Manuale d’uso / di manutenzione del prodotto AC282AFERA del fabbricante Haier
Vai alla pagina of 31
Operation & Installation Manual No. 0010577967 A Please read this operation manual before using the air conditioner . Please keep this manual carefully and safely .
Contents Cautions ........................................................................... Safety Precautions ........................................................... Features and Functions ................................................... Name of Parts .
Cautions For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Always grip plug firmly and pull straight out from the outlet.
2 Cautions T emperature and Humidity Range If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage.
3 Safety Pr ecautions W ARNING! DANGER! Do not attempt to install this air conditioner by yourself. This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit.
4 Safety Pr ecautions W ARNING! Provide occasional ventilation during use. Do not direct air flow at fire places or heating apparatuses. Do not climb on and place objects on the air conditioner . Do not hang objects from the indoor unit. Do not set flower vases or water containers on top of the air conditioner .
5 Featur es and Functions AUTOMA TIC OPERA TION SLEEP HEA T & COOL TYPE Merely press the ON/OFF button, and the unit will begin automatic operation in any of the Heating, Cooling and Blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
6 Featur es and Functions VER TICAL AIR DIRECTION ADJUSTMENT Use the air direction adjustment within the ranges shown above. HORIZONT AL AIR DIRECTION ADJUSTMENT Each time the button is pressed, the air direction range will change as follows: Press the AIR FLOW DIRECTION VER TICAL SET button.
Each time the button is pressed, the air direction range will change as follows: Featur es and Functions 7 The swing range of up-down flap is as follow : air direction louvers RIGHT/LEFT 1 2 3 4 5 3 2.
Name of Parts 8 1 Operating Control Panel 2 Emergency switch 3 Power Indicator Lamp 4 OPERA TION Indicator Lamp 5 TIMER Indicator Lamp 6 Compressor Lamp 7 Remote receiver 8 Inlet Grill ( Filter inside.
9 The following four procedures are for series 282, 362, 422, 482, 602. 1. Pull the filters upward to remove them from the Intake Grill. 2. Clean the air filter: Remove the dust from the filters by vacuum cleaner or washing them. After washing, allow the air filters to dry thoroughly in an area protected from sunlight.
10 Operation T ips Operation and Performance *Heating Performance *Microcomputer-contr olled Automatic Defrosting Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.
1 1 W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner .
1 . SELECTING THE MOUNTING POSITION For authorized service personnel only W ARNING W ARNING CAUTION Installation of Indoor Unit 12 Be careful not to scratch the room air conditioner when handing it. After installation, explain correct operation to the customer , according to the operating manual.
FOR HALF CONCEALED INST ALLA TION (1) Install the indoor unit level on a strong wall which is not subject to vibration. Installation of Indoor Unit 13 (2) The inlet and outlet ports should not be obstructed : the air should be able to blow all over the room.
INST ALLA TION PROCEDURE Install the room air conditioner as follows: CONNECTION PIPE REQUIREMENT T able 1 Model Diameter Liquid side Gas side Maximum length Maximum height (between indoor and outdoor) 9.52 mm 19.05mm 50 m 30 m 14 Installation of Indoor Unit 1.
15 Installation of Indoor Unit 3. DRILLING THE HOLES AND A TT ACHING THE SUAPENSION BOL TS IF USING ANCHOR BOL TS (1) Drill holes for anchor bolts at the locations at which you will set the suspension bolts. Note that anchor bolts (to be obtained locally).
FOR HALF-CONCESLED INST ALLA TION In order to check the drainage, be sur e to use a level during installation of the indoor unit. If the installation site of the indoor unit is not level, water leskag.
INST ALLING THE COUPLER HEA T INSULA TION After checking for gas leaks, insulate by wrapping insulation around the two parts (large and small) of the indoor unit coupling, using the coupler hest insulation. After installling the coupler heat insulation, wrap both ends with vinyl tape so that there is no gap.
18 Installation of Indoor Unit DRAIN PIPING Install the drain pipe with downward gradient (1/50 to 1/100) and so there are no rises or traps in the pipe. Use general hard polyvinyl chloride pipe (VP25)[outside diameter 38 mm.] During installation of the drain pipe,be careful to avoid applying pressure to the drain point of the unit.
19 Installation of Indoor Unit (1) Install insulation for the drain pipe.(See Fig.12 and 13) Cut the included insulation material to an appropriate size and adhere it to the pipe. Insulation for Drain pipe (T o be obtained locally .Length shoud be at least 8mm.
20 Installation of Indoor Unit ELECTRICAL WIRING HOW TO CONNECT WIRING TO THE TERMINALS (1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm) of expose the solid wire. (2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
21 Installation of Indoor Unit CAUTION (1) Match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring may cause burning of the electric parts. (2) Connect the connection cords firmly to the terminal block.
22 Installation of Indoor Unit FRESH-AIR INT AKE (1)Open up the knockout hole for the fresh-air intake,as shown in Fig.16 (If using half-concealed installation ,open up the top knockout hole instead) CAUTION (1)When removing the cabinet(iron plate),be careful not to damage the indoor unit internal parts and surrounding area(outer case).
W ARNING (1) Remove the cord clamp. (2) Process the end of the connection cords to the dimensions shown in Fig.19. (3) Connect the end of the connection cord fully into theterminal block. (4) Fasten the connection cord with a cord clamp. (5) Fasten the end of the connection cord with the screw .
TEST RUNNING 1. CHECK ITEMS (1) INDOOR UNIT (1) Is operation of each button on the remote control unit normal? (2) Does each lamp light normally? (3) Do not air flow direction louvers operate normally.
25 T r ouble Shooting Followings are not problems Sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode.
26 Before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating Is power supply switch turned on? Power supply switch is not set at ON.
27 Resumable if lower than 100 degree Error display ( For ERA series ) T r ouble Shooting For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp.
28 Error display ( For EAA series ) T r ouble Shooting For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 15 17 18 19 20 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp. sensor failure Outdoor coil temp.
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Haier AC282AFERA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Haier AC282AFERA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Haier AC282AFERA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Haier AC282AFERA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Haier AC282AFERA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Haier AC282AFERA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Haier AC282AFERA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Haier AC282AFERA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.