Manuale d’uso / di manutenzione del prodotto Accord Series del fabbricante Cooper Lighting
Vai alla pagina of 16
Accor d Series T5/T8 Enhanced Lighting System.
1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual Perception 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Comparison 7 . . . . .
2 Improve visual perception • The accord TM evenly distributes light, making the space more pleasing to the eye. • Dark spots (cave effect) associated with parabolics are eliminated. Attractive design • Smooth, cur ved surfaces are attractive but subtle.
Parabolics are designed to direct light into the cut-off zone, while restricting light into the shielded or glare zone. In other words, parabolics deliver light to the work plane and suppress high-angle brightness. Due to the high-angle cutoffs as shown in Figure 1.
SHIELDED ZONE CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 1. Parabolic Light Distribution MINIMIZED SHIELDED ZONE ENHANCED CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 2. accord TM Light Distribution Attractive contemporary design • Smooth, cur ved surfaces are attractive but subtle.
accord TM 2 Lamp, T5 accord TM (2) 28W T5 lamps, 18 fixtures step-dim electronic ballast (.95 ballast factor) 63 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.76 41 25 IES* accord TM maximizes savings Choose either T5 or T8 technology to best meet your lighting needs.
T roffer 4 Lamp T ypical 4 lamp troffer (4) 32W T8 lamps, 12 fixtures electronic ballast (.87 ballast factor) 122 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.98 50 23 IES* accord TM 2 Lamp, T8 accord TM (2) 32W T8 lamps, 12 fixtures electronic ballast (1.
Appearance and performance make accord TM the lighting choice. Energy savings makes accord TM a sound financial decision. The accord TM family of products saves up to 40% energy costs when compared to a standard 3 lamp,18 cell parabolic. The dimming feature reduces energy consumption by another 50%.
COST PER kWh Hours of Oper ation $0.06 $0.08 $0.1 0 $0.1 2 $0.1 4 P er Day P er Y ear 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 12 hrs. 4,380 $16.03 $7.88 $21.37 $10.51 $26.72 $13.14 $32.06 $15.76 $37.41 $18.36 18 hrs. 6,570 $24.04 $1 1.
• 3-13/16" low profile housing Surface Mount av ailable Low profile and quality performance – the surface accord TM is an energy efficient alternative to traditional surface mount fixtures. Designed for areas without a grid-ceiling type system, the accord’ s TM low profile is an ideal retro-fit solution.
Diffuser Options Square Perf Design (SQP) Smooth acrylic diffuser with square perforated insert (2' x 2', 2' x 4' only) Round Perf Design (RPD) Smooth acrylic diffuser with round p.
accord TM - 1' x 4', T5 accord TM - 1' x 4', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 AC-128T5 Electronic Ballast (1) F28T5/835 Lamp 260 0 Lumens Spacing criterion: (II) 1 .
accord TM - 2' x 2', T5 accord TM - 2' x 2', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 2AC-214T5 Electronic Ballast (2) F14T5/835 Lamps 1350 Lumens Spacing criterion: (II) 1 .
T5 Ordering Information SAMPLE NUMBER: 2AC-228T5-UNV-L5841-EBT1NDIM-U Number of Lamps (Not included) 1 =1 Lamp (1' x 4' only) 2 =2 Lamp (2' x 2', 2' x 4' only) W attage (.
• The accord TM can provide up to 40% energy savings when compared to a 3 lamp, 18 cell, T8 parabolic. • The accord TM also exceeds mandated energy regulations such as California’ s Titl e 24 and ASHRAE 90.1 2001. • Step dimming can increase energy s av ings by as much as 50%.
Printed in USA ADF080670 Cooper Industries, Ltd. 600 T ravis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www .cooperindustries.com Cooper Lighting and Metalux logos are valuable trademarks of Cooper Industries in the United States and other countries.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cooper Lighting Accord Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cooper Lighting Accord Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cooper Lighting Accord Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cooper Lighting Accord Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cooper Lighting Accord Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cooper Lighting Accord Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cooper Lighting Accord Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cooper Lighting Accord Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.