Manuale d’uso / di manutenzione del prodotto P720 del fabbricante Lux Products
Vai alla pagina of 26
CAUTIONS AND W ARNINGS . . . . . . . . . . 2 SYSTEM COMP A TIBILITY . . . . . . . . . . . . 3 FEA TURES . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS YOU MA Y NEED . . . . . . . . . . . . . . 4 MOUNTING LOCA TION . . . . . . . . . . . . . . 5 REMOVE OLD THERMOST A T .
2 • This thermostat requires batteries to opera te and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell ® or Energizer ® alkaline batteries ONL Y for all LUXPRO thermostats requiring batteries.
Se t Ne xt H o ld F an A ut o O n H e at O ff C oo l LCD Display Screen P721 UP and DOWN Buttons Fan Mode Switch SET , NEXT , and HOLD Buttons System Mode Switch The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combined load of 2.
• 7-day programming, 5/2-day programming, or non-programmable options • All days can be programmed separately • User -selectable periods per day (2 or 4) • Lighted display • Keypad lockout f.
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.
1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. F ill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’ s normal opera tion. 3. Separate new thermostat housing using your thumb and index finger .
CONNECTING THE WIRES: When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the terminal block while the screw is being tightened. WIRING BASE PLA TE NOTICE: This thermostat model is part of a family of similar models that have the same general visual appearance.
WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSIST ANCE” section of this manual, and contact us before removing any of your existing thermostat wiring.
9 #1 CONVENTIONAL: HEA TING ONL Y .................................................. 1 0 1-ST AGE 2, 3, 4 WIRES #2 CONVENTIONAL: HEA TING ONL Y .................................................. 1 1 2-ST AGE 3, 4, 5 WIRES #3 CONVENTIONAL: COOLING ONL Y .
2 / 3 / 4 WIRES CONVENTIONAL, NON HEA T PUMP 1-ST AGE, HEA T ONL Y (INCLUDING MILLIVOL T) NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G RH V R Fa.
3 / 4 / 5 WIRES CONVENTIONAL, NON HEA T PUMP 2-ST AGE, HEA T ONL Y NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G RH V R Factory RH-RC Jumper Wire.
Y1 6 Y A/C UNIT 3 / 4 WIRES CONVENTIONAL, NON HEA T PUMP 1-ST AGE, COOL ONL Y NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G Factory RH-RC Jumper Wire In.
Y1 6 Y A/C UNIT 4 / 5 / 6 WIRES CONVENTIONAL, NON HEA T PUMP 1 OR 2-ST AGE HEA T AND 1-STAGE COOL NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G R.
Y1 6 Y A/C UNIT 5 / 6 / 7 WIRES CONVENTIONAL, NON HEA T PUMP 1 or 2-HEA T / 1-COOL, WITH TWO-TRANSFORMERS NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W.
INST ALL BA TTERIES INTO THERMOST A T : Install two brand new Energizer ® o r DURACELL ® “AA ” size alkaline (only) batteries, into the thermosta t’ s battery compartment.
HEA T / OFF / COOL, SY STEM MODE SWITCH: Set this switch to HEA T to control your heating system, and COOL to control your cooling system. The OFF position will disable both the heating and cooling units.
Setup options for how the thermostat will function, along with choosing your particular system type, are performed using a menu on the display screen. TO ACCESS THE SETUP MENU: Move the System Mode switch into the OFF position, and then hold down the SET button for approximately 5 seconds until the screen changes.
[3] Limit 65F (18C). The maximum cooling set temperature is 65F (18C) degrees. [4] Limit 75F (24C). The maximum cooling set temperature is 75F (24C) degrees. ITEM #06 (ST AGE-2 OFFSET): [2, default] This setting is adjusted as a number from 0 to 9. When set to 0 (ZERO), the second heating stage (W2 terminal) is completely disabled.
SET D A Y AND TIME: Place the System Mode switch into the OFF position. Press the SET button one time and the backlight will illuminate; press the SET button again and the room temperature will disappear from the screen and the day icon will flash. With the day flashing, press UP or DOWN to adjust the day of the week shown on the screen.
LCD DISPLA Y BACKLIGHT : The display screen is lighted to assist viewing at nighttime, or in locations with low light levels. A press of any button on the front panel will light the display for approximately 10 seconds.
21 By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DA Y , EVE, and NITE. Each period ends at the start time of the following period. The heat programs are set in HEA T mode, and the cool programs are set in COOL mode.
FOR 7-DA Y PROGRAMMING OPTION: Y ou will be setting each day individually, one at a time. After any particular day’ s program has been set, you will have the ability to copy these values either to just the next day or to the remaining days left in the week (described further below).
KEYP AD LOCKOUT : Y ou can lock the front panel buttons to prevent unauthorized tampering of your thermostat settings. TO LOCK THE KEYP AD: Start with the thermostat at rest, and the display backlight NOT illuminated.
This thermostat is powered by two “AA ” Alkaline batteries. The batteries should be replaced A T LEAST once per year to ensure reliable operation (or sooner if “LO BA TT” appears in the display screen). The batteries are located on the back of the thermostat’ s circuit board.
If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions.
26 www .luxproproducts.com 856-234-8803 S et N ex t H ol d F a n A u t o O n H e a t O f f C o o l LUX PRO.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lux Products P720 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lux Products P720 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lux Products P720 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lux Products P720 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lux Products P720, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lux Products P720.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lux Products P720. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lux Products P720 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.