Manuale d’uso / di manutenzione del prodotto 309098F del fabbricante Graco
Vai alla pagina of 16
309098F ENG First choice when quality counts. t Part No. 243159 INSTRUCTIONS–P ARTS LIST INSTRUCTIONS This manual contains important warnings and information.
2 309098 W ARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before you operate this equipment.
3 309098 TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container .
4 309098 Unpacking Unpacking the Product The Dynastar r pump module was carefully packaged for shipment by Graco. When the package arrives, perform the following procedure to unpack the units: 1. Inspect the shipping box carefully for shipping damage.
5 309098 Installation Reservoir Mount reservoir [Fig. 2, item (P)] on sturdy flat surface with 6, 3/8 in. diameter bolts. Note location of fill port (K), hydraulic lines, and lubricant outlet port (G) for easy access once installed. Hydraulic system must depressurized before connecting high pressure hydraulic supply line.
6 309098 Installation T ypical Installation The installation shown in Figs. 2, 4, and 5 are only a guide for selecting and installing system components.
7 309098 Fig. 3 V ent V alve Installation Kit (243170) KEY A Hydraulic control line B V ent valve C Pump output connection line D Pressure relief valve E Lubricant output F V ent line A 9647A B C D E F Fig.
8 309098 Installation Fig. 5 9653A V ent return port 1/2” npt (f) V ent valve bracket weld locations Pump mounting ∅ .343 or 5/16–18 (4X) Control module ∅ .
9 309098 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD T o reduce the risk of serious injury , in- cluding fluid injection or splashing in the eyes or on the skin, always follow the Pr.
10 309098 Operation Shut Down. 1. For normal system shut down, disconnect power to lubricator controller (J) by turning off the ignition switch, and turn off hydraulic supply by closing the ball valve (Fig. 2, item AA). CAUTION Never allow the pump to run dry of the fluid being pumped.
11 309098 Parts Drawing 1 3c 3d 3e 3f 3g 3h 3a 7 5 8 9652B Pump hydraulic outlet Pump hydraulic inlet Pump lubricant outlet 3i.
12 309098 Parts Drawing 2a 2d 2p 2e 2q 2j 2k 2m 3a 3b 2f 2b 4a 4n 4j 4r 4m 4q 4p 4k 4d 4e 4c 4h 4g 4f 6 5 2c 2g 2h 2i 4b 2n 9652B T o pump hydraulic inlet T o pump hydraulic outlet T o pump lubricant .
13 309098 Parts List Model 243159, Dynastar Pump Module includes items 1 – 8 *Model 243502, 35# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 *Model 243503, 120# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 *Model 243504, 400# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 Ref.
14 309098 T echnical Data Maximum hydraulic input pressure 3500 psi (241 bar , 24 MPa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump wetted parts See manual 308156 . . . . . . . . . . . . . . . . . .
15 309098 Hydraulic Control Module Circuit: 243501 Does not include pump and pump valve kit..
16 309098 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 309098F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 309098F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 309098F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 309098F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 309098F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 309098F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 309098F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 309098F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.