Synta x SYSTem:ERRor? Description As SC PI sp eci fies , th is r eads o ut th e fu ll er ror numb er a nd e rror d esc ript ion for the first e rror in t he error queue.
4-44 Agilent 87130A Operating and Service Manual Remote Operation :ERRor? -181,Invalid outside macro definition -183,Invalid inside macro definition Execu tio n Errors These set the Exec Err bit in ESR.
Agilent 87130A Operating and Service Manual 4-45 Remote Operation :ERRor? 1004,EEROM data invalid Corrupti on has been detected in the EEROM; i t needs to be replaced, or , if brand new , it nee ds to have ME M:SAVE executed once.
4-46 Agilent 87130A Operating and Service Manual Remote Operation :FREE? :FREE? Synta x MEMory:Free? Description This is a query which retu rns the nu mber of b ytes that remain in RAM for storin g configur ation dat a, followed by the numbe r of bytes in itiall y availa ble.
Agilent 87130A Operating and Service Manual 4-47 Remote Operation :GROUP :GROUP Synta x ROUTE: GROUP: Description The GROUP subsy stem allo ws grouping o f paths t o customize the manual interf ace to th e 87130A. A “ group ” is an ordere d collection of up to 256 pa ths.
4-48 Agilent 87130A Operating and Service Manual Remote Operation :INITialize :INITialize Synta x MEMory:INITialize Description When t his co mm and is issu ed , RA M is ini tial ized acco rding to t he fol lowin g algori thm: 1. RAM is in itialized to the state de scribed i n MEMory:DELete .
Agilent 87130A Operating and Service Manual 4-49 Remote Operation :LAB el [?] :LABel[?] Synta x ROUTe :LABEL “ <label> ” ; Description This command specifie s a label (32 chara cters max) to be used when labeli ng the grou p on manual i nterfac e screens .
4-50 Agilent 87130A Operating and Service Manual Remote Operation MEMory MEMory Synta x MEMory Description The MEMory subs ystem is us ed to delete , initia lize RAM, and sa ve EEROM info rmation t o the co ntrolle r .
Agilent 87130A Operating and Service Manual 4-51 Remote Operation :NAME :NAME Synta x ROUTE:GROUP:NAME <number>,<group name> Description The groups are numbere d from 1 to 16. The y may be named or renamed using th is command. An at tempt to n ame a group us ing a name al ready in use for another gr oup will r esult in an error .
4-52 Agilent 87130A Operating and Service Manual Remote Operation :OPEN :OPEN Synta x ROUTe:OPEN[?] ROUTe:PFail:OPEN[?] Description Each cha nnel has a CLOSE or OPEN p osition. On Agilent r elays, the OPEN path i s th e pa th be twee n th e in put te rmi nal labe led 1 on th e re lay and th e input t erminal label ed C.
Agilent 87130A Operating and Service Manual 4-53 Remote Operation :OPE N It is possi ble to combine OPEN and CLOSE in a singl e command si nce they are both par t of the ROUTe subsys tem. For exampl e: ROUTE:CLOSE (@406:410);OPEN (@202); This command will clos e channels 6 through 1 0 on card 4 a nd open channel 2 on card 2.
4-54 Agilent 87130A Operating and Service Manual Remote Operation :OPEN Example Query ROUTE:PFAil:OPEN? (@10 1,205) ; The incl usion of a question ma rk causes a readback of the power up state of the requ ested cha nnels as a li st of 1s a nd 0s separ ated by commas .
Agilent 87130A Operating and Service Manual 4-55 Remote Operation :PATH :P A TH Synta x ROUTe:PATH Description The PATH subsys tem a llo ws s tori ng of cha nnel l ists to si mp lify re mo te access a nd to cust omize the man ual inte rface to the 8713 0A.
4-56 Agilent 87130A Operating and Service Manual Remote Operation :PFAil :PF Ail Synta x ROUTe:PFAil Description The ROUT e:PF Ail subsyste m of SCPI all ows specif ication of wh ich channels will be c losed on a p ower cycle (or *RST or *TST?) .
Agilent 87130A Operating and Service Manual 4-57 Remote Operation :REM ove :REMove Synta x ROUTe:GROUP:REMove <group name>,<path n ame> Description This comman d removes all i nstances of the specifi ed path from a gro up. The group name a nd path name must have bee n previously defined us ing GROUP:NAME and PATH:DEF.
4-58 Agilent 87130A Operating and Service Manual Remote Operation ROUTe ROUT e Synta x Refe r to t he com man d tre e. Description Relay swi tching and configura tion is acc omplished by the ROUTe comm and tree.
Agilent 87130A Operating and Service Manual 4-59 Remote Operation :SAVE :SA VE Synta x MEMory:SAVE Description This command copies the RAM i mage to the EEROM. Care shoul d be taken to do th is onl y wh en nec essa ry , du e to the lim ited lif e of t he EER OM.
4-60 Agilent 87130A Operating and Service Manual Remote Operation STATus ST A T us Synta x STATus:OPERation STATus:QUEStionable Description The ST A T us subs ystem is full y specif ied by SCPI.
Agilent 87130A Operating and Service Manual 4-61 Remote Operation SYST em SYST em Synta x SYSTEM Description These ar e SYST em commands from the SCPI specific ation.
4-62 Agilent 87130A Operating and Service Manual Remote Operation TRIGger TRIGger Synta x TRIGger:SEQuence:DELay <number> Description This command allows the user to cont rol the 24 V power suppl y recovery time. Inp ut values are limit ed to bet ween 0 and 200 msec (200 msec is the default setting) .
Agilent 87130A Operating and Service Manual 4-63 Remote Operation :VALue :V ALue Synta x ROUTe:PATH:VALUE <path name>,<number>; Description This comman d specif ies a numbe r (int eger in the range – 32768 to 32767) to be used whe n labeli ng the path on manual in terface screens.
4-64 Agilent 87130A Operating and Service Manual Remote Operation :VERify :VERify Synta x ROUTe:VERify ROUTe:VERify [?] Description This command a dds or remove s relays f rom the “ sen se list ” , th e list of relays for wh ich sensi ng is enab led.
Agilent 87130A Operating and Service Manual 4-65 Remote Operation :VERify ROUTE:VERIFY:ON ATTEN_14; This comm an d cau ses t he s et o f swit che s de fined by th e P A TH wi th th e pathname ATTEN_14 to be added to (ON) or removed from (OFF) the "sense list .
4-66 Agilent 87130A Operating and Service Manual Remote Operation :VERsion ? :VERsion? Synta x SYSTem:VERSion? Description This rea ds out the firmwar e datecod e.
Agilent 87130A Operating and Service Manual 4-67 Remote Operation :WIDTh :WIDTh Synta x ROUTe:WIDTh <pulse width> , ROUTe:WIDTh <channel list> Description This command sets the pulse width in sec onds required to cl ose a relay . The pulse wid th may be set in 5 ms inc rements up t o 1275 ms.
4-68 Agilent 87130A Operating and Service Manual Remote Operation Example Prog rams Example Pr ograms The foll owing progr ams writte n in Rocky Mount ain Basic pro vide sa mple programs t hat may be hel pful in progr amming the 871 30A. Save Memory In order to use th e followi ng program, you must first cre ate a fi le named SWDATA .
Agilent 87130A Operating and Service Manual 4-69 Remote Operation Example Programs 280 ENTER @Sw;A$ 290 I=-1 300 WHILE LEN(A$)>0 310 Comma=POS(A$, ” , ” ) 320 IF Comma=0 THEN 330 A$=A$& ”.
4-70 Agilent 87130A Operating and Service Manual Remote Operation Example Prog rams 670 WHILE LEN(A$)>0 680 Comma=POS(A$, ” , ” ) 690 IF Comma=0 THEN 700 A$=A$& ” , ” 710 Comma=LEN(A$) .
Agilent 87130A Operating and Service Manual 4-71 Remote Operation Example Programs Resto r e Mem ory The foll owing progr am can be use d to rest ore the EEROM st ate read o ut by READMEM: 10 ! WRITEMEM program. Takes a file written by READMEM and sends it to the 87130A.
4-72 Agilent 87130A Operating and Service Manual Remote Operation Example Prog rams 330 ENTER @File;Pathnames$(*) 340 FOR I=0 TO 255 ! send path dat a 350 IF Pathnames$(I)<> ”” THEN 360 ENTE.
Agilent 87130A Operating and Service Manual 4-73 Remote Operation Example Programs 650 END 660 SUB Getandsend_bmap(B$) 670 ! Loads a query response from file and outputs it as a channel list 680 COM @.
4-74 Agilent 87130A Operating and Service Manual Remote Operation Example Speed Calculation Example Speed Calculation Switchin g speed is a functi on of puls e widths, s ensing del ays, the s tate of the chosen c hannels, the seque nce of r elays dr iven and the power suply re covery time.
Agilent 87130A Operating and Service Manual 4-75 Remote Operation Example Speed Calculation 60 ! a range. 70 OUTPUT 709; ” ROUT:DRIV:OFF (@112:130) ; ” 80 ! 90 ! Drive is set to OFF for remaining channels on driver 100 ! card 1.Unless channels are part of Drive list , no 110 ! pulse (:WIDTh) is sent.
4-76 Agilent 87130A Operating and Service Manual Remote Operation Example Speed Calculation 380 OUTPUT 709; ” ROUT:WIDT .04,(@100,10 2,104,108); ” 390 ! 400 ! Pulse (:WIDTh) is set to 40 ms for channels 100,102, 410 ! 104, and 108. When :OPEN is sent, 100 and 10 2 420 ! will OPEN at the same time.
Agilent 87130A Operating and Service Manual 4-77 Remote Operation Example Speed Calculation 780 ! See timing chart to predict when each relay will 790 ! open.
4-78 Agilent 87130A Operating and Service Manual Remote Operation Example Speed Calculation.
Agilent 87130A Operating and Service Manual 5-1 5 Replaceable Par ts Overview I n this cha pter you wi ll find: • Accessor ies avail able for the swit ch driver by part numbe r and descri ption. • All repl aceable parts re ferenced i n chassi s and cable assemblie s.
5-2 Agilent 87130A Operating and Service Manual Replaceable Parts This page int enti onally l eft blank.
Agilent 87130A Operating and Service Manual 5-3 Replaceable Parts Accessory Boards and Cables Addition al driver boards, i nterconne ct boards, and cable s provide expanded capacit y , remote swit ching and ev erything needed for dev ice connec tion.
5-4 Agilent 87130A Operating and Service Manual Replaceable Parts T able 5-2 Replaceab le Parts - 87130A Chassi s Assembly ( 1) Part Location Part Number Quantity Descriptio n Reference Designator 1 8.
Agilent 87130A Operating and Service Manual 5-5 Replaceable Parts Figure 5-1 87130A Chassi s Assembly ( 1).
5-6 Agilent 87130A Operating and Service Manual Replaceable Parts T able 5-3 Replaceab le Parts - 87130A Chassi s Assembly ( 2) Part Location Part Number Quantity Description 1 5021-8401 1 Front fr am.
Agilent 87130A Operating and Service Manual 5-7 Replaceable Parts Figure 5-2 87130A Chassi s Assembly ( 2).
5-8 Agilent 87130A Operating and Service Manual Replaceable Parts 1 Required fo r 220V options T able 5-4 Replac eable Part s - 87130A Cable As sembly Part Location Part N umber Quantity Description R.
Agilent 87130A Operating and Service Manual 5-9 Replaceable Parts Figure 5-3 87130A Cable Assembly.
5-10 Agilent 87130A Operating and Service Manual Replaceable Parts.
Agilent 87130A Operating and Service Manual 6-1 6 T r oubleshooting Overview I n this cha pter you wi ll find: • How to check the fuses and power s upply • How to set up the EPROM af ter rep lacem.
6-2 Agilent 87130A Operating and Service Manual Troubleshooting Troubleshoo ting T roubleshooting If your instrument is still in warrant y we stron gly recommend that you s end the en tire unit b ack to Ag ile nt T ec hnolo gie s for r epa ir . A procedur e for che cking the fu ses and p ower supply is given on page 6-4 .
Agilent 87130A Operating and Service Manual 6-3 Troubleshooting Troubleshoot ing Figure 6-1 87130A DC Schemat ic.
6-4 Agilent 87130A Operating and Service Manual Troubleshooting Fuse and Power Supp ly Check Fuse and Power Supply Check Fuse Check If the attenuat or/switc h driver f ails to respond whe n the power s witch is turned on, t he power line fuse should be check ed.
Agilent 87130A Operating and Service Manual 6-5 Troubleshooting Procedure f or Setting Up the EPROM Pr ocedure for Setting Up the EPROM Use the f ollowing pr ocedure to s et up the EPROM af ter the EPROM or the CPU board has been repl aced.
6-6 Agilent 87130A Operating and Service Manual Troubleshooting Procedure for S etting Up the EPROM.
Index Agilent 87130A Operating and Service Manual Index-1 A accessorie s, description, 5-13 ADD, 4-27 address channel , 2-4 dri ver ca rd, 2-11 factory preset , 2-3 GPIB, 2-3 switch dr iver, 4 -4 AUTO.
Index-2 Agilent 87130A Operating and Service Manual comp ound , 4-5 optio ns, 4-6 I I/O data cable descri ption , 2-13 pin fu nction s, 2-13 IDN, 4-16 If, 6-2 initiali zation, 4-9 INIT ialize, 4-48 in.
Agilent 87130A Operating and Service Manual Index-3 SA VE, 4-5 9 ST A Tus, 4-6 0 SYST em, 4 -61 TRIGger, 4-62 VA L u e , 4 - 6 3 VERify, 4-64 VERsion , 4-66 WID Th, 4-67 selecting m ultiple subs ystem.
Index-4 Agilent 87130A Operating and Service Manual.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Agilent Technologies 87130A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Agilent Technologies 87130A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Agilent Technologies 87130A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Agilent Technologies 87130A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Agilent Technologies 87130A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Agilent Technologies 87130A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Agilent Technologies 87130A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Agilent Technologies 87130A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.