Vai alla pagina of 18
CAPPUCCINO, COFFEE, and SOUP DISPENSERS GB POUROVER models : •GB1P •GB2P •GB3P •GB4P OPERA TION MANUAL • Specifications 2 • Installation and Operating Instructions 3 • Adjustments 4 • .
Electrical Specifications Model No. Volts Phase Hz Watts Number of Heaters Amps Receptacle Nema No. Circuit Breaker GB1P, GB2P, GB3P GB4P 120V 1 60 1.8KW 1 15 5-15R 15A GB1P, GB2P, GB3P, GB4P 120/240V or 240V 1 50/60 50/60 3.0KW 3.0KW 1 15 15 L14-20R** L6-20R 20A 20A 120V, 1.
3 START UP INSTRUCTIONS FOR GB POUROVER CAPPUCCINO DISPENSER (see illustration 9-3 for clarification) I. INSTALLATION INSTRUCTIONS This equipment is to be inst alled to com ply with the applicable Fe deral, State, or l oca l p lumbing codes hav ing jurisdiction.
III. PRIMING - AUTOFILL - Water Selection Switch - To ggle Down (See B a ck Panel) 1. Plug into power outlet. 2. Turn Heater Switch ON. 3. Allow 10 to 15 minutes for water t o reach dispense temperat ure of 185°F. Heater Indicator Light (red) goes ON when heater is on (see lower front panel).
HOPPER COVER CD106 5 AUGER GEAR – FOR RE CTANGULAR HOPPE RS: CD117 [Used With Nylon Auger CD130] CD117 [Used With Wire Auger CD101 &CD130] FRONT BUSHING: Rectangular Hoppers: CD277 [ Ø 22.5 mm ] CD306 [ Ø 17 mm ] Square Hoppers: CD102 [ Ø 2 2.
DRINK SIZE ADJUSTMENTS (OPTIONAL FEATURE) a. Manual Dispen se Machines: Hold down the Dispense Button until desired amoun t is dispensed. b. Automatic Machines wit h Programmable "Teach m e" Timers [L576A or L582A]: The timer is progr amm able from the dispen se button.
TEST T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 T5 N L1 4 3 2 1 A ) Water Inlet Valve Test Check Valve Ass’y L463A Check Valve Ass’y L463A Check Valve Ass’y L463A Turn power off.
TROUBLESHOOTING GUIDE FOR GB-POUROVER WARNING: To reduce the risk of electr ical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact.
9 MAINTENANCE To Replace The Picture / Duratr an GB w/ Metal Doors Only: Lift up the two end tabs o n top of door with a pointe d o bject or flat h ead screwdriver. Pull the entire pict ure frame out. Open up the two c lear pa nels and replac e picture.
10 CLEANING AND SANITIZING Sanitizing: All sanitizing agents in the food zone must comply with 21 CFR 178.1010. All food dispensing units should be sani tized periodically. All parts to be sanitize d must be cleaned first. To prepare a sanitizing solution: Add 2 Tsp.
RESERVOIR AND TANK ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 14 13 17 15 16 21 20 19 18 3 7 Q174Q RESERVOIR ASSEMBLY ITEM P/N QTY DESCRIPTION 1. Q174A 1 P.O.-LINE TANK(GB3M/ICAP) 2. L499P 1 FLOA T SWITCH 70-V-A 3. M461A 3 DIRECT MOUNTING SEAL (.466 ID) 4. K402A 1 LEVEL CONTROL, 5.
DESCRIPTION AND LOCATION OF COMPONENTS (GB3P SHOWN) CCW CCW CCW 15 19 17 10 11 13 12 14 9 23 22 26 25 24 27 31 30 29 28 33 34 32 37 36 35 39 38 42 40 41 46 47 45 44 7 8 1 62 61 52 50 51 48 53 58 57 59.
ITEM DESCRIPTION GB1P GB2P GB3P 1 WATER BOTTLE 3 gal / OR 6 gal M518A / M519A M518A / M519A M518A / M519A 2 RESERVOIR /COVER 97128 97128 97128 3 RESERVOIR ASSY Q174Q Q174Q Q174Q 4 SILICONE HOSE - RESE.
14 N L1 L1 L1 MAIN UNIT DOOR UNIT N N N N N N N N N N L1 L1.
15 N N L1 L1 N N N N N N N N L1 L1 L1 MAIN UNIT N DOOR UNIT + +.
16 L1 L1 DOOR U NIT N N N N N N N N N N N L1 L1 L1.
N N N N N N N N N N L1 L1 L1 L1 L1 N DOOR UNIT + + + MAIN UN IT 17.
N N N N N N N N N N L1 L1 L1 L1 L1 N DOOR UNIT + + MAIN UNIT 18.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cecilware GB4P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cecilware GB4P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cecilware GB4P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cecilware GB4P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cecilware GB4P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cecilware GB4P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cecilware GB4P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cecilware GB4P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.