CHILLER (“CH” SERIES) Operator ’ s Manual Models: CH 250 CH 251 PRINTED IN U.S.A IMI CORNELIUS INC; 1999–2002 IMI CORNELIUS REMCOR INC g 500 REGENCY DRIVE g GLENDALE HEIGHTS, IL 60139–2268 T elephone (800) 551–4423 Facsimile (800) 519–4423 Part No.
i 620914801 T ABLE OF CONTENTS Page GENERAL INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INTRODUCTION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 620914801 GENERAL INFORMA TION INTRODUCTION The REMCOR ” CH ” Series Recirculating W ater Chiller is designed to provide an accurate, reliable, and user – friendly system for cooling a continuous flow of water and keep it at a constant temperature in various closed loop or tank cooling applications.
2 620914801 When servicing a REMCOR Chiller , it is important to note the information contained on the data plate located in the upper rear of the Unit. If technical assistance is needed, the phone technician will need the Serial Number of your Chiller .
3 620914801 radiators, hot water pipes, etc. Any lengths of tubing that are exposed to high ambient temperatures should be insulated to prevent condensation and/or significant liquid heat loss.
4 620914801 1. Push the “ SET ” button located to the right of the digital display . The current set-point will be displayed. 2. Push the “ UP ” or “ DOWN ” button until the desired set-point is displayed. 3. After approximately 3 seconds, the display will show the system water temperature.
5 620914801 FLUID RECOMMENDA TION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40 _ F – 100 _ F.
6 620914801 TROUBLESHOOTING W ARNING: Disconnect electrical power to the Chiller to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring. If repairs to the Chiller must be made, disconnect electrical power to the unit, then shut off the water source.
7 620914801 FIGURE 3. WIRING DIAGRAM (1 15V) R S C COMPRESSOR LIGHT , POWER ON M ELECTRICAL WIRING DIAGRAM OVERLOAD 4 M 3 1 15/1/60 COMPRESSOR 1 24V 1 15V ST ART RELA Y ST ART CAP ACIT OR M 9 1 5 8 6 .
8 620914801 FIGURE 4. WIRING DIAGRAM (230V) R S C COMPRESSOR LIGHT , POWER ON M ELECTRICAL WIRING DIAGRAM 2 OVERLOAD 4 M 3 230/1/60 COMPRESSOR 1 24V 230V ST ART RELA Y ST ART CAP ACIT OR M 9 1 5 8 6 P.
9 620914801 7 3 9 11 10 15 14 6 4 2 1 16 13 12 18 8 5 17 FIGURE 5. CABINET SECTION EXPLODED VIEW Item No. Part No. Name 1 32386 T emperature Controller 2 31934 Power Switch 3 61014 Evaporator 4 620023502 W rapper Panel 5 51882 Priming Reservoir Ass ’ y 6 24388 Panel, Left Side 7 60992 Compressor 8 31955 Pump 9 24390R Base Ass ’ y Item No.
.
10 620914801 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you.
IMI CORNELIUS INC. CORPORA TE HEADQUARTERS: One Cornelius Place Anoka, Minnesota 55303-6234 (763) 421-6120 (800) 238-3600 9 620914801.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cornelius CH 250 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cornelius CH 250 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cornelius CH 250 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cornelius CH 250 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cornelius CH 250, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cornelius CH 250.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cornelius CH 250. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cornelius CH 250 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.