Manuale d’uso / di manutenzione del prodotto GB4M-5.5-LD-U del fabbricante Cecilware
Vai alla pagina of 29
Operation Manual NL48A July 2005 GB4M-5.5-LD-U GB5-LD-U GB6M-10-LD-U GB8M-10-LD-U.
CONTENTS Important Owner Information _____________________________________1 Introduction ____________________________________________________1 Important Safety Instructions ___________________________.
IMPORTANT OWNER INFORMATION Record the model number, serial number (identification plate is located behind front door), voltage and purchase date of your Cecilware Cappuccino Dispenser in the spaces below. Please have the information available when calling Cecilware for assistance.
IMPORTANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property. IMPORTANT SAFETY INSTRUCTIONS WARNINGS The GB8M - 10 - LD - U ( only ) is e quipped with two (2) power switches and two (2) 120 volt grounded power cords.
PLUG CONFIGURATION NEMA 5-15P NEMA 5-15R NEMA 5-15P NEMA 5-15R (2) DEDICATED OUTLETS 120 V 15 A Figure # 1 FOR GB8 MODELS ONLY MODEL DESCRIPTION GB8M - 10 - LD - U (shown) GB6M - 10 - LD - U (typical) These High V olume Cappuccino Dispensers will hold double the amount of your most popular flavor along with up to seven other flavors as well.
UNPACKING INSTRUCTIONS Carefully unpack the Cappuccino Dispenser Unit and inspect immediately for shipping damage. Your Cappuccino Dispenser Unit was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory.
START - UP PROCEDURE C aution: Make sure that the Heater Switches, are in the OFF position. 1. Connect the ¼ inch copper waterlines to the ¼ inch flare water inlet fittings of the valves. 2. Plug the power cords into dedicated receptacles. 3. Activate the Power Switch (Toggl e Up).
TROUBLESHOOTING GU IDE WARNING : To reduce the risk of electrical shock, DISCONNECT POWER CORDS before repairing or replacing any internal components of the unit. Before any attempt to replace a component be sure to check all electrical connections for proper connection .
Model L690A (Rev. B) Dual Probe Liquid Level Controller Overview - The L690A is a Dual Probe Liquid Level Controller designed to maintain a specific level of water in the tank. This device utilizes two level probes for increased reliability. Independent maximum fill timers are incorpor ated in the controller for overflow protection.
PRODUCT GUIDE PRODUCT GUIDE HOPPER (3) (CD185) WHIPPER CHAMBER HEATER LIGHT POWER SWITCH GRILL DRIP TRAY PAN 14.1" RINSE SWITCH 20.0" GRILL DRIP TRAY PAN POWER SWITCH RINSE SWITCH WHIPPER CHAMBER HEATER LIGHT UPPER DOOR OPEN GB4M- 5.5-LD-U 4 Flavor Cappuccino Dispenser Upper Door open, Lower Door not shown.
10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD185) 10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD180) 27.0" 21.5" DRIP TRAY PAN GRILL DRIP TRAY PAN (2) GRILL SLANTED WHIPPER CH.
11 5 7 1 12 8 6 4 3 10 2 9 WHIPPER CHAMBER 13 IMPORTANT: SLANTED WHIPPER CHAMBERS (SEE BELOW) ARE NOT INTERCHANGEABLE WITH STANDARD STRAIGHT WHIPPER CHAMBERS.
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 HOPPER COVER AUGER MOTOR #CD175 (90 RPM).
AGITATOR WHEEL W/SPRINGS AUGER BUSHING FRONT CD306 PRODUCT GUIDE, SHORT CD70A AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER.
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM QTY P/N 17.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM GB8 22 GB6 GB5 UPPER DOOR GB4M-5.5-LD-U, GB5-LD-U GB6M-10-LD-U, & GB8M-10-LD-U GB4.
DESCRIPTION ITEM GB6 23 GB8 GB5 GB4 LOWER DOOR GB4M-5.5-LD-U, GB5-LD-U GB6M-10-LD-U, & GB8M-10-LD-U.
DESCRIPTION ITEM QTY P/N 21.
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 12" WIDE, 4.8" DEEP, 16.5" HIGH. APPROX. 3.7 GAL..
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 15" WIDE, 6" DEEP, 18" HIGH. APPROX. 6 GAL..
.
WATER INLET VALVE AUGER DOOR UNIT WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH MAIN UNIT DISPENSE VALVE HI-LIMIT THERMOSTAT HEATER SWITCH RINSE SWITCH A2 44 NO 32 NC 22 NC 14 NO A1 43 NO 31 NC 21 NC 13 NO GND 5-15P 15A-1.
GB6M-10-LD-U.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - LEFT SIDE - 120V NE195 SHEET 1 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHTS REV A.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - RIGHT SIDE - 120V NE195 SHEET 2 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHT REV A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cecilware GB4M-5.5-LD-U è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cecilware GB4M-5.5-LD-U - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cecilware GB4M-5.5-LD-U imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cecilware GB4M-5.5-LD-U ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cecilware GB4M-5.5-LD-U, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cecilware GB4M-5.5-LD-U.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cecilware GB4M-5.5-LD-U. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cecilware GB4M-5.5-LD-U insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.