Manuale d’uso / di manutenzione del prodotto DMX512 del fabbricante Chauvet
Vai alla pagina of 19
Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle MiN™ S pot USER MANUAL Chauvet, 3000 N 2 9 th Ct, Hollywood, FL 3 3020 U.S.A. (800) 762-1084 – (954 ) 929-1115 FAX (954) 929-5560 www.
T ABLE OF C ONTENTS MiN™ Spot ..................................................................................................................... ................................ 1 USER MA NUAL .....................................................
1. B EFORE Y OU B EGIN What is included ¾ 1 x MiN™ Spot ¾ Power Cord ¾ Warranty Card ¾ User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition.
Safety Instructions Please read these instructions carefully, it includes important information about the installation, usage and maintenance of this product. • Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2. I NTRODUCTION Features CONTROL FEATURES • 5 or 13-channel DMX-512 LED moving yoke • Pan: 540 o / tilt: 270 o • RGB color mixing • Gobo wheel 9 gobos + open Gobo wheel spin effect • Variab.
DMX Channel Summary - 5 Channel Mode C HANNEL F UNCTION 1 Pan 2 Tilt 3 Shutter 4 Color Macro 5 Gobo Product Overview Projector Head Lens Focus LED Readout Control Panel DMX In DMX Out IEC Power Connec.
3. S ETUP Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement The fuse is located inside this With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse.
CABLE CONNECTORS CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the othe r end. Cabling must have a male XLR connector on one end and a female XLR connector on the othe r end. 2 1 3 OUTPUT Termination reduces signal er rors.
Master/Slave Fixture Linking 1. Connect the (male) 3 pin connector side of the DM X cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixtur e consisting of a (male) 3 pin connector.
4. O PERATING I NSTRUCTIONS Navigating the Control Panel Access control panel functions using the four pa nel buttons located directly underneath the LCD Display.
Menu Map MiN™ Spot User Manual 11 2008-07-15/12 :39.
User Configurations TO SET THE PAN TO INVERTING OR NON-INVERTIN G: 1) Press the Mode button until it shows or 2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
Stand-Alone Mode ( Auto Mode): This mode allows a single unit to run to a factory installed program in one of two speeds. 1) To set the fixture in auto mode Fast , select .
DMX Channel Values (13 Channel) C HA NNE L V ALU E F UNCTION 1 000 Ù 255 Pan 2 000 Ù 255 Pan Fine 3 000 Ù 255 Tilt 4 000 Ù 255 Tilt Fine 5 000 Ù 255 V ector Speed: (Normal → Slow) 6 000 Ù 007 .
DMX Channel Values (5 Channel) C HANNEL V AL UE F UNCTION 1 000 Ù 255 Pan 2 000 Ù 255 Tilt 3 000 Ù 007 008 Ù 134 135 Ù 239 240 Ù 255 Dimmer/Strobe Closed 100-0% Strobe (slow → Fast) Open 4 000.
Troubleshooting Symptom Solution(s) Applies to Lights Foggers & Snow Controllers Dimmers & Chaser Auto shut off Check f an thermal switch reset 9 Beam is very dim or not bright Clean optical s.
Technical Support Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A. ) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Pre ss 4) Fax: (954) 929-5560 - (Att ention: Service) Website: http://www.chauvetlighting.com 6.
General Maintenance To maintain optimum performance and minimize we ar fixtures should be cleaned frequently. Usage and environment are contributing factors in determi ning frequenc y. As a general rule, fixtures should be cleaned at least twice a month.
MiN™ Spot User Manual 19 2008-07-15/12 :39 Technical Specifications WEIGHT & DIMENSIONS Length......................................................................................................................... .... 6.8 in (173 mm) Width ..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Chauvet DMX512 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Chauvet DMX512 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Chauvet DMX512 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Chauvet DMX512 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Chauvet DMX512, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Chauvet DMX512.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Chauvet DMX512. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Chauvet DMX512 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.