Manuale d’uso / di manutenzione del prodotto RDVOD 3354 del fabbricante Vermont Casting
Vai alla pagina of 40
INST ALLER / CONSUMER SAFETY INFORMA TION 20004188 6/05 Rev . 12 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPER- TY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
2 2 Radiance Direct Vent/Natural Vent Gas Heater 20004188 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a V ermont Castings stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance Direct V ent/Natural V ent Room Heater , Model Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for V ented Room Heat- ers, and CSA 2.
4 4 Radiance Direct Vent/Natural Vent Gas Heater 20004188 29 " (7.6cm) 31" (7.9cm) 7" Outer Dia. (1.8cm) 4 " (1.
5 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude.
6 6 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natu - ral V ent Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines. ST130 42" (1070mm) Min.
7 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Radiance Direct V ent/Natural V ent Certified to: ANSI Z21.88b-2002 / CSA 2.33b-2002 V ented Gas Fireplace Heaters Gas Specifications Max.
8 8 Radiance Direct Vent/Natural Vent Gas Heater 20004188 V ent T ermination Clearances When planning the installation, consider the location of the vent terminal and clearances. Some of the most c om mo n c le ar an ce s to k ee p in m in d a re s ho wn i n Fi gu r e 9.
9 Radiance Direct Vent /Natural Vent Gas Heater 20004188 V ent T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • CFM Specialty Home Products does not require any opening for inspection of vent pipe.
10 10 Radiance Direct Vent/Natural Vent Gas Heater 20004188 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I .
1 1 Radiance Direct Vent /Natural Vent Gas Heater 20004188 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height.
12 12 Radiance Direct Vent/Natural Vent Gas Heater 20004188 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Stardance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof.
13 Radiance Direct Vent /Natural Vent Gas Heater 20004188 ST720 Radiance slide stove back 7/30/02 djt ST720 Fig. 12 Slide stove back just far enough to access rear leg holes.
14 14 Radiance Direct Vent/Natural Vent Gas Heater 20004188 ST347a JUV FK28 rheostat install 9/21/00 Rheostat Retaining Collar Rheostat Knob ST347a Fig. 17 Attach the fan rheostat. Rheostat Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here.
15 Radiance Direct Vent /Natural Vent Gas Heater 20004188 V enting System Assembly - Direct V ent General Information The Radiance is approved for installation only with the vent components listed on Page 1 1. Follow the vent component instructions exactly .
16 16 Radiance Direct Vent/Natural Vent Gas Heater 20004188 2. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes.
17 Radiance Direct Vent /Natural Vent Gas Heater 20004188 For DuraV ent pipe only: Install vent pipe by align- ing the locking system together , sliding the pipes together and twisting clockwise. • Install 90° elbow . T wist lock as before. • Slide the wall plate over horizontal run before at- taching the horizontal run to the elbow .
18 18 Radiance Direct Vent/Natural Vent Gas Heater 20004188 V ertical (Through the Roof) V ent Assembly Note that all vertically terminated installations must, where specified, use the restrictor plate to comply with V ertical T ermination Window (Page 7, Figure 8), included in the hardware bag.
19 Radiance Direct Vent /Natural Vent Gas Heater 20004188 ST221 vent thru roof 12/99 Storm Collar Sealant Upper edge of flange goes under upper shingles Flashing #7DVSKV (A, B, or F) Roof Support Use three #5 sheet metal screws at each joint ST221 Fig.
20 20 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Install Log Set Before beginning log installation, remove stove front and glass frame. Refer to Figures 36 and 37. ST139 Radiance remov e front 4/20/01 djt ST139 Fig. 36 Remove the stove front.
21 Radiance Direct Vent /Natural Vent Gas Heater 20004188 LG156 Radiance logs 4/23/01 djt LG156 Fig. 39 Install the left and right rear logs and the right log. Decorative Grate Right Log Right Rear Log Left Rear Log Left Bracket Right Bracket 4. Install the right log by engaging hole on the bottom with pin on the right rear log.
22 22 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Thermostat Connection (optional) Use only a thermostat rated for 500 - 750 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
23 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. T o open the front doors, insert the handle into the door latch stub and turn it to the right and up.
24 24 Radiance Direct Vent/Natural Vent Gas Heater 20004188 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2.
25 Radiance Direct Vent /Natural Vent Gas Heater 20004188 T roubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. W ARNING: REMOVE THE GLASS P ANEL BEFORE PERFORMING ANY GAS CONTROL SER VICE WORK.
26 26 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Instructions for RF Comfort Control V alve The Comfort Control valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal.
27 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Auto Mode In the AUTO mode, the room temperature, set tem- perature, flame and fan levels will be shown.
28 28 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Light pilot burner Set manual switch to local or remote Release pilotstat knob. T urn pilotstat knob from PILOT to ON. If manual switch is set to LOCAL, did main burner light and fan turn on? T urn pilotstat knob to PILOT to turn off main burner .
29 Radiance Direct Vent /Natural Vent Gas Heater 20004188 If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter .
30 30 Radiance Direct Vent/Natural Vent Gas Heater 20004188 ST667 RNVOD air shutter converting from NG to Lp 6/4/01 djt Burner Refer to T able 2 ST667 Fig. 54 Adjust air shutter according to T able 2. Conversion Precautions Before proceeding, turn control knob on valve to OFF and turn gas supply OFF .
31 Radiance Direct Vent /Natural Vent Gas Heater 20004188 CO100 Gas conversion HI-LO knob 3/15/99 djt L O H I L O H I Cap Hi-Lo Knob Lift Open Center Screw CO100 Fig. 55 Remove center screw from Hi-Lo knob. 14. T ighten screw (do not over tighten), replace cap.
32 32 Radiance Direct Vent/Natural Vent Gas Heater 20004188 All Models 22. Replace burner . Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base.
33 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Maintenance Y our Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly .
34 34 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Gasket Replacement The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
35 Radiance Direct Vent /Natural Vent Gas Heater 20004188 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIV ALENT .
36 36 Radiance Direct Vent/Natural Vent Gas Heater 20004188 46 1a 1b 1c PILOT ON OFF PILOT ADJ L O H I CEMENT 2 3 6 8 7 5 34 4 35 4188 RDVOD parts 6/1 1/01 djt 32 33 29a,b, c,d 9 30 LOCAL REMOTE ON .
37 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Radiance Direct V ent/Natural V ent Gas Heater (RDVOD) Models 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued) Ref. Description RDVOD 8. Glass, GFP Firebox 1601290 9. Ceramic Handle w/Insert LFTR 0004342 10a.
38 38 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture.
39 Radiance Direct Vent /Natural Vent Gas Heater 20004188 BASIC W ARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or .
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Specialty Home Products Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) RDVODRN 60.7 RDVODRP 60.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting RDVOD 3354 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting RDVOD 3354 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting RDVOD 3354 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting RDVOD 3354 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting RDVOD 3354, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting RDVOD 3354.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting RDVOD 3354. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting RDVOD 3354 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.