Manuale d’uso / di manutenzione del prodotto Industrial Ethernet 3000 Series del fabbricante Cisco
Vai alla pagina of 30
G ETTING S TARTED G UIDE Cisco Catalyst Blade Sw itch 3000 Series for HP Getting Started Guide 1 About This Guide 2 T aking Out What Y ou Need 3 HP Blade System Arc hitecture 4 Installing the Switc h .
2 1 About This Guide This guide provides in structions on how to install your C isco Catalyst Blade Switch 3120 for H P or Cisco Catalyst Blade S witch 3020 for HP— referred to as the switch module —in the HP c-Class BladeSystem and how to set up and configure your switch module.
3 2 Taking Out What You Need Follow these steps: 1. Unpack and remove the switch module and the accessory kit from the shipping box. 2. Return the packing material to the shipping container , and save it for future use. 3. V erify that you hav e received the items shown on p age 3.
4 Cisco Switch Modu le Descriptions These sections describe the switch modules: • Cisco Catalyst Blade Switch 3120 for HP , page 4 • Cisco Catalyst Blade Switch 3020 for HP , page 6 The switch module is powered from the bla de enclos ure backplane.
5 Figure 1 shows the Cisco C atalyst Blade Switch 3120 for HP switch module. Figur e 1 The Catalyst Blade Switc h 3120 f or HP 1 Switch module 8 LEDs for ports 19 and 20 2 UID 1 LED 1.
6 T able 1 describes the Cisco Catalyst Blade Switch 3120 for HP switch modu le ports. Each external port has an associated LED. Cisco Catalyst Blade Switch 3020 for HP The Cisco Catalyst Blade Switch 3020 for HP is a 24-Gigabit Ethernet port, Layer 2+ switch module.
7 Figure 2 shows the Cisco C atalyst Blade Switch 3020 for HP switch module. Each external p ort has an associated LED. Figur e 2 The Catalyst Blade Switc h 3020 f or HP 1 Switch module 7 Health LED 2.
8 T able 2 describes the switch module ports. Ea ch external port has an associa ted LED. T able 2 Cisco Catalyst Blade S witc h 3020 fo r HP P ort Descr iptions Port Description Ports 1 to 16 Internal Gigabit Ethernet 1000BA SE-X downlink ports. Ports 17 to 20 and Ports 17x to 20x Dual-purpose SFP module/RJ-45 copper Ethernet uplink ports.
9 3 HP Blade System Architecture Figure 3 shows the rear view of the blade enclos ure, in which you instal l the switch module. Figur e 3 Rear View of the Blade Enclosure 1 Blade enclosure rear view 7.
10 Consider these prerequisites before you install the switch module: • Fill any unoccupied interconn ect bays or any unoccupied power module ba ys in the blade enclosure with blanks. • Identify the b ays in which you will i nsert the switch modu les.
11 Follow these steps to install the switch module in the blade enclosure. The illustratio ns in this section show the Cisco Catalyst Blade Switch 3020 for HP switch module. The instructions are the same for the Cisco Catalyst Blade Switch 3120 for HP sw itch module.
12 Step 4 Ensure that the release latch on the switch module is in the open position (perpendicular to the module) : Step 5 Slide the switch module into the bay until it stops.
13 Step 6 Push the r elease latch on the front of the switch module to th e closed position. 5 Using the Onboard Administrato r to Assign an IP Address to the Switch Module and Running Express Setup F.
14 Step 4 Using a PC that is conn ected to the same ne twork segment as the blade enclosure Onboa rd Administrator , access the Onboard Administrator in a browser window .
15 Figur e 6 Expr ess Setu p P ag e fo r the Cisco Catalyst Blade Switc h 3120 f or HP Figur e 7 Expr ess Setu p P ag e fo r the Cisco Catalyst Blade Switc h 3020 f or HP Step 8 Go to “Using Express Setup” to finish setting up the switch module.
16 Using Express Setup Before you complete the setup program, obtain the default gateway IP address and the switch password from your system administra tor .
17 Figure 8 A dv anced Settings T ab Step 2 In the Host Name field, enter a name for the switch m odule. The host name is limited to 31 characters; embedded space s are not allowed. Step 3 In the System Date and System T ime fields, enter the current date and time, or use the down arrows to select them.
18 Step 9 If you enable SNMP , you must enter a community string in the SNMP Re ad Community field, the SNMP W rite Community field , or both. SNMP communi ty strings authenticate access to MIB objects. Embedded spaces are not allowed in SNMP co mmunity strings.
19 Step 6 Enter end . Step 7 Enter copy running-configuratio n startup-configuration to save this setting. Step 8 At the prompt, press Return . Step 9 T o verify that this switch is set as t he stack ma ster , en ter the show switch user EXEC command.
20 Figur e 9 Device Manager P age f o r the Ci sco Catalyst Blade Switc h 3120 for HP.
21 Figur e 1 0 Device Manager P age f or the Cisco Catalyst Blade Switc h 3020 for HP Step 3 Use the device manager to perform basic switch module configuration and mo nitoring.
22 Step 3 Configure the PC terminal emulation software for: – 9600 baud – 8 data bits – No parity – 1 stop bit – No flow control Step 4 Use the CLI to enter commands to config ure the switch module. See the software configuration guide a nd the command reference for more information.
23 7 Planning and Creating a Switch Stack (Only the Cisco Catalyst Blade Switch 3120 for HP) A switch stack is a set of up to nine stacking-capab le switch modules that are connected through their StackWise Plus ports. One of the switches controls the operation of the sta ck and is called the stack master .
24 – CAB-STK-E-0.5M= (0.5-meter cable) – CAB-STK-E-1M= (1-meter cable) – CAB-STK-E-3M= (3-meter cable) For switch module dimensions and additional stacking guidelines, see the switch module hardware installation guide.
25 Step 3 Insert the cable into the S tackWis e Plus port on the front panel of the switch. Insert the other end of the cable into the connector of the other sw itch.
26 The autonegotiation feature is enabled by defaul t on the switch. At this setting, the switch module ports configure themselves to operate at the speed of at tached devices. If th e attached device does not support autonegotiation, you can explicitly set the switch module port speed and the duplex parameters.
27 Verify Port Connectivity After you connect a device to the switch module port, the port LED turns a mber while the switch module establishes a link. This process takes about 3 0 seconds. Then the LED turns green when the switch module and the a ttached device have an estab lished link.
28 Accessing Help Online First look for a solution to your problem in the tr oubleshooting section of the hardware installation guide or software configuration guide for your swit ch module on Cisco.
29 10 Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitti ng a service request, and gathering additional information, see the monthly What’ s New in Cisco Product Documentation , which also lists all new and revised Cisco technical documentation, at: http://www .
Americas Headquarte rs Cisco Systems, I nc. 170 W est T asman Drive San Jose, CA 95 134-1706 USA www .cisc o.com T el: 40 8 526-4000 800 553-NETS (63 87) Fax: 408 527-0883 Asia Pacific Headquarters Cisco Systems, Inc. 168 Robinson Road #28-01 Capital T ower Singapore 068912 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cisco Cisco Industrial Ethernet 3000 Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cisco Cisco Industrial Ethernet 3000 Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cisco Cisco Industrial Ethernet 3000 Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cisco Cisco Industrial Ethernet 3000 Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cisco Cisco Industrial Ethernet 3000 Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cisco Cisco Industrial Ethernet 3000 Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cisco Cisco Industrial Ethernet 3000 Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cisco Cisco Industrial Ethernet 3000 Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.